CoChat

Functional imaging: I. Relative predictive value of intracranial electroencephalography

Knowlton, Robert C., Elgavish, Rotem A., Limdi, Nita, Bartolucci, Al, Ojha, Buddhiwardhan, Blount, Jeffrey, Burneo, Jorge G., Ver Hoef, Lawrence, Paige, Lebron, Faught, Edward, Kankirawatana, Pongkiat, Riley, Kristen, Kuzniecky, Ruben · 2008 · Annals of Neurology
Cited by 137

The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.

Abstract

Objective: To gain information on the predictive and prognostic value of magnetic source imaging (MSI), 2‐[18F]fluoro‐2‐deoxy‐D‐glucose positron emission tomography (18 FDG‐PET), and ictal single‐photon emission computed tomography (SPECT) as compared with intracranial electroencephalography (ICEEG) localization in epilepsy surgery. Methods: This work was part of a cohort study of epilepsy surgery candidates not sufficiently localized with noninvasive studies. Of 160 patients enrolled over 4 years, 77 completed ICEEG seizure monitoring. Sensitivity, specificity, and predictive values relative to ICEEG were computed for each modality. Results: Seizures were not captured in five patients. Of the 72 diagnostic ICEEG studies, seizure localization results were 74% localized, 10% multifocal, and 17% nonlocalized. Sixty‐one percent were localized to neocortical regions. Depending on patient subgroup pairs, sensitivity ranged from 58 to 64% (MSI), 22 to 40% (PET), and 39 to 48% (SPECT); specificity ranges were 79 to 88% (MSI), 53 to 63% (PET), and 44 to 50% (SPECT). Gains in diagnostic yield were seen only with the combination of MSI and PET or MSI and ictal SPECT. Localization concordance with ICEEG was greatest with MSI, but a significant difference was demonstrated only between MSI and PET. Moderate redundancy was seen between PET and ictal SPECT (κ = 0.452; p = 0.011). Interpretation: Conclusively positive MSI has a high predictive value for seizures localized with ICEEG. Diagnostic gain may be achieved with addition of either PET or ictal SPECT to MSI. Diagnostic values for imaging tests are lower than “true values” because of the limitations of ICEEG as a gold standard. Ann Neurol 2008

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1002/ana.21389

Cites

3 of 3 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 3 references

Cited by

See all 137

Metadata

Authors
Knowlton, R. C., Elgavish, R. A., Limdi, N., Bartolucci, A., Ojha, B., Blount, J., Burneo, J. G., Ver Hoef, L., Paige, L., Faught, E., Kankirawatana, P., Riley, K., & Kuzniecky, R.
Venue
Annals of Neurology
Publisher
Wiley
Published
2008-04-15
Volume
64
Issue
1
Pages
25-34
ISSN
  • 0364-5134 (ISSN-L)
  • 1531-8249
OpenAlex
W2035811672
Cited by
137
References
3
FWCI
7.52
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Functional imaging: I. Relative predictive value of intracranial electroencephalography. https://app.cochat.ai/papers/10.1002/ana.21389
The paper
Knowlton, R. C., Elgavish, R. A., Limdi, N., Bartolucci, A., Ojha, B., Blount, J., Burneo, J. G., Ver Hoef, L., Paige, L., Faught, E., Kankirawatana, P., Riley, K., & Kuzniecky, R. (2008). Functional imaging: I. Relative predictive value of intracranial electroencephalography. Annals of Neurology. https://doi.org/10.1002/ana.21389

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.