Clinical Validation of a Wearable Piezoelectric Blood‐Pressure Sensor for Continuous Health Monitoring
Abstract
Wearable blood‐pressure sensors have recently attracted attention as healthcare devices for continuous non‐invasive arterial pressure (CNAP) monitoring. However, the accuracy of wearable blood‐pressure (BP) monitoring devices has been controversial due to the low signal quality of sensors, the absence of an accurate transfer function to convert the sensor signals into BP values, and the lack of clinical validation regarding measurement precision. Here, a wearable piezoelectric blood‐pressure sensor (WPBPS) is reported, which achieves a high normalized sensitivity (0.062 kPa−1), and fast response time (23 ms) for CNAP monitoring. The transfer function of a linear regression model is designed, offering a simple solution to convert the flexible piezoelectric sensor signals into BP values. In order to verify the measurement accuracy of WPBPS, clinical trials are performed on 35 subjects aged from 20 to 80 s after screening. The mean difference between the WPBPS and a commercial sphygmomanometer of 175 BP data pairs is −0.89 ± 6.19 and −0.32 ± 5.28 mmHg for systolic blood pressure (SBP) and diastolic blood pressure (DBP), respectively. By building a WPBPS‐embedded wristwatch, the potentially promising use of a convenient, portable, continuous BP monitoring system for cardiovascular disease diagnosis is demonstrated.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Ettehad, D., Emdin, C. A., Kiran, A., Anderson, S. G., Callender, T., Emberson, J., Chalmers, J., Rodgers, A., & Rahimi, K. (2016) · The Lancet · doi:10.1016/s0140-6736(15)01225-8 · Cited by 3,755
Bunney, P. E., Zink, A. N., Holm, A. A., Billington, C. J., & Kotz, C. M. (2017) · Physiology & Behavior · doi:10.1016/j.physbeh.2017.03.040 · Cited by 2,104
High blood pressure and cardiovascular disease
Fuchs, F. D., & Whelton, P. K. (2020) · Hypertension · doi:10.1161/hypertensionaha.119.14240 · Cited by 1,948
Wearable sensors: modalities, challenges, and prospects
Heikenfeld, J., Jajack, A., Rogers, J., Gutruf, P., Tian, L., Pan, T., Li, R., Khine, M., Kim, J., Wang, J., et al. (2018) · Lab on a Chip · doi:10.1039/c7lc00914c · Cited by 1,434
European Society of Hypertension practice guidelines for ambulatory blood pressure monitoring
Parati, G., Stergiou, G., O’Brien, E., Asmar, R., Beilin, L., Bilo, G., Clement, D., de la Sierra, A., de Leeuw, P., Dolan, E., et al. (2014) · Journal of Hypertension · doi:10.1097/hjh.0000000000000221 · Cited by 1,021
Dagdeviren, C., Su, Y., Joe, P., Yona, R., Liu, Y., Kim, Y.-S., Huang, Y., Damadoran, A. R., Xia, J., Martin, L. W., et al. (2014) · Nature Communications · doi:10.1038/ncomms5496 · Cited by 987
Global Brief on Hypertension: Silent Killer, Global Public Health Crisis
Haldar, R. N. (2013) · Indian Journal of Physical Medicine and Rehabilitation · doi:10.5005/ijopmr-24-1-2 · Cited by 942
Olsen, M. H., Angell, S. Y., Asma, S., Boutouyrie, P., Burger, D., Chirinos, J. A., Damasceno, A., Delles, C., Gimenez-Roqueplo, A.-P., Hering, D., et al. (2016) · The Lancet · doi:10.1016/s0140-6736(16)31134-5 · Cited by 939
Monitoring of the central blood pressure waveform via a conformal ultrasonic device
Wang, C., Li, X., Hu, H., Zhang, L., Huang, Z., Lin, M., Zhang, Z., Yin, Z., Huang, B., Gong, H., et al. (2018) · Nature Biomedical Engineering · doi:10.1038/s41551-018-0287-x · Cited by 895
