The DOI matches its Crossref record; 40 of the 40 references it cites were found in a registry or an index.
Ratiometric Fluorescence Imaging of Cellular Polarity: Decrease in Mitochondrial Polarity in Cancer Cells
Abstract
Mitochondrial polarity strongly influences the intracellular transportation of proteins and interactions between biomacromolecules. The first fluorescent probe capable of the ratiometric imaging of mitochondrial polarity is reported. The probe, termed BOB, has two absorption maxima (λabs=426 and 561 nm) and two emission maxima—a strong green emission (λem=467 nm) and a weak red emission (642 nm in methanol)—when excited at 405 nm. However, only the green emission is markedly sensitive to polarity changes, thus providing a ratiometric fluorescence response with a good linear relationship in both extensive and narrow ranges of solution polarity. BOB possesses high specificity to mitochondria (Rr=0.96) that is independent of the mitochondrial membrane potential. The mitochondrial polarity in cancer cells was found to be lower than that of normal cells by ratiometric fluorescence imaging with BOB. The difference in mitochondrial polarity might be used to distinguish cancer cells from normal cells.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Principles of Fluorescence Spectroscopy
Lakowicz, J. R. (1999) · Springer eBooks · doi:10.1007/978-1-4757-3061-6 · Cited by 26,947
Principles of Fluorescence Spectroscopy
(2006) · Springer eBooks · doi:10.1007/978-0-387-46312-4 · Cited by 19,339
Handbook of chemistry and physics
(1930) · Journal of the Franklin Institute · doi:10.1016/s0016-0032(30)91499-8 · Cited by 11,721
Handbook of Chemistry and Physics.
(1973) · Annals of Internal Medicine · doi:10.7326/0003-4819-79-6-934_3 · Cited by 2,559
New Strategies for Fluorescent Probe Design in Medical Diagnostic Imaging
Kobayashi, H., Ogawa, M., Alford, R., Choyke, P. L., & Urano, Y. (2010) · Chemical Reviews · doi:10.1021/cr900263j · Cited by 2,200
Mitochondria: More Than Just a Powerhouse
McBride, H. M., Neuspiel, M., & Wasiak, S. (2006) · Current Biology · doi:10.1016/j.cub.2006.06.054 · Cited by 1,985
Measurement of Mitochondrial Membrane Potential Using Fluorescent Rhodamine Derivatives
Scaduto, R. C., & Grotyohann, L. W. (1999) · Biophysical Journal · doi:10.1016/s0006-3495(99)77214-0 · Cited by 1,229
Fluorescence and Colorimetric Chemosensors for Fluoride-Ion Detection
Zhou, Y., Zhang, J. F., & Yoon, J. (2014) · Chemical Reviews · doi:10.1021/cr400352m · Cited by 1,072
Macro-/micro-environment-sensitive chemosensing and biological imaging
Yang, Z., Cao, J., He, Y., Yang, J. H., Kim, T., Peng, X., & Kim, J. S. (2014) · Chem. Soc. Rev. · doi:10.1039/c4cs00051j · Cited by 875
Self-citationA Photostable AIE Luminogen for Specific Mitochondrial Imaging and Tracking
Leung, C. W. T., Hong, Y., Chen, S., Zhao, E., Lam, J. W. Y., & Tang, B. Z. (2013) · Journal of the American Chemical Society · doi:10.1021/ja310324q · Cited by 729
Cited by
Coumarin-Based Small-Molecule Fluorescent Chemosensors
Cao, D., Liu, Z., Verwilst, P., Koo, S., Jangjili, P., Kim, J. S., & Lin, W. (2019) · Chemical Reviews · doi:10.1021/acs.chemrev.9b00145 · Cited by 1,306
Recent Development of Chemosensors Based on Cyanine Platforms
Sun, W., Guo, S., Hu, C., Fan, J., & Peng, X. (2016) · Chemical Reviews · doi:10.1021/acs.chemrev.6b00001 · Cited by 1,109
Self-citationDiscerning the Chemistry in Individual Organelles with Small‐Molecule Fluorescent Probes
Xu, W., Zeng, Z., Jiang, J., Chang, Y., & Yuan, L. (2016) · Angewandte Chemie International Edition · doi:10.1002/anie.201510721 · Cited by 808
Fluorescent probes for organelle-targeted bioactive species imaging
Gao, P., Pan, W., Li, N., & Tang, B. (2019) · Chemical Science · doi:10.1039/c9sc01652j · Cited by 599
Yin, J., Huang, L., Wu, L., Li, J., James, T. D., & Lin, W. (2021) · Chemical Society Reviews · doi:10.1039/d1cs00645b · Cited by 549
Li, H., Kim, H., Xu, F., Han, J., Yao, Q., Wang, J., Pu, K., Peng, X., & Yoon, J. (2022) · Chemical Society Reviews · doi:10.1039/d1cs00307k · Cited by 509
Self-citationZhang, J., He, B., Hu, Y., Alam, P., Zhang, H., Lam, J. W. Y., & Tang, B. Z. (2021) · Advanced Materials · doi:10.1002/adma.202008071 · Cited by 427
Design and Application of Fluorescent Probes to Detect Cellular Physical Microenvironments
Ma, J., Sun, R., Xia, K., Xia, Q., Liu, Y., & Zhang, X. (2024) · Chemical Reviews · doi:10.1021/acs.chemrev.3c00573 · Cited by 408
Activity-Based Sensing and Theranostic Probes Based on Photoinduced Electron Transfer
Sun, W., Li, M., Fan, J., & Peng, X. (2019) · Accounts of Chemical Research · doi:10.1021/acs.accounts.9b00340 · Cited by 364
Self-citationWang, K., Liu, L., Mao, D., Xu, S., Tan, C., Cao, Q., Mao, Z., & Liu, B. (2021) · Angewandte Chemie International Edition · doi:10.1002/anie.202104163 · Cited by 358
Danylchuk, D. I., Jouard, P.-H., & Klymchenko, A. S. (2021) · Journal of the American Chemical Society · doi:10.1021/jacs.0c10972 · Cited by 298
Recent progresses in fluorescent probes for detection of polarity
Xiao, H., Li, P., & Tang, B. (2021) · Coordination Chemistry Reviews · doi:10.1016/j.ccr.2020.213582 · Cited by 288
Metadata
- Authors
- Jiang, N., Fan, J., Xu, F., Peng, X., Mu, H., Wang, J., & Xiong, X.
- Venue
- Angewandte Chemie International Edition
- Publisher
- Wiley
- Published
- 2015-01-08
- Volume
- 54
- Issue
- 8
- Pages
- 2510-2514
- ISSN
- 1433-7851 (ISSN-L)
- 1521-3773
- OpenAlex
- W2149584930
- Cited by
- 258
- References
- 40
- FWCI
- 9.90
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.