Student or educator? Sign up with your school email and get 6 months of Pro free.

The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.

European Society of Hypertension practice guidelines for ambulatory blood pressure monitoring

Abstract

Given the increasing use of ambulatory blood pressure monitoring (ABPM) in both clinical practice and hypertension research, a group of scientists, participating in the European Society of Hypertension Working Group on blood pressure monitoring and cardiovascular variability, in year 2013 published a comprehensive position paper dealing with all aspects of the technique, based on the available scientific evidence for ABPM. The present work represents an updated schematic summary of the most important aspects related to the use of ABPM in daily practice, and is aimed at providing recommendations for proper use of this technique in a clinical setting by both specialists and practicing physicians. The present article details the requirements and the methodological issues to be addressed for using ABPM in clinical practice, The clinical indications for ABPM suggested by the available studies, among which white-coat phenomena, masked hypertension, and nocturnal hypertension, are outlined in detail, and the place of home measurement of blood pressure in relation to ABPM is discussed. The role of ABPM in pharmacological, epidemiological, and clinical research is also briefly mentioned. Finally, the implementation of ABPM in practice is considered in relation to the situation of different countries with regard to the reimbursement and the availability of ABPM in primary care practices, hospital clinics, and pharmacies.

Overview

Integrity signals

Registry

Crossref · 10.1097/hjh.0000000000000221

Cites

4 of 4 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Verification

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Citations

Cites

Show all 4 references

Cited by

See all 1,021

Metadata

Authors
Parati, G., Stergiou, G., O’Brien, E., Asmar, R., Beilin, L., Bilo, G., Clement, D., de la Sierra, A., de Leeuw, P., Dolan, E., Fagard, R., Graves, J., Head, G. A., Imai, Y., Kario, K., Lurbe, E., Mallion, J.-M., Mancia, G., Mengden, T., Myers, M., Ogedegbe, G., Ohkubo, T., Omboni, S., Palatini, P., Redon, J., Ruilope, L. M., Shennan, A., Staessen, J. A., vanMontfrans, G., Verdecchia, P., Waeber, B., Wang, J., Zanchetti, A., & Zhang, Y.
Affiliations
  • University of Milano-Bicocca (IT)
  • National and Kapodistrian University of Athens (GR)
  • The University of Western Australia (AU)
  • IRCCS Istituto Auxologico Italiano (IT)
  • Ghent University (BE)
  • Connolly Hospital Blanchardstown (IE)
  • KU Leuven (BE)
  • Mayo Clinic (US)
  • Tohoku University (JP)
  • Jichi Medical University (JP)
  • Hospital General Universitario Gregorio Marañón (ES)
  • Université Joseph Fourier (FR)
  • University of Toronto (CA)
  • New York University (US)
  • Teikyo University (JP)
  • Italian Institute of Telemedicine (IT)
  • University of Padua (IT)
  • Universidad Complutense de Madrid (ES)
  • King's College London (GB)
  • Maastricht University (NL)
  • University of Amsterdam (NL)
  • University of Lausanne (CH)
  • University of Milan (IT)
  • Chinese Academy of Medical Sciences & Peking Union Medical College (CN)
Corresponding author
  • Parati, Gianfranco
  • Stergiou, George
Venue
Journal of Hypertension
Published
2014-07
Volume
32
Issue
7
Pages
1359-1366
ISSN
0263-6352 (ISSN-L)
OpenAlex
W2034643992
Cited by
1,021
References
4
Citations by year
2026: 44 · 2025: 47 · 2024: 89 · 2023: 77 · 2022: 113 · 2021: 109 · 2020: 113 · 2019: 123 · 2018: 97 · 2017: 75 · 2016: 62 · 2015: 59 · 2014: 11
FWCI
47.32
Type
journal article
Language
en
Open access
closed
Locations
  • Journal of Hypertension (publishedVersion)
  • PubMed (publishedVersion)
  • UWA Profiles and Research Repository (UWA) (submittedVersion)
  • BOA (University of Milano-Bicocca) (submittedVersion)
  • Research Publications (Maastricht University) (submittedVersion)
  • Institutional Repositories DataBase (IRDB) (submittedVersion)
  • IRIS (submittedVersion)
  • Lirias (KU Leuven) (submittedVersion)
  • SERVAL (Université de Lausanne) (submittedVersion)
Funders
  • European Society of Cardiology
  • National Institutes of Health
  • Japan Society for the Promotion of Science (25253059)
Topics
  • Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Blood Pressure and Hypertension Studies
  • Physical Sciences › Engineering › Biomedical Engineering › Non-Invasive Vital Sign Monitoring
  • Health Sciences › Medicine › Public Health, Environmental and Occupational Health › Clinical practice guidelines implementation
Keywords
ambulatory blood pressure monitoring, hypertension, white coat hypertension, masked hypertension, nocturnal hypertension, home blood pressure monitoring, indications, primary care, cardiovascular variability
MeSH terms
Adolescent, Adult, Atrial Fibrillation, Child, Female, Humans, Hypertension, Male, Obesity, Practice Patterns, Physicians', Software, Blood Pressure Monitoring, Ambulatory, White Coat Hypertension, Masked Hypertension

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: European Society of Hypertension practice guidelines for ambulatory blood pressure monitoring. https://app.cochat.ai/papers/10.1097/hjh.0000000000000221
The paper
Parati, G., Stergiou, G., O’Brien, E., Asmar, R., Beilin, L., Bilo, G., Clement, D., de la Sierra, A., de Leeuw, P., Dolan, E., Fagard, R., Graves, J., Head, G. A., Imai, Y., Kario, K., Lurbe, E., Mallion, J.-M., Mancia, G., Mengden, T., . . . Zhang, Y. (2014). European Society of Hypertension practice guidelines for ambulatory blood pressure monitoring. Journal of Hypertension. https://doi.org/10.1097/hjh.0000000000000221

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.