Highly‐Efficient, Flexible Piezoelectric PZT Thin Film Nanogenerator on Plastic Substrates
Park, K., Son, J. H., Hwang, G., Jeong, C. K., Ryu, J., Koo, M., Choi, I., Lee, S. H., Byun, M., Wang, Z. L., et al. (2014) · Advanced Materials · doi:10.1002/adma.201305659 · Cited by 835
Self-citationSelf‐Powered Real‐Time Arterial Pulse Monitoring Using Ultrathin Epidermal Piezoelectric Sensors
Park, D. Y., Joe, D. J., Kim, D. H., Park, H., Han, J. H., Jeong, C. K., Park, H., Park, J. G., Joung, B., & Lee, K. J. (2017) · Advanced Materials · doi:10.1002/adma.201702308 · Cited by 691
Self-citationInvestigating sources of inaccuracy in wearable optical heart rate sensors
Bent, B., Goldstein, B. A., Kibbe, W. A., & Dunn, J. P. (2020) · npj Digital Medicine · doi:10.1038/s41746-020-0226-6 · Cited by 673
An epidermal patch for the simultaneous monitoring of haemodynamic and metabolic biomarkers
Sempionatto, J. R., Lin, M., Yin, L., De la paz, E., Pei, K., Sonsa-ard, T., de Loyola Silva, A. N., Khorshed, A. A., Zhang, F., Tostado, N., et al. (2021) · Nature Biomedical Engineering · doi:10.1038/s41551-021-00685-1 · Cited by 658
O'Rourke, M. F., Pauca, A., & Jiang, X. (2001) · British Journal of Clinical Pharmacology · doi:10.1046/j.0306-5251.2001.01400.x · Cited by 640
O'Brien, E., Atkins, N., Stergiou, G., Karpettas, N., Parati, G., Asmar, R., Imai, Y., Wang, J., Mengden, T., & Shennan, A. (2010) · Blood Pressure Monitoring · doi:10.1097/mbp.0b013e3283360e98 · Cited by 610
Pinto Lima, A., Beelen, P., & Bakker, J. (2002) · Critical Care Medicine · doi:10.1097/00003246-200206000-00006 · Cited by 476
Stergiou, G. S., Alpert, B., Mieke, S., Asmar, R., Atkins, N., Eckert, S., Frick, G., Friedman, B., Graßl, T., Ichikawa, T., et al. (2018) · Hypertension · doi:10.1161/hypertensionaha.117.10237 · Cited by 469
Sample Size Estimation in Clinical Research
Wang, X., & Ji, X. (2020) · Chest · doi:10.1016/j.chest.2020.03.010 · Cited by 452
Sources of inaccuracy in photoplethysmography for continuous cardiovascular monitoring
Fine, J., Branan, K. L., Rodriguez, A. J., Boonya-ananta, T., Ajmal, Ramella-Roman, J. C., McShane, M. J., & Coté, G. L. (2021) · Biosensors · doi:10.3390/bios11040126 · Cited by 348
Avolio, A. P., Butlin, M., & Walsh, A. (2010) · Physiological Measurement · doi:10.1088/0967-3334/31/1/r01 · Cited by 310
Noninvasive Assessment of the Digital Volume Pulse: Comparison With the Peripheral Pressure Pulse
Millasseau, S. C., Guigui, F. G., Kelly, R. P., Prasad, K., Cockcroft, J. R., Ritter, J. M., & Chowienczyk, P. J. (2000) · Hypertension · doi:10.1161/01.hyp.36.6.952 · Cited by 294
Piezoelectric Dynamics of Arterial Pulse for Wearable Continuous Blood Pressure Monitoring
Yi, Z., Liu, Z., Li, W., Ruan, T., Chen, X., Liu, J., Yang, B., & Zhang, W. (2022) · Advanced Materials · doi:10.1002/adma.202110291 · Cited by 265
Soft Wearable Pressure Sensors for Beat‐to‐Beat Blood Pressure Monitoring
Kim, J., Chou, E., Le, J., Wong, S., Chu, M., & Khine, M. (2019) · Advanced Healthcare Materials · doi:10.1002/adhm.201900109 · Cited by 238
Wang, H. S., Hong, S. K., Han, J. H., Jung, Y. H., Jeong, H. K., Im, T. H., Jeong, C. K., Lee, B.-Y., Kim, G., Yoo, C. D., et al. (2021) · Science Advances · doi:10.1126/sciadv.abe5683 · Cited by 219
Self-citationAccuracy of a continuous blood pressure monitor based on arterial tonometry.
