Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 278

The DOI matches its Crossref record; 47 of the 47 references it cites were found in a registry or an index.

Clinical Validation of a Wearable Piezoelectric Blood‐Pressure Sensor for Continuous Health Monitoring

Min, Seongwook, Kim, Dong Hyun, Joe, Daniel J., Kim, Byung Woo, Jung, Young Hoon, Lee, Jae Hee, Lee, Bo‐Yeon, Doh, Il, An, Jaehun, Youn, Young‐Nam, Joung, Boyoung, Yoo, Chang D., Ahn, Hyo‐Suk, Lee, Keon Jae·2023·Advanced Materials

Abstract

Wearable blood‐pressure sensors have recently attracted attention as healthcare devices for continuous non‐invasive arterial pressure (CNAP) monitoring. However, the accuracy of wearable blood‐pressure (BP) monitoring devices has been controversial due to the low signal quality of sensors, the absence of an accurate transfer function to convert the sensor signals into BP values, and the lack of clinical validation regarding measurement precision. Here, a wearable piezoelectric blood‐pressure sensor (WPBPS) is reported, which achieves a high normalized sensitivity (0.062 kPa−1), and fast response time (23 ms) for CNAP monitoring. The transfer function of a linear regression model is designed, offering a simple solution to convert the flexible piezoelectric sensor signals into BP values. In order to verify the measurement accuracy of WPBPS, clinical trials are performed on 35 subjects aged from 20 to 80 s after screening. The mean difference between the WPBPS and a commercial sphygmomanometer of 175 BP data pairs is −0.89 ± 6.19 and −0.32 ± 5.28 mmHg for systolic blood pressure (SBP) and diastolic blood pressure (DBP), respectively. By building a WPBPS‐embedded wristwatch, the potentially promising use of a convenient, portable, continuous BP monitoring system for cardiovascular disease diagnosis is demonstrated.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1002/adma.202301627

Cites

47 of 47 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 47 references

Metadata

Authors
Min, S., Kim, D. H., Joe, D. J., Kim, B. W., Jung, Y. H., Lee, J. H., Lee, B., Doh, I., An, J., Youn, Y., Joung, B., Yoo, C. D., Ahn, H., & Lee, K. J.
Venue
Advanced Materials
Publisher
Wiley
Published
2023-05-11
Volume
35
Issue
26
Pages
e2301627-e2301627
ISSN
  • 0935-9648 (ISSN-L)
  • 1521-4095
OpenAlex
W4360814289
Cited by
278
References
47
FWCI
20.39
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Clinical Validation of a Wearable Piezoelectric Blood‐Pressure Sensor for Continuous Health Monitoring. https://app.cochat.ai/papers/10.1002/adma.202301627
The paper
Min, S., Kim, D. H., Joe, D. J., Kim, B. W., Jung, Y. H., Lee, J. H., Lee, B., Doh, I., An, J., Youn, Y., Joung, B., Yoo, C. D., Ahn, H., & Lee, K. J. (2023). Clinical Validation of a Wearable Piezoelectric Blood‐Pressure Sensor for Continuous Health Monitoring. Advanced Materials. https://doi.org/10.1002/adma.202301627

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.