Magnetic resonance imaging: Calculation of rates of energy absorption by a human‐torso model
The DOI matches its Crossref record; 13 of the 13 references it cites were found in a registry or an index.
Abstract
The three‐dimensional impedance method was used to estimate specific absorption rate (SAR) in a human‐torso model during exposure to the time‐varying and static magnetic fields used in magnetic resonance imaging (MRI). Analytical data for discrete tissues as well as the entire torso are presented. Generalized equations were derived that enable calculation of whole‐torso SAR over a broad range of conditions. In addition, the impedance method can generate data about internal distributions of SAR, which are needed to predict critical organs that might undergo excessive elevations of temperature. Fair to good agreement was found between impedance‐method SAR and those predicted by simple phenomenological models.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Citations
Cites
Mansfield, P., & Morris, P. G. (1982) · CERN Document Server (European Organization for Nuclear Research) · Cited by 839
Brooker, H. R. (1983) · Journal of Magnetic Resonance (1969) · doi:10.1016/0022-2364(83)90089-6 · Cited by 455
Röschmann, P. (1987) · Medical Physics · doi:10.1118/1.595995 · Cited by 232
Orcutt, N., & Gandhi, O. P. (1988) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.4590 · Cited by 181
Self-citationEstimating radiofrequency power deposition in body NMR imaging
Bottomley, P. A., Redington, R. W., Edelstein, W. A., & Schenck, J. F. (1985) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910020404 · Cited by 171
Power deposition in whole-body NMR imaging
Bottomley, P. A., & Edelstein, W. A. (1981) · Medical Physics · doi:10.1118/1.595000 · Cited by 147
Instant images of the human heart using a new, whole-body MR imaging system
Rzedzian, R., & Pykett, I. (1987) · American Journal of Roentgenology · doi:10.2214/ajr.149.2.245 · Cited by 139
Impedence Method for Calculation of Power Deposition Patterns in Magnetically Induced Hyperthermia
Gandhi, O. P., Deford, J. F., & Kanai, H. (1984) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.1984.325314 · Cited by 136
Self-citationNMR imaging techniques and applications: A review
Bottomley, P. A. (1982) · Review of Scientific Instruments · doi:10.1063/1.1137180 · Cited by 102
Deford, J. F., & Gandhi, O. P. (1985) · IEEE Transactions on Electromagnetic Compatibility · doi:10.1109/temc.1985.304281 · Cited by 80
Self-citation
Research works printed but not linked: 9
- Budinger TF, 1988, Medical Magnetic Resonance: A Primer–1988, 327
- Grandolfo M, 1987, Safety Assessment of NMR Clinical Equipment, 50
- Hutchinson JMS, 1988, The physics of NMR spectroscopy in biology and medicine
- IRPA(in press): Protection of the patient undergoing magnetic resonance examinations. Health Phys.
- Lee SY, 1985, Fourth Annual Meeting of the Society of Magnetic Resonance in Medicine, 1011
- Meyer W, 1984, Third Annual Meeting of the Society of Magnetic Resonance in Medicine, 523
- Repacholi MH, 1986, Biological Effects of Static and Extremely Low Frequency Magnetic Fields, 171
- VollmannW KuhnMH(1985): Throughput limitations in clinical MR imaging due to RF heating. In Hopf MA Bydder GM (eds): “Magnetic Resonance Imaging and Spectroscopy. Proceedings of the First Congress of the European Society of Magnetic Resonance in Medicine and Biology Geneva October 5–6 1984.” Geneva: European Society of Magnetic Resonance in Medicine and Biology pp292–298.
- Wehrli FW, 1988, Medical Magnetic Resonance: A Primer—1988, 61
Cited by
SAR and B1 field distributions in a heterogeneous human head model within a birdcage coil
Collins, C. M., Li, S., & Smith, M. B. (1998) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910400610 · Cited by 272
MEDICAL MAGNETIC RESONANCE (MR) PROCEDURES: PROTECTION OF PATIENTS
(2004) · Health Physics · doi:10.1097/00004032-200408000-00008 · Cited by 243
Computation of electromagnetic fields for high-frequency magnetic resonance imaging applications
Jin, J., Chen, J., Chew, W. C., Gan, H., Magin, R. L., & Dimbylow, P. J. (1996) · Physics in Medicine and Biology · doi:10.1088/0031-9155/41/12/011 · Cited by 119
SAR simulations for high‐field MRI: How much detail, effort, and accuracy is needed?
