The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Two‐Color Probe to Monitor a Wide Range of pH Values in Cells
Abstract
High-tech pH paper: A “chameleon” pH probe composed of rhodamine (red, see scheme) and fluorescein (green) units emits at wavelengths of 580 nm and 512 nm, where the intensities show a contrary response to pH changes. Confocal microscopy of HeLa cells with this probe reveals red and green spots; the ratio of these signals can be calibrated to give the pH value of the respective organelle.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Youle, R. J., & Narendra, D. P. (2011) · Nature Reviews Molecular Cell Biology · doi:10.1038/nrm3028 · Cited by 3,273
Miksa, M., Komura, H., Wu, R., Shah, K. G., & Wang, P. (2009) · Journal of Immunological Methods · doi:10.1016/j.jim.2008.11.019 · Cited by 320
Cited by
Wan, Q., Chen, S., Shi, W., Li, L., & Ma, H. (2014) · Angewandte Chemie International Edition · doi:10.1002/anie.201405742 · Cited by 420
Hybrid Rhodamine Fluorophores in the Visible/NIR Region for Biological Imaging
Wang, L., Du, W., Hu, Z., Uvdal, K., Li, L., & Huang, W. (2019) · Angewandte Chemie International Edition · doi:10.1002/anie.201901061 · Cited by 348
Yang, L., Li, N., Pan, W., Yu, Z., & Tang, B. (2015) · Analytical Chemistry · doi:10.1021/ac503975x · Cited by 99
Metadata
- Authors
- Lee, M. H., Han, J. H., Lee, J. H., Park, N., Kumar, R., Kang, C., & Kim, J. S.
- Venue
- Angewandte Chemie International Edition
- Publisher
- Wiley
- Published
- 2013-04-22
- Volume
- 52
- Issue
- 24
- Pages
- 6206-6209
- ISSN
- 1433-7851 (ISSN-L)
- 1521-3773
- OpenAlex
- W2111988302
- Cited by
- 252
- References
- 2
- FWCI
- 12.56
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Two‐Color Probe to Monitor a Wide Range of pH Values in Cells. https://app.cochat.ai/papers/10.1002/anie.201301894
- The paper
- Lee, M. H., Han, J. H., Lee, J. H., Park, N., Kumar, R., Kang, C., & Kim, J. S. (2013). Two‐Color Probe to Monitor a Wide Range of pH Values in Cells. Angewandte Chemie International Edition. https://doi.org/10.1002/anie.201301894
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.