The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
SERS‐Active MIL‐100(Fe) Sensory Array for Ultrasensitive and Multiplex Detection of VOCs
Abstract
The application of metal–organic frameworks (MOFs) as SERS‐active platforms in multiplex volatile organic compounds (VOCs) detection is still unexplored. Herein, we demonstrate that MIL‐100 (Fe) serves as an ideal SERS substrate for the detection of VOCs. The limit of detection (LOD) of MIL‐100(Fe) for toluene sensing can reach 2.5 ppm, and can be even further decreased to 0.48 ppb level when “hot spots” in between Au nanoparticles are employed onto MIL‐100 (Fe) substrate, resulting in an enhancement factor of 10 10. Additionally, we show that MIL‐100(Fe) substrate has a unique “sensor array” property allowing multiplex VOCs detection, with great modifiability and expandability by doping with foreign metal elements. Finally, the MIL‐100(Fe) platform is utilized to simultaneously detect the different gaseous indicators of lung cancer with a ppm detection limit, demonstrating its high potential for early diagnosis of lung cancer in vivo.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Volatile Organic Compounds of Lung Cancer and Possible Biochemical Pathways
Hakim, M., Broza, Y. Y., Barash, O., Peled, N., Phillips, M., Amann, A., & Haick, H. (2012) · Chemical Reviews · doi:10.1021/cr300174a · Cited by 953
Qiao, X., Su, B., Liu, C., Song, Q., Luo, D., Mo, G., & Wang, T. (2018) · Advanced Materials · doi:10.1002/adma.201702275 · Cited by 469
Cited by
Recent progress on MOF-based optical sensors for VOC sensing
Shen, Y., Tissot, A., & Serre, C. (2022) · Chemical Science · doi:10.1039/d2sc04314a · Cited by 256
Flexible Plasmonic Biosensors for Healthcare Monitoring: Progress and Prospects
Song, L., Chen, J., Xu, B. B., & Huang, Y. (2021) · ACS Nano · doi:10.1021/acsnano.1c07176 · Cited by 186
Jiang, L., He, C.-H., Chen, H.-Y., Xi, C.-Y., Fodjo, E. K., Zhou, Z.-R., Qian, R.-C., Li, D.-W., & Hafez, M. E. (2021) · Analytical Chemistry · doi:10.1021/acs.analchem.1c02233 · Cited by 54
Metadata
- Authors
- Fu, J., Zhong, Z., Xie, D., Guo, Y., Kong, D., Zhao, Z., Zhao, Z., & Li, M.
- Venue
- Angewandte Chemie International Edition
- Publisher
- Wiley
- Published
- 2020-08-17
- Volume
- 59
- Issue
- 46
- Pages
- 20489-20498
- ISSN
- 1433-7851 (ISSN-L)
- 1521-3773
- OpenAlex
- W3046511218
- Cited by
- 215
- References
- 2
- FWCI
- 17.90
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: SERS‐Active MIL‐100(Fe) Sensory Array for Ultrasensitive and Multiplex Detection of VOCs. https://app.cochat.ai/papers/10.1002/anie.202002720
- The paper
- Fu, J., Zhong, Z., Xie, D., Guo, Y., Kong, D., Zhao, Z., Zhao, Z., & Li, M. (2020). SERS‐Active MIL‐100(Fe) Sensory Array for Ultrasensitive and Multiplex Detection of VOCs. Angewandte Chemie International Edition. https://doi.org/10.1002/anie.202002720
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.