The DOI matches its Crossref record; 26 of the 26 references it cites were found in a registry or an index.
Label‐Free Electronic Detection of Thrombin in Blood Serum by Using an Aptamer‐Based Sensor
Abstract
Blue, gold, and DNA: A methylene blue (MB) tagged, thrombin-binding DNA aptamer immobilized on a gold surface undergoes a large conformational change upon target binding (see schematic representation; eT: electron transfer). This folding produces a large, readily measurable change in redox current and allows the electrochemical detection of thrombin in blood serum.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Tuerk, C., & Gold, L. (1990) · Science · doi:10.1126/science.2200121 · Cited by 10,405
In vitro selection of RNA molecules that bind specific ligands
Ellington, A. D., & Szostak, J. W. (1990) · Nature · doi:10.1038/346818a0 · Cited by 9,812
Laviron, E. (1979) · Journal of Electroanalytical Chemistry and Interfacial Electrochemistry · doi:10.1016/s0022-0728(79)80075-3 · Cited by 7,234
Selection of single-stranded DNA molecules that bind and inhibit human thrombin
Bock, L. C., Griffin, L. C., Latham, J. A., Vermaas, E. H., & Toole, J. J. (1992) · Nature · doi:10.1038/355564a0 · Cited by 2,469
Selection in vitro of an RNA enzyme that specifically cleaves single-stranded DNA
Robertson, D. L., & Joyce, G. F. (1990) · Nature · doi:10.1038/344467a0 · Cited by 1,331
Fan, C., Plaxco, K. W., & Heeger, A. J. (2003) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1633515100 · Cited by 1,043
Self-citationThrombin-binding DNA aptamer forms a unimolecular quadruplex structure in solution.
Macaya, R. F., Schultze, P., Smith, F. W., Roe, J. A., & Feigon, J. (1993) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.90.8.3745 · Cited by 887
Aptamer-Functionalized Au Nanoparticles for the Amplified Optical Detection of Thrombin
Pavlov, V., Xiao, Y., Shlyahovsky, B., & Willner, I. (2004) · Journal of the American Chemical Society · doi:10.1021/ja046970u · Cited by 692
Self-citationA review of molecular recognition technologies for detection of biological threat agents
Iqbal, S. S., Mayo, M. W., Bruno, J. G., Bronk, B. V., Batt, C. A., & Chambers, J. P. (2000) · Biosensors and Bioelectronics · doi:10.1016/s0956-5663(00)00108-1 · Cited by 507
The structure of alpha-thrombin inhibited by a 15-mer single-stranded DNA aptamer.
Padmanabhan, K., Padmanabhan, K. P., Ferrara, J. D., Sadler, J. E., & Tulinsky, A. (1993) · Journal of Biological Chemistry · doi:10.1016/s0021-9258(17)46749-4 · Cited by 468
Tan, W., Wang, K., & Drake, T. J. (2004) · Current Opinion in Chemical Biology · doi:10.1016/j.cbpa.2004.08.010 · Cited by 461
Options available — from start to finish — for obtaining expression data by microarray
Bowtell, D. D. L. (1999) · Nature Genetics · doi:10.1038/4455 · Cited by 439
A DNA aptamer which binds to and inhibits thrombin exhibits a new structural motif for DNA
Wang, K. Y., McCurdy, S., Shea, R. G., Swaminathan, S., & Bolton, P. H. (1993) · Biochemistry · doi:10.1021/bi00059a003 · Cited by 332
Biomaterials for Sensors, Fuel Cells, and Circuitry
Willner, I. (2002) · Science · doi:10.1126/science.298.5602.2407 · Cited by 312
Micromechanical Detection of Proteins Using Aptamer-Based Receptor Molecules
Savran, C. A., Knudsen, S. M., Ellington, A. D., & Manalis, S. R. (2004) · Analytical Chemistry · doi:10.1021/ac049859f · Cited by 310
Folding of the Thrombin Aptamer into a G-Quadruplex with Sr2+: Stability, Heat, and Hydration
Kankia, B. I., & Marky, L. A. (2001) · Journal of the American Chemical Society · doi:10.1021/ja010008o · Cited by 303
Molecular Aptamer Beacons for Real-Time Protein Recognition
Li, J. J., Fang, X., & Tan, W. (2002) · Biochemical and Biophysical Research Communications · doi:10.1006/bbrc.2002.6581 · Cited by 294
