Exploring an Orbitrap Analyzer for the Characterization of Intact Antibodies by Native Mass Spectrometry
Open accessThe DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Abstract
Antibody profiling: native mass spectrometry analysis of intact antibodies can be achieved with improved speed, sensitivity, and mass resolution by using a modified orbitrap instrument. Complex mixtures of monoclonal antibodies can be resolved and their glycan "fingerprints" can be profiled. Noncovalent interactions are maintained, thus allowing antibody-antigen binding to be measured.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Native mass spectrometry: a bridge between interactomics and structural biology
Heck, A. J. R. (2008) · Nature Methods · doi:10.1038/nmeth.1265 · Cited by 766
Self-citationHigh-sensitivity Orbitrap mass analysis of intact macromolecular assemblies
Rose, R. J., Damoc, E., Denisov, E., Makarov, A., & Heck, A. J. R. (2012) · Nature Methods · doi:10.1038/nmeth.2208 · Cited by 392
Self-citationValeja, S. G., Kaiser, N. K., Xian, F., Hendrickson, C. L., Rouse, J. C., & Marshall, A. G. (2011) · Analytical Chemistry · doi:10.1021/ac202429c · Cited by 67
Cited by
High-Resolution Native Mass Spectrometry
Tamara, S., den Boer, M. A., & Heck, A. J. R. (2022) · Chemical Reviews · doi:10.1021/acs.chemrev.1c00212 · Cited by 511
Self-citationEvolution of Orbitrap Mass Spectrometry Instrumentation
Eliuk, S., & Makarov, A. (2015) · Annual Review of Analytical Chemistry · doi:10.1146/annurev-anchem-071114-040325 · Cited by 456
Self-citationGlycan analysis of therapeutic glycoproteins
Zhang, L., Luo, S., & Zhang, B. (2016) · mAbs · doi:10.1080/19420862.2015.1117719 · Cited by 207
Snijder, J., van de Waterbeemd, M., Damoc, E., Denisov, E., Grinfeld, D., Bennett, A., Agbandje-McKenna, M., Makarov, A., & Heck, A. J. R. (2014) · Journal of the American Chemical Society · doi:10.1021/ja502616y · Cited by 168
Self-citationHigh-fidelity mass analysis unveils heterogeneity in intact ribosomal particles
van de Waterbeemd, M., Fort, K. L., Boll, D., Reinhardt-Szyba, M., Routh, A., Makarov, A., & Heck, A. J. R. (2017) · Nature Methods · doi:10.1038/nmeth.4147 · Cited by 168
Self-citation
Metadata
- Authors
- Rosati, S., Rose, R. J., Thompson, N. J., van Duijn, E., Damoc, E., Denisov, E., Makarov, A., & Heck, A. J. R.
- Venue
- Angewandte Chemie International Edition
- Publisher
- Wiley
- Published
- 2012-11-22
- Volume
- 51
- Issue
- 52
- Pages
- 12992-12996
- ISSN
- 1433-7851 (ISSN-L)
- 1521-3773
- OpenAlex
- W2096488752
- Cited by
- 154
- References
- 3
- FWCI
- 5.72
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Exploring an Orbitrap Analyzer for the Characterization of Intact Antibodies by Native Mass Spectrometry. https://app.cochat.ai/papers/10.1002/anie.201206745
- The paper
- Rosati, S., Rose, R. J., Thompson, N. J., van Duijn, E., Damoc, E., Denisov, E., Makarov, A., & Heck, A. J. R. (2012). Exploring an Orbitrap Analyzer for the Characterization of Intact Antibodies by Native Mass Spectrometry. Angewandte Chemie International Edition. https://doi.org/10.1002/anie.201206745
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.