Plasmonic Fluorescence Enhancement in Diagnostics for Clinical Tests at Point‐of‐Care: A Review of Recent Technologies
Open accessThe DOI matches its Crossref record; 5 of the 5 references it cites were found in a registry or an index.
Abstract
Fluorescence‐based biosensors have widely been used in the life‐sciences and biomedical applications due to their low limit of detection and a diverse selection of fluorophores that enable simultaneous measurements of multiple biomarkers. Recent research effort has been made to implement fluorescent biosensors into the exploding field of point‐of‐care testing (POCT), which uses cost‐effective strategies for rapid and affordable diagnostic testing. However, fluorescence‐based assays often suffer from their feeble signal at low analyte concentrations, which often requires sophisticated, costly, and bulky instrumentation to maintain high detection sensitivity. Metal‐ and metal oxide‐based nanostructures offer a simple solution to increase the output signal from fluorescent biosensors due to the generation of high field enhancements close to a metal or metal oxide surface, which has been shown to improve the excitation rate, quantum yield, photostability, and radiation pattern of fluorophores. This article provides an overview of existing biosensors that employ various strategies for fluorescence enhancement via nanostructures and have demonstrated the potential for use as POCT. Biosensors using nanostructures such as planar substrates, freestanding nanoparticles, and metal–dielectric–metal nanocavities are discussed with an emphasis placed on technologies that have shown promise towards POCT applications without the need for centralized laboratories.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
U1 snRNP regulates cancer cell migration and invasion in vitro
Oh, J.-M., Venters, C. C., Di, C., Pinto, A. M., Wan, L., Younis, I., Cai, Z., Arai, C., So, B. R., Duan, J., et al. (2020) · Nature Communications · doi:10.1038/s41467-019-13993-7 · Cited by 7,157
Haes, A. J., & Van Duyne, R. P. (2002) · Journal of the American Chemical Society · doi:10.1021/ja020393x · Cited by 2,057
Variation of the Fluorescence Decay Time of a Molecule in Front of a Mirror
Drexhage, K. H., Kuhn, H., & Schäfer, F. P. (1968) · Berichte der Bunsengesellschaft für physikalische Chemie · doi:10.1002/bbpc.19680720261 · Cited by 260
Label-Free Plasmonic Biosensors for Point-of-Care Diagnostics: A Review
Soler, M., Huertas, C. S., & Lechuga, L. M. (2019) · Expert Review of Molecular Diagnostics · doi:10.1080/14737159.2019.1554435 · Cited by 236
Yan, T., Zhang, G., Chai, H., Qu, L., & Zhang, X. (2021) · Frontiers in Bioengineering and Biotechnology · doi:10.3389/fbioe.2021.753692 · Cited by 59
Cited by
Truong, T. T., Mondal, S., Doan, V. H. M., Tak, S., Choi, J., Oh, H., Nguyen, T. D., Misra, M., Lee, B., & Oh, J. (2024) · Advances in Colloid and Interface Science · doi:10.1016/j.cis.2024.103263 · Cited by 185
Metadata
- Authors
- Semeniak, D., Cruz, D. F., Chilkoti, A., & Mikkelsen, M. H.
- Venue
- Advanced Materials
- Publisher
- Wiley
- Published
- 2022-04-24
- Volume
- 35
- Issue
- 34
- Pages
- e2107986-e2107986
- ISSN
- 0935-9648 (ISSN-L)
- 1521-4095
- OpenAlex
- W4220880413
- Cited by
- 184
- References
- 5
- FWCI
- 9.98
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Plasmonic Fluorescence Enhancement in Diagnostics for Clinical Tests at Point‐of‐Care: A Review of Recent Technologies. https://app.cochat.ai/papers/10.1002/adma.202107986
- The paper
- Semeniak, D., Cruz, D. F., Chilkoti, A., & Mikkelsen, M. H. (2023). Plasmonic Fluorescence Enhancement in Diagnostics for Clinical Tests at Point‐of‐Care: A Review of Recent Technologies. Advanced Materials. https://doi.org/10.1002/adma.202107986
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.