A DNA‐Based Machine That Can Cyclically Bind and Release Thrombin
Dittmer, W. U., Reuter, A., & Simmel, F. C. (2004) · Angewandte Chemie International Edition · doi:10.1002/anie.200353537 · Cited by 254
Giese, R. W. (1996) · Journal of Chromatography A · doi:10.1016/0021-9673(96)00493-1 · Cited by 242
FENTON, J. W. (1986) · Annals of the New York Academy of Sciences · doi:10.1111/j.1749-6632.1986.tb34563.x · Cited by 188
Fang, X., Sen, A., Vicens, M., & Tan, W. (2003) · ChemBioChem · doi:10.1002/cbic.200300615 · Cited by 168
Aronson, D. L., Stevan, L. J., Ball, A. P., Franza, B. R., & Finlayson, J. S. (1977) · Journal of Clinical Investigation · doi:10.1172/jci108902 · Cited by 115
Molecular Beacons: Fluorogenic Probes for Living Cell Study
Fang, X., Mi, Y., Li, J. J., Beck, T., Schuster, S. M., & Tan, W. (2002) · Cell Biochemistry and Biophysics · doi:10.1385/cbb:37:2:071 · Cited by 65
Molecular Beacon DNA Probes and Their Bioanalytical Applications
Drake, T. J., & Tan, W. (2004) · Applied Spectroscopy · doi:10.1366/0003702041959406 · Cited by 60
Selecting Nucleic Acids for Biosensor Applications
Rajendran, M., & Ellington, A. D. (2002) · Combinatorial Chemistry & High Throughput Screening · doi:10.2174/1386207023330246 · Cited by 57
[1] Fluorescence-based expression monitoring using microarrays
Winzeler, E. A., Schena, M., & Davis, R. W. (1999) · Methods in enzymology on CD-ROM/Methods in enzymology · doi:10.1016/s0076-6879(99)06003-6 · Cited by 49
Research works printed but not linked: 22
- 10.1081/AL-120034051 · doi:10.1081/al-120034051
- 10.1006/abio.2001.5169 · doi:10.1006/abio.2001.5169
- 10.1002/ange.200353537 · doi:10.1002/ange.200353537
- 10.1006/abio.2000.4595 · doi:10.1006/abio.2000.4595
- 10.1021/ja037289f · doi:10.1021/ja037289f
- 10.1016/j.bios.2004.03.037 · doi:10.1016/j.bios.2004.03.037
- 10.1039/b108940b · doi:10.1039/b108940b
- 10.1021/ac011294p · doi:10.1021/ac011294p
- 10.1016/j.bmcl.2004.10.083 · doi:10.1016/j.bmcl.2004.10.083
- 10.1093/nar/gkg764 · doi:10.1093/nar/gkg764
- 10.2174/1570164043152759 · doi:10.2174/1570164043152759
- 10.1021/ja0038171 · doi:10.1021/ja0038171
- 10.1046/j.1365-2443.2000.00331.x · doi:10.1046/j.1365-2443.2000.00331.x
- 10.1515/REVAC.2002.21.1.1 · doi:10.1515/revac.2002.21.1.1
- Bard A. J., 2001, Electrochemical Method
- 10.1021/ac010521k · doi:10.1021/ac010521k
- 10.1016/j.jelechem.2003.10.002 · doi:10.1016/j.jelechem.2003.10.002
- 10.1002/cbic.200300819 · DOI
- 10.1081/AL-120003164 · doi:10.1081/al-120003164
- 10.1016/S0960-894X(97)00351-X · doi:10.1016/s0960-894x(97)00351-x
- 10.1097/00001721-199102000-00020 · doi:10.1097/00001721-199102000-00020
- 10.1021/bi9919044 · doi:10.1021/bi9919044
Cited by
Wearable biosensors for healthcare monitoring
Kim, J., Campbell, A. S., de Ávila, B. E.-F., & Wang, J. (2019) · Nature Biotechnology · doi:10.1038/s41587-019-0045-y · Cited by 3,373
Functional Nucleic Acid Sensors
Liu, J., Cao, Z., & Lu, Y. (2009) · Chemical Reviews · doi:10.1021/cr030183i · Cited by 2,187
Song, S., Wang, L., Li, J., Fan, C., & Zhao, J. (2008) · TrAC Trends in Analytical Chemistry · doi:10.1016/j.trac.2007.12.004 · Cited by 1,434
Advances in organ-on-a-chip engineering
Zhang, B., Korolj, A., Lai, B. F. L., & Radisic, M. (2018) · Nature Reviews Materials · doi:10.1038/s41578-018-0034-7 · Cited by 1,017
Laser‐Induced Graphene: From Discovery to Translation
Ye, R., James, D. K., & Tour, J. M. (2019) · Advanced Materials · doi:10.1002/adma.201803621 · Cited by 942
Metadata
- Authors
- Xiao, Y., Lubin, A. A., Heeger, A. J., & Plaxco, K. W.
- Venue
- Angewandte Chemie International Edition
- Publisher
- Wiley
- Published
- 2005-08-22
- Volume
- 44
- Issue
- 34
- Pages
- 5456-5459
- ISSN
- 1433-7851 (ISSN-L)
- 1521-3773
- OpenAlex
- W2103205961
- Cited by
- 812
- References
- 26
- FWCI
- 12.10
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.