GeSn Waveguide Photodetectors with Vertical p–i–n Heterostructure for Integrated Photonics in the 2 μm Wavelength Band
Open accessAbstract
The 2 μm wavelength band (1800–2100 nm) emerges as a promising candidate for next‐generation optical communication. As a result, silicon photonic platforms acquire great interest since they offer the ultimate minimization of photonic systems for 2 μm band applications. However, the large bandgap and indirectness of the band structure of the conventional SiGe alloy prevent their utilization for efficient photodetection in the 2 μm wavelength band. To overcome this drawback, complementary metal‐oxide semiconductor (CMOS)‐compatible GeSn waveguide photodetectors (WGPDs) with a vertical p–i–n heterojunction configuration that can operate in the 2 μm wavelength band is demonstrated. The proposed photodetector incorporates 5.28% Sn into the GeSn active layer, which redshifts the photodetection range to 2090 nm. In addition, the longer light–matter interaction length and good optical confinement of the proposed GeSn WGPD enhance the optical responses significantly. As a result, the proposed GeSn WGPD achieves a responsivity up to 0.52 A W−1 and a detectivity up to 7.9 × 10 8 cm Hz ½ W−1 in the 2 μm wavelength band at room temperature. These promising results indicate that the developed GeSn WGPDs are promising candidates for integrated photonics in the 2 μm wavelength band.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The WG-QDPD outperforms monolithically grown GeSn (responsivity < 0.52 A/W and dark current > 1 mA).
“Notably, these results are on par with the best-performing bonded III-V photodetectors reported in the literature (responsivity 0.4-1.4 A/W around 2.3 μ m and dark current 10 nA-2.5 μ A), 6-9 outperforming monolithically grown GeSn (responsivity < 0.52 A/W and dark current > 1 mA). 13-16”
From A silicon photonics waveguide-coupled colloidal quantum dot photodiode sensitive beyond 1.6 µ m (2024) · cites this paper as [16]
Citations
Cites
No references could be resolved yet.
Research works printed but not linked: 51
- 10.1109/JSTQE.2006.883151 · DOI
- 10.1098/rsta.2013.0113 · DOI
- R.Soref in“Mid-Infrared Photonics " Optical Fiber Communication Conference (OFC) Optica2015 paper W4A.4. · DOI
- 10.1038/nphoton.2015.87 · DOI
- 10.1049/el:20020824 · DOI
- 10.1088/2399-6528/aaba24 · DOI
- 10.1364/OL.381960 · DOI
- 10.1364/PRJ.443144 · DOI
- 10.1364/OPTICA.4.000185 · DOI
- 10.1364/OPTICA.5.001055 · DOI
- 10.1038/s43246-021-00144-z · DOI
- 10.1063/1.4790302 · DOI
- 10.1109/JSTQE.2016.2553447 · DOI
- 10.1109/JSEN.2018.2842107 · DOI
- 10.1109/JEDS.2018.2884253 · DOI
- 10.1021/acsphotonics.9b00845 · DOI
- 10.1109/JSTQE.2021.3065204 · DOI
- 10.1364/OE.19.006400 · DOI
- 10.1063/1.4757124 · DOI
- 10.1039/D0TC03016C · DOI
- 10.1063/1.4801957 · DOI
- 10.1364/OL.383171 · DOI
- H.Tran T.Pham J.Margetis Y.Zhou W.Dou P. C.Grant J. M.Grant S.Alkabi W.Du G.Sun R. A.Soref J.Tolle B.Li M.Mortazavi S.-Q.Yu Conf. Lasers Electro-Opt. IEEE.Piscataway NJ2019 p.1.
- 10.1002/adfm.202006329 · DOI
- 10.1063/1.4903881 · DOI · Paper page
- 10.1364/OL.414580 · DOI · Paper page
- 10.1364/OL.42.001652 · DOI
- 10.1364/OL.419302 · DOI
- 10.1063/1.1993749 · DOI
- 10.1364/OE.398046 · DOI
- 10.1063/1.4905487 · DOI
- 10.1063/1.2472273 · DOI
- 10.1007/s11664-019-07254-y · DOI
- 10.1016/B978-0-08-054721-3.50037-X · DOI
- 10.1063/1.4943652 · DOI
- 10.1364/OE.24.004519 · DOI
- 10.1364/OE.409944 · DOI
- 10.1364/OE.15.003916 · DOI
- 10.1063/1.4953147 · DOI
- 10.1364/OL.43.001215 · DOI
- 10.1364/OME.8.001419 · DOI
- 10.1364/OE.23.018611 · DOI
- 10.1063/1.4840135 · DOI
- 10.1364/OE.26.017312 · DOI
- 10.1364/OE.389378 · DOI
- 10.1364/OE.420543 · DOI
- 10.1364/OE.25.015818 · DOI
- 10.1063/1.5020510 · DOI
- 10.1364/OL.434044 · DOI
- 10.1364/PRJ.413453 · DOI
- 10.1109/LED.2008.920277 · DOI
Cited by
Sorted by citations
A silicon photonics waveguide-coupled colloidal quantum dot photodiode sensitive beyond 1.6 µ m
Pang, C., Deng, Y.-H., Kheradmand, E., Hagelsieb, L. M., Guo, Y., Cheyns, D., Geiregat, P., Hens, Z., & Van Thourhout, D. (2024) · APL Photonics · doi:10.1063/5.0206386 · Cited by 9
Metadata
- Authors
- Liu, C.-H., Bansal, R., Wu, C.-W., Jheng, Y.-T., & Chang, G.-E.
- Affiliations
- National Chung Cheng University (TW)
- Graduate Institute of Opto-Mechatronics National Chung Cheng University No. 168, Section 1, University Road Minhsiung Township Chiayi County 62102 Taiwan
- Corresponding author
- Chang, Guo-En
- Venue
- Advanced Photonics Research
- Publisher
- Wiley
- Published
- 2022-03-30
- Volume
- 3
- Issue
- 7
- ISSN
- 2699-9293 (ISSN-L)
- OpenAlex
- W4220741991
- Cited by
- 22
- References
- 0
- Citations by year
- 2026: 6 · 2025: 2 · 2024: 6 · 2023: 6 · 2022: 2
- FWCI
- 1.10
- Type
- journal article
- Language
- en
- Open access
- gold
- doi.org
- Licence
- Locations
- Advanced Photonics Research (publishedVersion, cc-by)
- DOAJ (DOAJ: Directory of Open Access Journals) (submittedVersion, cc-by-sa)
- Funders
- Ministry of Science and Technology, Taiwan (MOST 109-2636-E-194-002, MOST 110-2636-E-194-002)
- Topics
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Photonic and Optical Devices
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Advanced Semiconductor Detectors and Materials
- Physical Sciences › Physics and Astronomy › Atomic and Molecular Physics, and Optics › Photorefractive and Nonlinear Optics
- Keywords
- silicon photonics, GeSn alloys, optical communication, responsivity, detectivity, light confinement
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review