A Reconfigurable Rectified Flexible Energy Harvester via Solid‐State Single Crystal Grown PMN–PZT
The DOI matches its Crossref record; 6 of the 6 references it cites were found in a registry or an index.
Abstract
A single crystal Pb(Mg1/3Nb2/3)O3-Pb(Zr,Ti)O3 (PMN-PZT) energy harvester is demonstrated by solid-state crystal growth and an optimized delamination process. The flexible harvester generates an output voltage of 100 V and a current of 20 µA. The advanced reconfigurable rectifying circuit enhanced conversion efficiency of the PMN-PZT harvester is compared to conventional rectifier. Finally, a self-powered military boot is fabricated using the harvester as a demonstration of use in operating consumer electronics.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Nanotechnology‐Enabled Energy Harvesting for Self‐Powered Micro‐/Nanosystems
Wang, Z. L., & Wu, W. (2012) · Angewandte Chemie International Edition · doi:10.1002/anie.201201656 · Cited by 1,063
Highly‐Efficient, Flexible Piezoelectric PZT Thin Film Nanogenerator on Plastic Substrates
Park, K., Son, J. H., Hwang, G., Jeong, C. K., Ryu, J., Koo, M., Choi, I., Lee, S. H., Byun, M., Wang, Z. L., et al. (2014) · Advanced Materials · doi:10.1002/adma.201305659 · Cited by 835
Self-citationFlexible High-Output Nanogenerator Based on Lateral ZnO Nanowire Array
Zhu, G., Yang, R., Wang, S., & Wang, Z. L. (2010) · Nano Letters · doi:10.1021/nl101973h · Cited by 805
Hwang, G., Park, H., Lee, J., Oh, S., Park, K., Byun, M., Park, H., Ahn, G., Jeong, C. K., No, K., et al. (2014) · Advanced Materials · doi:10.1002/adma.201400562 · Cited by 672
Self-citationMuscle‐Driven In Vivo Nanogenerator
Li, Z., Zhu, G., Yang, R., Wang, A. C., & Wang, Z. L. (2010) · Advanced Materials · doi:10.1002/adma.200904355 · Cited by 441
Park, K., Jeong, C. K., Ryu, J., Hwang, G., & Lee, K. J. (2013) · Advanced Energy Materials · doi:10.1002/aenm.201300458 · Cited by 245
Self-citation
Cited by
High-Performance Piezoelectric Energy Harvesters and Their Applications
Yang, Z., Zhou, S., Zu, J., & Inman, D. (2018) · Joule · doi:10.1016/j.joule.2018.03.011 · Cited by 1,264
Liu, H., Zhong, J., Lee, C., Lee, S.-W., & Lin, L. (2018) · Applied Physics Reviews · doi:10.1063/1.5074184 · Cited by 905
Self-citationSafaei, M., Sodano, H. A., & Anton, S. R. (2019) · Smart Materials and Structures · doi:10.1088/1361-665x/ab36e4 · Cited by 874
“Hwang et al in 2015 [83] also developed a flexible single crystalline PMN-PZT thin film energy harvester and installed it on the heel of a combat boot.”
BackgroundSelf‐Powered Real‐Time Arterial Pulse Monitoring Using Ultrathin Epidermal Piezoelectric Sensors
Park, D. Y., Joe, D. J., Kim, D. H., Park, H., Han, J. H., Jeong, C. K., Park, H., Park, J. G., Joung, B., & Lee, K. J. (2017) · Advanced Materials · doi:10.1002/adma.201702308 · Cited by 691
Self-citationRecent progress in flexible–wearable solar cells for self-powered electronic devices
Hashemi, S. A., Ramakrishna, S., & Aberle, A. G. (2020) · Energy & Environmental Science · doi:10.1039/c9ee03046h · Cited by 527
Metadata
- Authors
- Hwang, G., Yang, J., Yang, S. H., Lee, H., Lee, M., Park, D. Y., Han, J. H., Lee, S. J., Jeong, C. K., Kim, J., Park, K., & Lee, K. J.
- Venue
- Advanced Energy Materials
- Publisher
- Wiley
- Published
- 2015-03-09
- Volume
- 5
- Issue
- 10
- ISSN
- 1614-6832 (ISSN-L)
- 1614-6840
- OpenAlex
- W2112479429
- Cited by
- 132
- References
- 6
- FWCI
- 17.98
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.