Student or educator? Sign up with your school email and get 6 months of Pro free.
CoChat
Cited by 169

The DOI matches its Crossref record; 6 of the 6 references it cites were found in a registry or an index.

High‐Affinity Dimeric Aptamers Enable the Rapid Electrochemical Detection of Wild‐Type and B.1.1.7 SARS‐CoV‐2 in Unprocessed Saliva

Open access
Zhang, Zijie, Pandey, Richa, Li, Jiuxing, Gu, Jimmy, White, Dawn, Stacey, Hannah D., Ang, Jann C., Steinberg, Catherine‐Jean, Capretta, Alfredo, Filipe, Carlos D. M., Mossman, Karen, Balion, Cynthia, Miller, Matthew S., Salena, Bruno J., Yamamura, Deborah, Soleymani, Leyla, Brennan, John D., Li, Yingfu · 2021 · Angewandte Chemie International Edition

Abstract

We report a simple and rapid saliva‐based SARS‐CoV‐2 antigen test that utilizes a newly developed dimeric DNA aptamer, denoted as DSA1N5, that specifically recognizes the spike proteins of the wildtype virus and its Alpha and Delta variants with dissociation constants of 120, 290 and 480 pM, respectively, and binds pseudotyped lentiviruses expressing the wildtype and alpha trimeric spike proteins with affinity constants of 2.1 pM and 2.3 pM, respectively. To develop a highly sensitive test, DSA1N5 was immobilized onto gold electrodes to produce an electrochemical impedance sensor, which was capable of detecting 1000 viral particles per mL in 1:1 diluted saliva in under 10 min without any further sample processing. Evaluation of 36 positive and 37 negative patient saliva samples produced a clinical sensitivity of 80.5 % and specificity of 100 % and the sensor could detect the wildtype virus as well as the Alpha and Delta variants in the patient samples, which is the first reported rapid test that can detect any emerging variant of SARS‐CoV‐2.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1002/anie.202110819

Cites

6 of 6 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 6 references

Cited by

See all 169

Metadata

Authors
Zhang, Z., Pandey, R., Li, J., Gu, J., White, D., Stacey, H. D., Ang, J. C., Steinberg, C., Capretta, A., Filipe, C. D. M., Mossman, K., Balion, C., Miller, M. S., Salena, B. J., Yamamura, D., Soleymani, L., Brennan, J. D., & Li, Y.
Venue
Angewandte Chemie International Edition
Publisher
Wiley
Published
2021-10-04
Volume
60
Issue
45
Pages
24266-24274
ISSN
  • 1433-7851 (ISSN-L)
  • 1521-3773
OpenAlex
W3196702900
Cited by
169
References
6
FWCI
10.07
Type
journal article
Language
en
Open access
hybrid

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: High‐Affinity Dimeric Aptamers Enable the Rapid Electrochemical Detection of Wild‐Type and B.1.1.7 SARS‐CoV‐2 in Unprocessed Saliva. https://app.cochat.ai/papers/10.1002/anie.202110819
The paper
Zhang, Z., Pandey, R., Li, J., Gu, J., White, D., Stacey, H. D., Ang, J. C., Steinberg, C., Capretta, A., Filipe, C. D. M., Mossman, K., Balion, C., Miller, M. S., Salena, B. J., Yamamura, D., Soleymani, L., Brennan, J. D., & Li, Y. (2021). High‐Affinity Dimeric Aptamers Enable the Rapid Electrochemical Detection of Wild‐Type and B.1.1.7 SARS‐CoV‐2 in Unprocessed Saliva. Angewandte Chemie International Edition. https://doi.org/10.1002/anie.202110819

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.