Cited by 75Quantum Dots Synthesis And PropertiesAdvanced Semiconductor Detectors and MaterialsSemiconductor Quantum Structures and Devices

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Short‐Wave Infrared Colloidal QD Photodetector with Nanosecond Response Times Enabled by Ultrathin Absorber Layers

Open access

Abstract

Ultrafast short‐wavelength infrared (SWIR) photodetection is of great interest for emerging automated vision and spatial mapping technologies. Colloidal quantum dots (QDs) stand out for SWIR photodetection compared to epitaxial (In,Ga)As or (Hg,Cd)Te semiconductors by their combining a size‐tunable bandgap and a suitability for cost‐effective, solution‐based processing. However, achieving ultrafast, nanosecond‐level response time has remained an outstanding challenge for QD‐based SWIR photodiodes (QDPDs). Here, record 4 ns response time in PbS‐based QDPDs that operate at SWIR wavelengths is reported, a result reaching the requirement of SWIR light detection and ranging based on colloidal QDs. These ultrafast QDPDs combine a thin active layer to reduce the carrier transport time and a small area to inhibit slow capacitive discharging. By implementing a concentration gradient ligand exchange method, high‐quality p–n junctions are fabricated in these ultrathin QDPDs. Moreover, these ultrathin QDPDs attain an external quantum efficiency of 42% at 1330 nm, due to a 2.5‐fold enhanced light absorption through the formation of a Fabry–Perot cavity within the QDPD and the highly efficient extraction (98%) of photogenerated charge carriers. Based on these results, it is estimated that a further increase of the charge‐carrier mobility can lead to PbS QDPDs with sub‐nanosecond response time.

Overview

Integrity signals

Registry

Crossref · 10.1002/adma.202402002

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Verification

Claims the paper makes

We couldn’t retrieve this paper’s full text, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Citations

Cites

Flagged first, then by citations

Research works printed but not linked: 34

  1. M. P.Hansen D. S.Malchow presented at Thermosense XXX FL USA 2008 https://doi.org/10.1117/12.777776. · DOI
  2. 10.1515/nanoph-2017-0039 · DOI
  3. 10.1038/s41551-017-0056 · DOI · Paper page
  4. 10.1126/science.aaz8541 · DOI
  5. 10.1038/nphoton.2009.72 · DOI
  6. 10.1002/adma.201702055 · DOI
  7. 10.1038/s41566-019-0362-1 · DOI
  8. 10.1038/ncomms12046 · DOI
  9. 10.1039/D1TC04961E · DOI
  10. 10.1002/adma.202203039 · DOI
  11. 10.1038/s41598-020-59677-x · DOI
  12. 10.1002/advs.202200844 · DOI
  13. J.Lee E.Georgitzikis Y.Li Z.Lin J.Park I.Lieberman D.Cheyns M.Jayapala A.Lambrechts S.Thijs R.Stahl P. E.Malinowski 2020 IEEE Int. Electron Devices Meeting (IEDM) IEEE CA USA2020.
  14. 10.1017/CBO9781139022750 · DOI
  15. 10.1021/nn506223h · DOI
  16. 10.1126/science.aac5523 · DOI
  17. 10.1038/s41528-018-0023-3 · DOI
  18. 10.1021/nn103050w · DOI
  19. 10.1021/acsnano.9b06125 · DOI
  20. 10.1038/nnano.2008.313 · DOI
  21. 10.1016/j.matt.2020.12.017 · DOI · Paper page
  22. 10.1073/pnas.2305327120 · DOI
  23. 10.1002/adma.202306147 · DOI
  24. 10.1021/acsanm.3c02221 · DOI
  25. 10.1038/s41566-023-01345-3 · DOI
  26. 10.1039/C5EE03887A · DOI
  27. 10.1002/adom.202101611 · DOI
  28. 10.1021/acsanm.8b01696 · DOI
  29. 10.1117/1.OE.56.9.097101 · DOI
  30. 10.1126/science.aaa2951 · DOI
  31. 10.1002/adma.201906199 · DOI · Paper page
  32. 10.1021/acsenergylett.6b00403 · DOI
  33. 10.1021/ja510739q · DOI
  34. 10.1021/jp050745x · DOI

Cited by

Sorted by citations

Metadata

Authors
Deng, Y., Pang, C., Kheradmand, E., Leemans, J., Bai, J., Minjauw, M., Liu, J., Molkens, K., Beeckman, J., Detavernier, C., Geiregat, P., Van Thourhout, D., & Hens, Z.
Affiliations
  • Ghent University (BE)
  • Center for Nano and Biophotonics Ghent University Ghent 9052 Belgium
Corresponding author
  • Deng, Yu‐Hao
  • Hens, Zeger
Venue
Advanced Materials
Publisher
Wiley
Published
2024-05-03
Volume
36
Issue
28
Pages
e2402002-e2402002
ISSN
  • 0935-9648 (ISSN-L)
  • 1521-4095
OpenAlex
W4395462269
Cited by
75
References
1
Citations by year
2026: 32 · 2025: 36 · 2024: 7
FWCI
7.32
Type
journal article
Language
en
Open access
Locations
  • Advanced Materials (publishedVersion)
  • PubMed (publishedVersion)
  • Ghent University Academic Bibliography (Ghent University) (submittedVersion, other-oa)
  • Ghent University Academic Bibliography (Ghent University) (submittedVersion)
Funders
  • Universiteit Gent (BOF23/DOC/027, BOF‐GOA24021)
  • European Research Council (884963)
Topics
  • Physical Sciences › Materials Science › Materials Chemistry › Quantum Dots Synthesis And Properties
  • Physical Sciences › Engineering › Electrical and Electronic Engineering › Advanced Semiconductor Detectors and Materials
  • Physical Sciences › Physics and Astronomy › Atomic and Molecular Physics, and Optics › Semiconductor Quantum Structures and Devices
Keywords
short-wave infrared photodetection, colloidal quantum dots, PbS quantum dots, nanosecond response time, ultrathin absorber, p-n junction, Fabry-Perot cavity, external quantum efficiency, carrier extraction, light detection and ranging

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›