Wolf, S., Diehl, D., Gebhardt, M., Mallow, J., & Speck, O. (2012) · Magnetic Resonance in Medicine · doi:10.1002/mrm.24329 · Cited by 108
Liu, W., Collins, C. M., & Smith, M. B. H. (2005) · Applied Magnetic Resonance · doi:10.1007/bf03166953 · Cited by 97
Šimunić, D., Wach, P., Renhart, W., & Stollberger, R. (1996) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.477704 · Cited by 95
Numerical Evaluation of Heating of the Human Head Due to Magnetic Resonance Imaging
Nguyen, U. D., Brown, J. S., Chang, I. A., Krycia, J., & Mirotznik, M. S. (2004) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2004.827559 · Cited by 76
Inductively powered wireless pacing via a miniature pacemaker and remote stimulation control system
Abiri, P., Abiri, A., Packard, R. R. S., Ding, Y., Yousefi, A., Ma, J., Bersohn, M., Nguyen, K.-L., Markovic, D., Moloudi, S., et al. (2017) · Scientific Reports · doi:10.1038/s41598-017-06493-5 · Cited by 68
Hand, J. W., Lau, R. W. M., Lagendijk, J. J. W., Ling, J., Burl, M., & YOUNG, I. R. (1999) · Magnetic Resonance in Medicine · doi:10.1002/(sici)1522-2594(199907)42:1<183::aid-mrm24>3.0.co;2-i · Cited by 59
Murugesan, R., Afeworki, M., Cook, J. A., Devasahayam, N., Tschudin, R. G., Mitchell, J. B., Subramanian, S., & Krishna, M. C. (1998) · Review of Scientific Instruments · doi:10.1063/1.1148857 · Cited by 57
Collins, C. M., & Smith, M. B. H. (2003) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.10359 · Cited by 57
Collins, C. M. (2008) · NMR in Biomedicine · doi:10.1002/nbm.1251 · Cited by 48
Park, S. W., Wake, K., & Watanabe, S. (2013) · IEEE Transactions on Microwave Theory and Techniques · doi:10.1109/tmtt.2013.2247211 · Cited by 42
Biological Effects of Electromagnetic Fields
Macrì, M., Luzio, D., & Luzio, S. D. (2002) · International Journal of Immunopathology and Pharmacology · doi:10.1177/039463200201500204 · Cited by 41
Taylor, H. C., Burl, M., & Hand, J. W. (1997) · Physics in Medicine and Biology · doi:10.1088/0031-9155/42/7/012 · Cited by 35
Betta, G., Capriglione, D., & Pasquino, N. (2011) · Measurement · doi:10.1016/j.measurement.2011.03.001 · Cited by 19
Safety aspects and quality assessment in MRI and MRS: A challenge for health care systems in Europe
de Certaines, J. D., & Cathelineau, G. (2001) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.1089 · Cited by 19
Radiofrequency Field Calculations for High Field MRI
Collins, C. M. (2007) · Springer eBooks · doi:10.1007/978-0-387-49648-1_8 · Cited by 13
Spatial Distribution of RF Power in Critical Organs during Magnetic Resonance Imaging
Grandolfo, M., Polichetti, A., VECCHIA, P., & Gandhi, O. P. (1992) · Annals of the New York Academy of Sciences · doi:10.1111/j.1749-6632.1992.tb49607.x · Cited by 13
Self-citationAbsorption and Distribution Patterns of RF Fields
Gandhi, O. P., & Chen, J. (1992) · Annals of the New York Academy of Sciences · doi:10.1111/j.1749-6632.1992.tb49603.x · Cited by 11
Self-citationIn Vivo Intravascular Pacing Using a Wireless Microscale Stimulator
Abiri, P., Duarte‐Vogel, S., Chou, T.-C., Abiri, A., Gudapati, V., Yousefi, A., Roustaei, M., Chang, C., Cui, Q., Hsu, J. J., et al. (2021) · Annals of Biomedical Engineering · doi:10.1007/s10439-021-02729-8 · Cited by 10
Limits on Patient and Volunteer Exposure during Clinical Magnetic Resonance Diagnostic Procedures
(1992) · Annals of the New York Academy of Sciences · doi:10.1111/j.1749-6632.1992.tb49635.x · Cited by 7
Calculation of energy absorption in a human body model in a homogeneous pulsed high-frequency field
