Smart Face Mask Based on an Ultrathin Pressure Sensor for Wireless Monitoring of Breath Conditions
The DOI matches its Crossref record; 7 of the 7 references it cites were found in a registry or an index.
Abstract
A smart face mask that can conveniently monitor breath information is beneficial for maintaining personal health and preventing the spread of diseases. However, some challenges still need to be addressed before such devices can be of practical use. One key challenge is to develop a pressure sensor that is easily triggered by low pressure and has excellent stability as well as electrical and mechanical properties. In this study, a wireless smart face mask is designed by integrating an ultrathin self‐powered pressure sensor and a compact readout circuit with a normal face mask. The pressure sensor is the thinnest (totally compressed thickness of ≈5.5 µm) and lightest (total weight of ≈4.5 mg) electrostatic pressure sensor capable of achieving a peak open‐circuit voltage of up to ≈10 V when stimulated by airflow, which endows the sensor with the advantage of readout circuit miniaturization and makes the breath‐monitoring system portable and wearable. To demonstrate the capabilities of the smart face mask, it is used to wirelessly measure and analyze the various breath conditions of multiple testers.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Projecting the transmission dynamics of SARS-CoV-2 through the postpandemic period
Kissler, S. M., Tedijanto, C., Goldstein, E., Grad, Y. H., & Lipsitch, M. (2020) · Science · doi:10.1126/science.abb5793 · Cited by 2,611
Inflammation-free, gas-permeable, lightweight, stretchable on-skin electronics with nanomeshes
Miyamoto, A., Lee, S., Cooray, N. F., Lee, S., Mori, M., Matsuhisa, N., Jin, H., Yoda, L., Yokota, T., Itoh, A., et al. (2017) · Nature Nanotechnology · doi:10.1038/nnano.2017.125 · Cited by 1,181
Self-citationObstructive Sleep Apnea Syndrome in the Sao Paulo Epidemiologic Sleep Study
Tufik, S., Santos-Silva, R., Taddei, J. A., & Bittencourt, L. R. A. (2010) · Sleep Medicine · doi:10.1016/j.sleep.2009.10.005 · Cited by 1,069
Ma, Y., Liu, N., Li, L., Hu, X., Zou, Z., Wang, J., Luo, S., & Gao, Y. (2017) · Nature Communications · doi:10.1038/s41467-017-01136-9 · Cited by 788
Paper‐Based Electrical Respiration Sensor
Güder, F., Ainla, A., Redston, J., Mosadegh, B., Glavan, A., Martin, T. J., & Whitesides, G. M. (2016) · Angewandte Chemie International Edition · doi:10.1002/anie.201511805 · Cited by 472
Electronic Skin with Multifunction Sensors Based on Thermosensation
Zhao, S., & Zhu, R. (2017) · Advanced Materials · doi:10.1002/adma.201606151 · Cited by 273
Self-powered electro-tactile system for virtual tactile experiences
Shi, Y., Wang, F., Tian, J., Li, S., Fu, E., Nie, J., Lei, R., Ding, Y., Chen, X., & Wang, Z. L. (2021) · Science Advances · doi:10.1126/sciadv.abe2943 · Cited by 251
Self-citation
Cited by
Technology Roadmap for Flexible Sensors
Luo, Y., Abidian, M. R., Ahn, J.-H., Akinwande, D., Andrews, A. M., Antonietti, M., Bao, Z., Berggren, M., Berkey, C. A., Bettinger, C. J., et al. (2023) · ACS Nano · doi:10.1021/acsnano.2c12606 · Cited by 1,383
Self-citationLiu, S., Li, W., Wang, X., Lu, L., Yao, Y., Lai, S., Xu, Y., Yang, J., Hu, Z., Gong, X., et al. (2025) · ACS Nano · doi:10.1021/acsnano.4c13458 · Cited by 64
Metadata
- Authors
- Zhong, J., Li, Z., Takakuwa, M., Inoue, D., Hashizume, D., Jiang, Z., Shi, Y., Ou, L., Nayeem, M. O. G., Umezu, S., Fukuda, K., & Someya, T.
- Venue
- Advanced Materials
- Publisher
- Wiley
- Published
- 2021-11-30
- Volume
- 34
- Issue
- 6
- Pages
- e2107758-e2107758
- ISSN
- 0935-9648 (ISSN-L)
- 1521-4095
- OpenAlex
- W3210966796
- Cited by
- 178
- References
- 7
- FWCI
- 9.24
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.