CoChat

Advanced Artificial Muscle for Flexible Material‐Based Reconfigurable Soft Robots

Open access

The DOI matches its Crossref record; 28 of the 29 references it cites were found in a registry or an index.

Abstract

Flexible material‐based soft robots are widely used in various areas. In many situations, the suitable soft robots should be rapidly fabricated to complete the urgent tasks (such as rescue), so the facile fabricating methods of the multifunctional soft robots are still in urgent needs. In this work, the origami structure is employed to design vacuum‐powered silicone rubber artificial muscles, which can perform multiple motions, including contraction, bending, twisting, and radial motions. Artificial muscles can be used for rapid reconfiguration of different soft robots, just like the “building bricks”. Based on these artificial muscles, four soft robots with different functions, including an omnidirectional quadruped robot, a flexible gripper, a flexible wrist, and a pipe‐climbing robot, are reconfigured to complete different tasks. The proposed origami artificial muscles offer a facile and rapid fabricating method of flexible material‐based soft robots, and also greatly improve the utilization rate of flexible materials.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1002/advs.201901371

Cites

28 of 28 references verified0 citation errors · 0 not checkable

Statistics

Figures

Figure 1 Origami‐inspired structure of TCAM and TBAM. a) The artificial muscle inspired from square‐twist origami. H 0 is the height of artificial muscle. The solid lines indicate mountain creases and the dotted lines indicate valley creases. b) An actuated state of origami‐inspired artificial muscle. c) Top view of the TCAM. α is the pre‐twisted angle between the top and bottom facets. d) The inner structure of the TCAM. e) The inner structure of the TBAM. γ is the filling angle between the top facet and the inclined bottom of the infill. f) The tensions that curved facet is subjected to when the TCAM is evacuated. g) The clockwise TCAM is actuated by a vacuum. h) The clockwise TBAM is evacuated.
Figure 1 Origami‐inspired structure of TCAM and TBAM. a) The artificial muscle inspired from square‐twist origami. H 0 is the height of artificial muscle. The solid lines indicate mountain creases and the dotted lines indicate valley creases. b) An actuated state of origami‐inspired artificial muscle. c) Top view of the TCAM. α is the pre‐twisted angle between the top and bottom facets. d) The inner structure of the TCAM. e) The inner structure of the TBAM. γ is the filling angle between the top facet and the inclined bottom of the infill. f) The tensions that curved facet is subjected to when the TCAM is evacuated. g) The clockwise TCAM is actuated by a vacuum. h) The clockwise TBAM is evacuated.CC BY · PubMed Central
Figure 2 Performances of artificial muscles. a) The twisting angle θ and contraction ∆H of TCAM as a function of actuating pressure. b) The twisting angle θ and bending angle β of TBAM as a function of actuating pressure. Error bars indicate the SD for n = 9 measurements at each data point. c) The twisting angle θ and contraction ∆H dynamic responses of TCAM. The operation pressure (signal = 1) is −90 kPa and the releasing pressure (signal = 0) is 0 kPa. d) The twisting angle θ and bending angle β dynamic responses of TBAM. The operation pressure (signal = 1) is −90 kPa and the releasing pressure (signal = 0) is 0 kPa. e) Twisting angle θ and contraction ∆H of TCAM as a function of the times of pricking with a needle. f) Twisting angle θ and bending angle β of TBAM as a function of the times of pricking with a needle.
Figure 2 Performances of artificial muscles. a) The twisting angle θ and contraction ∆H of TCAM as a function of actuating pressure. b) The twisting angle θ and bending angle β of TBAM as a function of actuating pressure. Error bars indicate the SD for n = 9 measurements at each data point. c) The twisting angle θ and contraction ∆H dynamic responses of TCAM. The operation pressure (signal = 1) is −90 kPa and the releasing pressure (signal = 0) is 0 kPa. d) The twisting angle θ and bending angle β dynamic responses of TBAM. The operation pressure (signal = 1) is −90 kPa and the releasing pressure (signal = 0) is 0 kPa. e) Twisting angle θ and contraction ∆H of TCAM as a function of the times of pricking with a needle. f) Twisting angle θ and bending angle β of TBAM as a function of the times of pricking with a needle.CC BY · PubMed Central
Figure 3 The connection of artificial muscles and motions of combinations. a) Rigid connection. b) Soft connection. c) Contraction motion. d) Bending motion. e) Twisting motion. f) Radial motion.
Figure 3 The connection of artificial muscles and motions of combinations. a) Rigid connection. b) Soft connection. c) Contraction motion. d) Bending motion. e) Twisting motion. f) Radial motion.CC BY · PubMed Central
Figure 4 Reconfigurable soft robots. a) The modular quadruped robot. b) The flexible gripper. c) The pipe‐climbing robot. d) The flexible wrist.
Figure 4 Reconfigurable soft robots. a) The modular quadruped robot. b) The flexible gripper. c) The pipe‐climbing robot. d) The flexible wrist.CC BY · PubMed Central

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 28 references

Cited by

See all 135

Metadata

Authors
Jiao, Z., Zhang, C., Wang, W., Pan, M., Yang, H., & Zou, J.
Affiliations
  • State Key Laboratory Fluid Power and Mechatronic Systems (CN)
  • University of Bath (GB)
Corresponding author
Zou, Jun
Venue
Advanced Science
Publisher
Wiley
Published
2019-09-04
Volume
6
Issue
21
Pages
1901371-1901371
ISSN
2198-3844 (ISSN-L)
OpenAlex
W2970642377
Cited by
135
References
29
Citations by year
2026: 9 · 2025: 18 · 2024: 32 · 2023: 31 · 2022: 17 · 2021: 14 · 2020: 13 · 2019: 1
FWCI
3.97
Type
journal article
Language
en
Open access
Locations
  • Advanced Science (publishedVersion, cc-by)
  • PubMed Central (publishedVersion, cc-by)
  • PubMed (publishedVersion)
  • DOAJ (DOAJ: Directory of Open Access Journals) (submittedVersion, cc-by-sa)
Funders
National Natural Science Foundation of China (51875507, 51890885)
Topics
  • Physical Sciences › Engineering › Biomedical Engineering › Soft Robotics and Applications
  • Physical Sciences › Engineering › Mechanical Engineering › Advanced Materials and Mechanics
  • Physical Sciences › Materials Science › Electronic, Optical and Magnetic Materials › Dielectric materials and actuators
Keywords
artificial muscles, soft robots, origami-inspired design, silicone rubber, reconfigurable robots, rapid fabrication, flexible materials, quadruped robot, flexible gripper

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.