Organic liquids in a bubble column: Holdups and mass transfer coefficients
Abstract
Abstract Gas holdups and volumetric mass transfer coefficients kLa are studied in a bubble column of 0.095 m dia. with 50 different gas‐liquid systems comprising pure and mixed organic liquids and various gases. The gas holdups measured in pure organic liquids can be represented by existing correlations but the values in liquid mixtures are high. On the other hand, all mass transfer coefficients can be correlated uniformly by a new dimensionless equation, with 13.3% mean error.
Integrity signals
Registry
Cites
Statistics
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
Özturk et al. correlation has a mean error of approximately 13%, almost half compared to the predictions of Akita and Yoshida.
“The mean error is approximately 13%, being almost half compared to the predictions delivered by the correlation of Akita and Yoshida [333].”
From Modeling and Simulation of Photobioreactors with Computational Fluid Dynamics—A Comprehensive Review (2022) · cites this paper as [335]
Cites
Properties of Gases and Liquids
Elliott, J. R., Diky, V. V., Knotts, T. A., et al. (2001) · Industrial combustion series · doi:10.1201/9781420038699.axb · Cited by 1,543 · see citing works
Design parameters estimations for bubble column reactors
Shah, Y. T., Kelkar, B. G., Godbole, S. P., & Deckwer, W. ‐. (1982) · AIChE Journal · doi:10.1002/aic.690280302 · Cited by 1,202 · see citing works
Self-citationThe continuous phase heat and mass-transfer properties of dispersions
Calderbank, P. H., & Moo-Young, M. B. (1961) · Chemical Engineering Science · doi:10.1016/0009-2509(61)87005-x · Cited by 846 · see citing works
Bubble Size, Interfacial Area, and Liquid-Phase Mass Transfer Coefficient in Bubble Columns
Akita, K., & Yoshida, F. (1974) · Industrial & Engineering Chemistry Process Design and Development · doi:10.1021/i260049a016 · Cited by 740 · see citing works
Gas Holdup and Volumetric Mass Transfer Coefficient in Bubble Columns. Effects of Liquid Properties
Akita, K., & Yoshida, F. (1973) · Industrial & Engineering Chemistry Process Design and Development · doi:10.1021/i260045a015 · Cited by 684 · see citing works
Holdup and Mass Transfer in Bubble Columns
Hughmark, G. A. (1967) · Industrial & Engineering Chemistry Process Design and Development · doi:10.1021/i260022a011 · Cited by 298 · see citing works
Hikita, H., Asai, S., Tanigawa, K., Segawa, K., & Kitao, M. (1980) · The Chemical Engineering Journal · doi:10.1016/0300-9467(80)85006-4 · Cited by 287 · see citing works
Hydrodynamic Properties of the Fischer-Tropsch Slurry Process
Deckwer, W., Louisi, Y., Zaidi, A., & Ralek, M. (1980) · Industrial & Engineering Chemistry Process Design and Development · doi:10.1021/i260076a032 · Cited by 254 · see citing works
Self-citationGas Absorption by Newtonian and Non-Newtonian Liquids in a Bubble Column
Nakanoh, M., & Yoshida, F. (1980) · Industrial & Engineering Chemistry Process Design and Development · doi:10.1021/i260073a033 · Cited by 217 · see citing works
The volumetric liquid-phase mass transfer coefficient in bubble columns
Hikita, H., Asai, S., Tanigawa, K., Segawa, K., & Kitao, M. (1981) · The Chemical Engineering Journal · doi:10.1016/0300-9467(81)85006-x · Cited by 148 · see citing works
Viscous media in tower bioreactors: Hydrodynamic characteristics and mass transfer properties
Schumpe, A., & Deckwer, W. ‐. (1987) · Bioprocess and Biosystems Engineering · doi:10.1007/bf00369528 · Cited by 145 · see citing works
Self-citationBubble swarm characteristics in bubble columns
Kumar, A., Degaleesan, T. E., Laddha, G. S., & Hoelscher, H. E. (1976) · The Canadian Journal of Chemical Engineering · doi:10.1002/cjce.5450540604 · Cited by 141 · see citing works
Liquid-phase mixing in bubble columns: Effect of liquid properties
Hikita, H., & Kikukawa, H. (1974) · The Chemical Engineering Journal · doi:10.1016/0300-9467(74)85024-0 · Cited by 139 · see citing works
