An Efficient Narrowband Near‐Infrared at 1040 nm Organic Photodetector Realized by Intermolecular Charge Transfer Mediated Coupling Based on a Squaraine Dye
Open accessThe DOI matches its Crossref record; 5 of the 5 references it cites were found in a registry or an index.
Abstract
A highly sensitive short‐wave infrared (SWIR, λ > 1000 nm) organic photodiode (OPD) is described based on a well‐organized nanocrystalline bulk‐heterojunction (BHJ) active layer composed of a dicyanovinyl‐functionalized squaraine dye (SQ‐H) donor material in combination with PC 61 BM. Through thermal annealing, dipolar SQ‐H chromophores self‐assemble in a nanoscale structure with intermolecular charge transfer mediated coupling, resulting in a redshifted and narrow absorption band at 1040 nm as well as enhanced charge carrier mobility. The optimized OPD exhibits an external quantum efficiency (EQE) of 12.3% and a full‐width at half‐maximum of only 85 nm (815 cm−1) at 1050 nm under 0 V, which is the first efficient SWIR OPD based on J‐type aggregates. Photoplethysmography application for heart‐rate monitoring is successfully demonstrated on flexible substrates without applying reverse bias, indicating the potential of OPDs based on short‐range coupled dye aggregates for low‐power operating wearable applications.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Hestand, N. J., & Spano, F. C. (2017) · Accounts of Chemical Research · doi:10.1021/acs.accounts.6b00576 · Cited by 711
Self-citationJ -Aggregates of Cyanine Dye for NIR-II in Vivo Dynamic Vascular Imaging beyond 1500 nm
Sun, C., Li, B., Zhao, M., Wang, S., Lei, Z., Lu, L., Zhang, H., Feng, L., Dou, C., Yin, D., et al. (2019) · Journal of the American Chemical Society · doi:10.1021/jacs.9b10043 · Cited by 582
A flexible organic reflectance oximeter array
Khan, Y., Han, D., Pierre, A., Ting, J., Wang, X., Lochner, C. M., Bovo, G., Yaacobi-Gross, N., Newsome, C., Wilson, R., et al. (2018) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1813053115 · Cited by 278
Organic Multi-Channel Optoelectronic Sensors for Wearable Health Monitoring
Khan, Y., Han, D., Ting, J., Ahmed, M., Nagisetty, R., & Arias, A. C. (2019) · IEEE Access · doi:10.1109/access.2019.2939798 · Cited by 111
Liess, A., Arjona‐Esteban, A., Kudzus, A., Albert, J., Krause, A., Lv, A., Stolte, M., Meerholz, K., & Würthner, F. (2019) · Advanced Functional Materials · doi:10.1002/adfm.201805058 · Cited by 93
Self-citation
Cited by
Design strategies and applications of cyanine dyes in phototherapy
Yuan, J., Yang, H., Huang, W., Liu, S., Zhang, H., Zhang, X., & Peng, X. (2025) · Chemical Society Reviews · doi:10.1039/d3cs00585b · Cited by 143
Double J-Coupling Strategy for Near Infrared Emitters
Shen, C.-A., Stolte, M., Kim, J. H., Rausch, A., & Würthner, F. (2021) · Journal of the American Chemical Society · doi:10.1021/jacs.1c05934 · Cited by 54
Self-citationLi, R., Zhang, Y., Li, S., Chen, J., Cao, Y., Xing, D., Wang, Y., & Huang, F. (2026) · Advanced Functional Materials · doi:10.1002/adfm.202532119 · Cited by 4
Metadata
- Authors
- Kim, J. H., Liess, A., Stolte, M., Krause, A., Stepanenko, V., Zhong, C., Bialas, D., Spano, F., & Würthner, F.
- Venue
- Advanced Materials
- Publisher
- Wiley
- Published
- 2021-05-31
- Volume
- 33
- Issue
- 26
- Pages
- e2100582-e2100582
- ISSN
- 0935-9648 (ISSN-L)
- 1521-4095
- OpenAlex
- W3165343042
- Cited by
- 174
- References
- 5
- FWCI
- 8.35
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.