Organic Multi-Channel Optoelectronic Sensors for Wearable Health Monitoring

Open access
Khan, Yasser, Han, Donggeon, Ting, Jonathan, Ahmed, Maruf, Nagisetty, Ramune, Arias, Ana C.·2019·IEEE Access

Abstract

Recent progress in printed optoelectronics and their integration in wearable sensors have created new avenues for research in reflectance photoplethysmography (PPG) and oximetry. The reflection-mode sensor, which consists of light emitters and detectors, is a vital component of reflectance oximeters. Here, we report a systematic study of the reflectance oximeter sensor design in terms of component geometry, light emitter and detector spacing, and the use of an optical barrier between the emitter and the detector to maximize sensor performance. Printed red and near-infrared (NIR) organic light-emitting diodes (OLEDs) and organic photodiodes (OPDs) are used to design three sensor geometries: (1) Rectangular geometry, where square OLEDs are placed at each side of the OPD; (2) Bracket geometry, where the OLEDs are shaped as brackets and placed around the square OPD; (3) Circular geometry, where the OLEDs are shaped as block arcs and placed around the circular OPD. Utilizing the bracket geometry, we observe 39.7% and 18.2% improvement in PPG signal magnitude in the red and NIR channels compared to the rectangular geometry, respectively. Using the circular geometry, we observe 48.6% and 9.2% improvements in the red and NIR channels compared to the rectangular geometry. Furthermore, a wearable two-channel PPG sensor is utilized to add redundancy to the measurement. Finally, inverse-variance weighting and template matching algorithms are implemented to improve the detection of heart rate from the multi-channel PPG signals.

Integrity signals

Registry

Crossref · 10.1109/access.2019.2939798

Cites

36 of 36 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Claims the paper makes

We couldn’t retrieve this paper’s full text, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

  • The PPG signal amplitude at the upper wrist is lower than that at other sites, such as the underside of the wrist.

    “Second, the signal amplitude at the upper wrist is lower than that at other sites, such as the underside of the wrist [55].”

    From Wearable Photoplethysmography for Cardiovascular Monitoring (2022) · cites this paper as [55]

  • PPG signals can be expressed in Volts, with the pulsatile component of the order of 1 mV in amplitude, although lower amplitudes can be caused by technical factors such as inappropriate gain control or physiological factors such as vasoconstriction.

    “In this case, the pulsatile component of the PPG can be of the order of 1 mV in amplitude [55] although lower amplitudes can be caused by technical factors, such as inappropriate gain control, or physiological factors, such as vasoconstriction [9].”

    From Wearable Photoplethysmography for Cardiovascular Monitoring (2022) · cites this paper as [55]

  • The configuration of a PPG sensor has a large impact on PPG signal quality.

    “The configuration of a PPG sensor has a large impact on the PPG signal quality.”

    From Wearable Photoplethysmography for Cardiovascular Monitoring (2022) · cites this paper as [55]

  • Configurations in which LEDs surround the photodiode result in higher PPG signal amplitudes.

    “Key considerations include [55] the geometry of LED and photodiode positioning, since configurations in which LEDs surround the photodiode result in higher PPG signal amplitudes, the spacing between an LED and the photodiode, since a shorter spacing results in higher amplitudes, and the use of an optical barrier between the LED(s) and photodiode, which can increase the signal amplitude.”

    From Wearable Photoplethysmography for Cardiovascular Monitoring (2022) · cites this paper as [55]

  • A shorter spacing between an LED and the photodiode results in higher PPG signal amplitudes.

    “Key considerations include [55] the geometry of LED and photodiode positioning, since configurations in which LEDs surround the photodiode result in higher PPG signal amplitudes, the spacing between an LED and the photodiode, since a shorter spacing results in higher amplitudes, and the use of an optical barrier between the LED(s) and photodiode, which can increase the signal amplitude.”

    From Wearable Photoplethysmography for Cardiovascular Monitoring (2022) · cites this paper as [55]

Cites

Flagged first, then by citations

4 of the 40 references couldn’t be matched to a known paper.

Cited by

Sorted by citations

Authors
Khan, Y., Han, D., Ting, J., Ahmed, M., Nagisetty, R., & Arias, A. C.
Affiliations
  • University of California, Berkeley (US)
  • Intel (United States) (US)
Venue
IEEE Access
Published
2019
Volume
7
Pages
128114-128124
ISSN
2169-3536 (ISSN-L)
OpenAlex
W2971855146
Cited by
111
References
40
Citations by year
2026: 8 · 2025: 15 · 2024: 24 · 2023: 14 · 2022: 19 · 2021: 21 · 2020: 9 · 2019: 1
FWCI
4.39
Type
journal article
Language
en
Open access
Locations
  • IEEE Access (publishedVersion, cc-by)
  • DOAJ (DOAJ: Directory of Open Access Journals) (submittedVersion, cc-by-sa)
Funders
  • Semiconductor Research Corporation (2014-IN-2571)
  • Cambridge Display Technology Limited (02672530)
  • FlexTech (AFOSR-42299)
Topics
  • Physical Sciences › Engineering › Biomedical Engineering › Non-Invasive Vital Sign Monitoring
  • Physical Sciences › Engineering › Biomedical Engineering › Advanced Sensor and Energy Harvesting Materials
  • Physical Sciences › Engineering › Electrical and Electronic Engineering › Organic Electronics and Photovoltaics
Keywords
wearable health monitoring, organic light-emitting diodes, organic photodiodes, sensor geometry, optical barrier, near-infrared sensing, heartbeat detection, inverse variance weighting, template matching, sensor redundancy

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review