Hydrodynamics and mass transfer in bubble columns in operating in the churn-turbulent regime
Vermeer, D. J., & Krishna, R. (1981) · Industrial & Engineering Chemistry Process Design and Development · doi:10.1021/i200014a014 · Cited by 113 · see citing works
Effect of addition of alcohols on gas holdup and backmixing in bubble columns
Kelkar, B. G., Godbole, S. P., Honath, M. F., Shah, Y. T., Carr, N. L., & Deckwer, W. ‐. (1983) · AIChE Journal · doi:10.1002/aic.690290303 · Cited by 108 · see citing works
Self-citationDesign and Scale-Up of Bubble and Spray Columns
Mersmann, A. (1978) · Medical Entomology and Zoology · Cited by 67 · see citing works
Der relative Gasgehalt von Blasenschichten
Gestrich, W., & Rähse, W. (1975) · Chemie Ingenieur Technik · doi:10.1002/cite.330470103 · Cited by 34 · see citing works
Kölbel, H., Borchers, E., & Langemann, H. (1961) · Chemie Ingenieur Technik · doi:10.1002/cite.330331004 · Cited by 33 · see citing works
Gas holdup in a bubble column containing organic liquid mixtures
Bhaga, D., Pruden, B. B., & Weber, M. E. (1971) · The Canadian Journal of Chemical Engineering · doi:10.1002/cjce.5450490320 · Cited by 31 · see citing works
Hydrodynamics and mass transfer in a bubble column with an organic liquid
Godbole, S. P., Joseph, S., Shah, Y. T., & Carr, N. L. (1984) · The Canadian Journal of Chemical Engineering · doi:10.1002/cjce.5450620326 · Cited by 29 · see citing works
Diffusionskoeffizienten und Löslichkeiten von Sauerstoff in organischen Flüssigkeiten
Lühring, P., & Schumpe, A. (1986) · Chemie Ingenieur Technik · doi:10.1002/cite.330581214 · Cited by 24 · see citing works
Self-citationZur Ermittlung von Stoffübergangszahlen auf der Basis von Gelöstsauerstoff‐Messungen
Schumpe, A. (1985) · Chemie Ingenieur Technik · doi:10.1002/cite.330570603 · Cited by 19 · see citing works
Self-citationA correlation of diffusivities of gases in liquids
Sovová, H. (1976) · Collection of Czechoslovak Chemical Communications · doi:10.1135/cccc19763715 · Cited by 18 · see citing works
Flagged first, then by citations
Cited by
Sorted by citations
Kantarci, N., Borak, F., & Ulgen, K. O. (2005) · Process Biochemistry · doi:10.1016/j.procbio.2004.10.004 · Cited by 1,057 · see citing works
Two-Phase Bubble Columns: A Comprehensive Review
Besagni, G., Inzoli, F., & Ziegenhein, T. (2018) · ChemEngineering · doi:10.3390/chemengineering2020013 · Cited by 190 · see citing works
Modeling and Simulation of Photobioreactors with Computational Fluid Dynamics—A Comprehensive Review
Luzi, G., & McHardy, C. (2022) · Energies · doi:10.3390/en15113966 · Cited by 44 · see citing works
- Authors
- öztürk, S. S., Schumpe, A., & Deckwer, W. ‐.
- Affiliations
- Carl von Ossietzky Universität Oldenburg (DE)
- Corresponding author
- Schumpe, A.
- ORCID
- Schumpe, A.
- Venue
- AIChE Journal
- Publisher
- Wiley
- Published
- 1987-09
- Volume
- 33
- Issue
- 9
- Pages
- 1473-1480
- ISSN
- 0001-1541 (ISSN-L)
- 1547-5905
- OpenAlex
- W2129235504
- Cited by
- 143
- References
- 23
- Citations by year
- 2026: 6 · 2025: 2 · 2024: 1 · 2023: 3 · 2022: 7 · 2021: 3 · 2020: 4 · 2019: 2 · 2018: 12 · 2017: 4 · 2016: 6 · 2015: 8 · 2014: 6 · 2013: 2 · 2012: 2
- FWCI
- 3.31
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- AIChE Journal (publishedVersion)
- Funders
- Deutsche Forschungsgemeinschaft
- Topics
- Physical Sciences › Engineering › Biomedical Engineering › Fluid Dynamics and Mixing
- Physical Sciences › Environmental Science › Water Science and Technology › Minerals Flotation and Separation Techniques
- Physical Sciences › Engineering › Computational Mechanics › Fluid Dynamics and Heat Transfer
- Keywords
- bubble column, gas holdup, volumetric mass transfer coefficient, organic liquids, gas-liquid systems, liquid mixtures, dimensionless correlation, gas-liquid mass transfer
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review