Textile‐Enabled Highly Reproducible Flexible Pressure Sensors for Cardiovascular Monitoring
The DOI matches its Crossref record; 8 of the 8 references it cites were found in a registry or an index.
Abstract
Flexible piezoresistive sensors (FPS) with high reproducibility and hysteresis‐free pressure response are highly desirable for various emerging biomedical applications. In this work, the potential of using regularly interlaced textile materials to achieve high‐repeatability and low‐hysteresis FPS is explored. It is found that the structural flexibility and surface regularity of knitted fabric structures can in general provide reproducible pressure response; however, response fluctuations and hysteresis are still present due to the inevitable inelastic deformation of the textiles. To address this limitation, carbon black particles and polyvinylidene fluoride are introduced in the knitted fabric as the electrical and mechanical interconnects, respectively, between the fibers. Through composition optimization, the pressure response variation is reduced to below 2% and the hysteresis loop deviation is decreased to below 10% for single sensors. The performance variation among multiple sensors is as low as 5%, much smaller than the 33% variation of the sensors made with nonwoven fabrics. Utilizing the high sensor repeatability, sensor arrays and multisite sensor network are successfully realized for monitoring superficial temporal artery pulse pressure and pulse wave velocity, which demonstrate the potential of using wearable sensing systems for multifunctional cardiovascular monitoring.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Expert consensus document on arterial stiffness: methodological issues and clinical applications
Laurent, S., Cockcroft, J., Van Bortel, L., Boutouyrie, P., Giannattasio, C., Hayoz, D., Pannier, B., Vlachopoulos, C., Wilkinson, I., Struijker-Boudier, H., et al. (2006) · European Heart Journal · doi:10.1093/eurheartj/ehl254 · Cited by 6,077
Prediction of Cardiovascular Events and All-Cause Mortality With Arterial Stiffness
Vlachopoulos, C., Aznaouridis, K., & Stefanadis, C. (2010) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2009.10.061 · Cited by 4,165
Pursuing prosthetic electronic skin
Chortos, A., Liu, J., & Bao, Z. (2016) · Nature Materials · doi:10.1038/nmat4671 · Cited by 2,396
A wearable and highly sensitive pressure sensor with ultrathin gold nanowires
Gong, S., Schwalb, W., Wang, Y., Chen, Y., Tang, Y., Si, J., Shirinzadeh, B., & Cheng, W. (2014) · Nature Communications · doi:10.1038/ncomms4132 · Cited by 2,064
Schwartz, G., Tee, B. C.-K., Mei, J., Appleton, A. L., Kim, D. H., Wang, H., & Bao, Z. (2013) · Nature Communications · doi:10.1038/ncomms2832 · Cited by 2,042
Ultrasensitive mechanical crack-based sensor inspired by the spider sensory system
Kang, D., Pikhitsa, P. V., Choi, Y. W., Lee, C., Shin, S. S., Piao, L., Park, B., Suh, K.-Y., Kim, T.-I., & Choi, M. (2014) · Nature · doi:10.1038/nature14002 · Cited by 1,626
Pan, L., Chortos, A., Yu, G., Wang, Y., Isaacson, S., Allen, R., Shi, Y., Dauskardt, R., & Bao, Z. (2014) · Nature Communications · doi:10.1038/ncomms4002 · Cited by 1,519
Lim, S., Son, D., Kim, J., Lee, Y. B., Song, J., Choi, S., Lee, D. J., Kim, J. H., Lee, M., Hyeon, T., et al. (2015) · Advanced Functional Materials · doi:10.1002/adfm.201402987 · Cited by 582
Cited by
Smart Textile‐Integrated Microelectronic Systems for Wearable Applications
Shi, J., Liu, S., Zhang, L., Yang, B., Shu, L., Yang, Y., Ren, M., Wang, Y., Chen, J., Chen, W., et al. (2020) · Advanced Materials · doi:10.1002/adma.201901958 · Cited by 822
Emerging Technologies of Flexible Pressure Sensors: Materials, Modeling, Devices, and Manufacturing
Huang, Y., Fan, X., Chen, S., & Zhao, N. (2019) · Advanced Functional Materials · doi:10.1002/adfm.201808509 · Cited by 543
Self-citationMachine-knitted washable sensor array textile for precise epidermal physiological signal monitoring
Fan, W., He, Q., Meng, K., Tan, X., Zhou, Z., Zhang, G., Yang, J., & Wang, Z. L. (2020) · Science Advances · doi:10.1126/sciadv.aay2840 · Cited by 516
Self-citationReviews of wearable healthcare systems: Materials, devices and system integration
Lou, Z., Wang, L., Jiang, K., Wei, Z., & Shen, G. (2020) · Materials Science and Engineering: R: Reports · doi:10.1016/j.mser.2019.100523 · Cited by 385
Wearable Sensing and Telehealth Technology with Potential Applications in the Coronavirus Pandemic
Ding, X., Clifton, D., Ji, N., Lovell, N. H., Bonato, P., Chen, W., Yu, X., Xue, Z., Xiang, T., Long, X., et al. (2021) · IEEE Reviews in Biomedical Engineering · doi:10.1109/rbme.2020.2992838 · Cited by 281
“[112], camera and flexible patch [114], [129], [130] as summarized in Fig.”
BackgroundSelf-citation
Metadata
- Authors
- Luo, N., Zhang, J., Ding, X., Zhou, Z., Zhang, Q., Zhang, Y., Chen, S., Hu, J., & Zhao, N.
- Venue
- Advanced Materials Technologies
- Publisher
- Wiley
- Published
- 2017-10-24
- Volume
- 3
- Issue
- 1
- ISSN
- 2365-709X (ISSN-L)
- OpenAlex
- W2766109609
- Cited by
- 96
- References
- 8
- FWCI
- 4.66
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Textile‐Enabled Highly Reproducible Flexible Pressure Sensors for Cardiovascular Monitoring. https://app.cochat.ai/papers/10.1002/admt.201700222
- The paper
- Luo, N., Zhang, J., Ding, X., Zhou, Z., Zhang, Q., Zhang, Y., Chen, S., Hu, J., & Zhao, N. (2018). Textile‐Enabled Highly Reproducible Flexible Pressure Sensors for Cardiovascular Monitoring. Advanced Materials Technologies. https://doi.org/10.1002/admt.201700222
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.