The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Statistical monitoring of multivariable dynamic processes with state‐space models
Abstract
Industrial continuous processes may have a large number of process variables and are usually operated for extended periods at fixed operating points under closed‐loop control, yielding process measurements that are autocorrelated, cross‐correlated, and collinear. A statistical process monitoring (SPM) method based on multivariate statistics and system theory is introduced to monitor the variability of such processes. The statistical model that describes the in‐control variability is based on a canonical‐variate (CV) state‐space model that is an equivalent representation of a vector autoregressive moving‐average time‐series model. The CV state variables obtained from the state‐space model are linear combinations of the past process measurements that explain the variability of the future measurements the most. Because of this distinctive feature, the CV state variables are regarded as the principal dynamic directions A T 2 statistic based on the CV state variables is used for developing an SPM procedure. Simple examples based on simulated data and an experimental application based on a high‐temperature short‐time milk pasteurization process illustrate advantages of the proposed SPM method.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
A new look at the statistical model identification
Akaike, H. (1974) · IEEE Transactions on Automatic Control · doi:10.1109/tac.1974.1100705 · Cited by 51,879
Wold, S., Ruhe, A., Wold, H., & Dunn, III (1984) · SIAM Journal on Scientific and Statistical Computing · doi:10.1137/0905052 · Cited by 2,529
Cited by
Multimode process monitoring with Bayesian inference‐based finite Gaussian mixture models
Yu, J., & Qin, S. J. (2008) · AIChE Journal · doi:10.1002/aic.11515 · Cited by 494
Shang, C., Yang, F., Gao, X., Huang, X., Suykens, J. A. K., & Huang, D. (2015) · AIChE Journal · doi:10.1002/aic.14888 · Cited by 300
Monitoring, fault diagnosis, fault-tolerant control and optimization: Data driven methods
MacGregor, J., & Cinar, A. (2012) · Computers & Chemical Engineering · doi:10.1016/j.compchemeng.2012.06.017 · Cited by 277
Metadata
- Authors
- Negiz, A., & Çlinar, A.
- Venue
- AIChE Journal
- Publisher
- Wiley
- Published
- 1997-08
- Volume
- 43
- Issue
- 8
- Pages
- 2002-2020
- ISSN
- 0001-1541 (ISSN-L)
- 1547-5905
- OpenAlex
- W1988581389
- Cited by
- 259
- References
- 2
- FWCI
- 15.65
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Statistical monitoring of multivariable dynamic processes with state‐space models. https://app.cochat.ai/papers/10.1002/aic.690430810
- The paper
- Negiz, A., & Çlinar, A. (1997). Statistical monitoring of multivariable dynamic processes with state‐space models. AIChE Journal. https://doi.org/10.1002/aic.690430810
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.