Sato, T., Nishinaga, M., Kawamoto, A., Ozawa, T., & Takatsuji, H. (1993) · Hypertension · doi:10.1161/01.hyp.21.6.866 · Cited by 217
Flexible piezoelectric devices for gastrointestinal motility sensing
Dagdeviren, C., Javid, F., Joe, P., von Erlach, T., Bensel, T., Wei, Z., Saxton, S., Cleveland, C., Booth, L., McDonnell, S., et al. (2017) · Nature Biomedical Engineering · doi:10.1038/s41551-017-0140-7 · Cited by 194
Advances in self-powered triboelectric pressure sensors
Lei, H., Chen, Y., Gao, Z., Wen, Z., & Sun, X. (2021) · Journal of Materials Chemistry A · doi:10.1039/d1ta03505c · Cited by 181
Needle-shaped ultrathin piezoelectric microsystem for guided tissue targeting via mechanical sensing
Yu, X., Wang, H., Ning, X., Sun, R., Albadawi, H., Salomao, M. A., Silva, A. C., Yu, Y., Tian, L., Koh, A., et al. (2018) · Nature Biomedical Engineering · doi:10.1038/s41551-018-0201-6 · Cited by 161
Ambulatory blood pressure monitoring in Australia: 2011 consensus position statement
Head, G. A., McGrath, B. P., Mihailidou, A. S., Nelson, M. R., Schlaich, M. P., Stowasser, M., Mangoni, A. A., Cowley, D., Brown, M. A., Ruta, L., et al. (2011) · Journal of Hypertension · doi:10.1097/hjh.0b013e32834de621 · Cited by 140
Han, J. H., Kwak, J.-H., Joe, D. J., Hong, S. K., Wang, H. S., Park, J. H., Hur, S., & Lee, K. J. (2018) · Nano Energy · doi:10.1016/j.nanoen.2018.08.053 · Cited by 128
Self-citationde la Sierra, A., Banegas, J. R., Segura, J., Gorostidi, M., & Ruilope, L. M. (2012) · Journal of Hypertension · doi:10.1097/hjh.0b013e328350bb40 · Cited by 110
Elevated blood pressure and risk of aortic valve disease: a cohort analysis of 5.4 million UK adults
Rahimi, K., Mohseni, H., Kiran, A., Tran, J., Nazarzadeh, M., Rahimian, F., Woodward, M., Dwyer, T., MacMahon, S. W., & Otto, C. M. (2018) · European Heart Journal · doi:10.1093/eurheartj/ehy486 · Cited by 106
Chun, K., Seo, S., & Han, C. (2022) · Advanced Materials · doi:10.1002/adma.202110082 · Cited by 97
Self-powered flexible electronics beyond thermal limits
Park, J. H., Lee, H. E., Jeong, C. K., Kim, D. H., Hong, S. K., Park, K., & Lee, K. J. (2018) · Nano Energy · doi:10.1016/j.nanoen.2018.11.077 · Cited by 91
Self-citationHope, S. A., Tay, D. B. H., Meredith, I. T., & Cameron, J. D. (2002) · American Journal of Physiology-Heart and Circulatory Physiology · doi:10.1152/ajpheart.00216.2002 · Cited by 89
Sieciński, S., Kostka, P., & Tkacz, E. (2020) · Sensors · doi:10.3390/s20164522 · Cited by 86
James, G. D., & Gerber, L. M. (2017) · American Journal of Human Biology · doi:10.1002/ajhb.23063 · Cited by 68
Validation of a wearable cuff-less wristwatch-type blood pressure monitoring device
Moon, J. H., Kang, M.-K., Choi, C.-E., Min, J., Lee, H., & Lim, S. K. (2020) · Scientific Reports · doi:10.1038/s41598-020-75892-y · Cited by 58
Sugimachi, M., Shishido, T., Miyatake, K., & Sunagawa, K. (2001) · The Japanese Journal of Physiology · doi:10.2170/jjphysiol.51.217 · Cited by 47
Simultaneous piezoelectric noninvasive detection of multiple vital signs
Allataifeh, A., & Ahmad, M. A. (2020) · Scientific Reports · doi:10.1038/s41598-019-57326-6 · Cited by 43
Design, development and clinical validation of a wrist-based optical heart rate monitor
Preejith, S. P., Alex, A., Joseph, J., & Sivaprakasam, M. (2016) · 2016 IEEE International Symposium on Medical Measurements and Applications (MeMeA) · doi:10.1109/memea.2016.7533786 · Cited by 41
Arterial Aging: A Review of the Pathophysiology and Potential for PharmacologicalIntervention
O’Rourke, M. F., Adji, A. I., Namasivayam, M. J., & Mok, J. (2011) · Drugs & Aging · doi:10.2165/11592730-000000000-00000 · Cited by 27
The Advent of Cuffless Mobile Device Blood Pressure Measurement: Remaining Challenges and Pitfalls
Lee, H., & Burkard, T. (2022) · Korean Circulation Journal · doi:10.4070/kcj.2021.0405 · Cited by 14
Calibration of oscillometric non-invasive devices for monitoring blood pressure
Doh, I., Lim, H. K., & Ahn, B. (2015) · Metrologia · doi:10.1088/0026-1394/52/2/291 · Cited by 10
Self-citationTakahashi, H., & Saito, K. (2020) · Vascular Health and Risk Management · doi:10.2147/vhrm.s287016 · Cited by 9
Poli, A., Cosoli, G., Iadarola, G., Spinsante, S., & Scalise, L. (2022) · IEEE International Symposium on Medical Measurements and Applications (MeMeA) · doi:10.1109/memea54994.2022.9856533 · Cited by 6
Metadata
- Authors
- Min, S., Kim, D. H., Joe, D. J., Kim, B. W., Jung, Y. H., Lee, J. H., Lee, B., Doh, I., An, J., Youn, Y., Joung, B., Yoo, C. D., Ahn, H., & Lee, K. J.
- Venue
- Advanced Materials
- Publisher
- Wiley
- Published
- 2023-05-11
- Volume
- 35
- Issue
- 26
- Pages
- e2301627-e2301627
- ISSN
- 0935-9648 (ISSN-L)
- 1521-4095
- OpenAlex
- W4360814289
- Cited by
- 278
- References
- 47
- FWCI
- 20.39
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.