CoChat

Biomechanics of Dromaeosaurid Dinosaur Claws: Application of X‐Ray Microtomography, Nanoindentation, and Finite Element Analysis

Open access
Manning, Phillip L., Margetts, Lee, Johnson, Mark R., Withers, Philip J., Sellers, William I., Falkingham, Peter L., Mummery, Paul M., Barrett, Paul M., Raymont, David R. · 2009 · The Anatomical Record
Cited by 57

The DOI matches its Crossref record; 5 of the 5 references it cites were found in a registry or an index.

Abstract

Dromaeosaurid theropod dinosaurs, such as Velociraptor, possess strongly recurved, hypertrophied and hyperextensible ungual claws on the pes (digit II) and manus. The morphology of these unguals has been linked to the capture and despatching of prey. However, the mechanical properties or, more importantly, the mechanical potential of these structures have not been explored. Generation of a 3D finite element (FE) stress/strain contour map of a Velociraptor manual ungual has allowed us to evaluate quantitatively the mechanical behavior of a dromaeosaurid claw for the first time. An X‐ray microtomography scan allowed construction of an accurate 3D FE mesh. Analogue material from an extant avian theropod, the pedal digit and claw of an eagle owl (Bubo bubo), was analyzed to provide input data for the Velociraptor claw FE model (FEM). The resultant FEM confirms that dromaeosaurid claws were well‐adapted for climbing as they would have been resistant to forces acting in a single (longitudinal) plane, in this case due to gravity. However, the strength of the unguals was limited with respect to forces acting tangential to the long‐axis of the claw. The tip of the claw functioned as the puncturing and gripping element of the structure, whereas the expanded proximal portion transferred the load stress through the trabeculae and cortical bone. Enhanced climbing abilities of dromaeosaurid dinosaurs supports a scansorial phase in the evolution of flight. Anat Rec, 292:1397–1405, 2009. © 2009 Wiley‐Liss, Inc.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1002/ar.20986

Cites

5 of 5 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 5 references

Cited by

See all 57

Metadata

Authors
Manning, P. L., Margetts, L., Johnson, M. R., Withers, P. J., Sellers, W. I., Falkingham, P. L., Mummery, P. M., Barrett, P. M., & Raymont, D. R.
Venue
The Anatomical Record
Publisher
Wiley
Published
2009-08-26
Volume
292
Issue
9
Pages
1397-1405
ISSN
  • 1932-8486 (ISSN-L)
  • 1932-8494
OpenAlex
W2149170206
Cited by
57
References
5
FWCI
2.09
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Biomechanics of Dromaeosaurid Dinosaur Claws: Application of X‐Ray Microtomography, Nanoindentation, and Finite Element Analysis. https://app.cochat.ai/papers/10.1002/ar.20986
The paper
Manning, P. L., Margetts, L., Johnson, M. R., Withers, P. J., Sellers, W. I., Falkingham, P. L., Mummery, P. M., Barrett, P. M., & Raymont, D. R. (2009). Biomechanics of Dromaeosaurid Dinosaur Claws: Application of X‐Ray Microtomography, Nanoindentation, and Finite Element Analysis. The Anatomical Record. https://doi.org/10.1002/ar.20986

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.