Šimunić, D. (1998) · Bioelectrochemistry and Bioenergetics · doi:10.1016/s0302-4598(98)00192-5 · Cited by 6
Wireless Pacing Using an Asynchronous Three-Tiered Inductive Power Transfer System
Abiri, P., Abiri, A., Gudapati, V., Chang, C., Roustaei, M., Bourenane, H., Anwar, U., Markovic, D. M., & Hsiai, T. K. (2020) · Annals of Biomedical Engineering · doi:10.1007/s10439-020-02450-y · Cited by 5
Load Modulation For Leadless Pacemaker Synchronization In A Dual Chamber Pacemaker System
Palaksha, D., Rizzo, G., Nocua, R., Lefeuvre, É., & Kansanen, K. (2018) · IEEE-EMBS Conference on Biomedical Engineering and Sciences · doi:10.1109/iecbes.2018.8626674 · Cited by 3
Seo, J., Jo, Y.-S., Oh, C., & Chung, J. (2022) · Sensors · doi:10.3390/s22228968 · Cited by 3
Locally Optimized B1 Field for MRI Systems
Carluccio, G. (2012) · Figshare · Cited by 1
Modeling of Static, Switched, and RF Fields in the Body for MRI
Collins, C. M. (2006) · IEEE MTT-S International Microwave Symposium digest · doi:10.1109/mwsym.2006.249453 · Cited by 1
Hu, C., Feng, J., & Xin, X. (2018) · Computers in Biology and Medicine · doi:10.1016/j.compbiomed.2018.07.015 · Cited by 1
A Comparison of Numerically Calculated SAR During MRI to the Interim Guidelines
Šimunić, D., Wach, P., & Renhart, W. (1996) · Biomedizinische Technik/Biomedical Engineering · doi:10.1515/bmte.1996.41.s1.552 · Cited by 1
Hagmann, M. J. (1992) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.184711 · Cited by 1
Towards a Wireless Pacing System for Vascular Implantation
Abiri, P. (2019) · eScholarship (California Digital Library)
New Technologies for Dosimetry: Slow Luminescence
Kiel, J. L., Bruno, J. G., & Hurt, W. D. (1995) · Springer eBooks · doi:10.1007/978-1-4899-0945-9_6
Radiofrequency Fields: Interactions, Biological Effects, and Safety Issues
Hand, J. W. (2007) · Wiley eBooks · doi:10.1002/9780470034590.emrstm0441
Analysis of possible imperilled areas in human head during magnetic resonance imaging
Šimunić, D., Wach, P., Renhart, W., Stollberger, R., & Koren, Z. (2002) · IEEE International Symposium on Electromagnetic Compatibility · doi:10.1109/isemc.1994.385615
Abstracts-part X (Continue in Part XI)
(1995) · Proceedings of the Society of Magnetic Resonance in Medicine · doi:10.1002/mrmp.22419950212
Metadata
- Authors
- Grandolfo, M., Vecchia, P., & Gandhi, O. P.
- Affiliations
- Istituto Superiore di Sanità (IT)
- Istituto Nazionale di Fisica Nucleare (IT)
- University of Utah (US)
- Corresponding author
- Grandolfo, Martino
- ORCID
- Gandhi, Om P.
- Venue
- Bioelectromagnetics
- Publisher
- Wiley
- Published
- 1990-01
- Volume
- 11
- Issue
- 2
- Pages
- 117-128
- ISSN
- 0197-8462 (ISSN-L)
- 1521-186X
- OpenAlex
- W2017746474
- Cited by
- 36
- References
- 13
- Citations by year
- 2022: 1 · 2021: 1 · 2020: 1 · 2018: 2 · 2017: 1 · 2015: 1 · 2013: 1 · 2012: 1
- FWCI
- 1.79
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- Bioelectromagnetics (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Life Sciences › Biochemistry, Genetics and Molecular Biology › Biophysics › Electromagnetic Fields and Biological Effects
- Health Sciences › Medicine › Radiology, Nuclear Medicine and Imaging › Advanced MRI Techniques and Applications
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Electromagnetic Compatibility and Measurements
- Keywords
- magnetic resonance imaging, specific absorption rate, human torso model, SAR distribution, phenomenological model
- MeSH terms
- Electromagnetic Fields, Energy Transfer, Humans, Magnetic Resonance Imaging, Models, Structural
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.