The DOI matches its Crossref record.
NMR imaging in biomedicine
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Simultaneous spatial and spectral selective excitation
Meyer, C. H., Pauly, J. M., Macovskiand, A., & Nishimura, D. G. (1990) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910150211 · Cited by 498
Magnetic resonance force microscopy
Sidles, J. A., Garbini, J. L., Bruland, K. J., Rugar, D., Züger, O., Hoen, S., & Yannoni, C. S. (1995) · Reviews of Modern Physics · doi:10.1103/revmodphys.67.249 · Cited by 466
Rapid calculation of T1 using variable flip angle gradient refocused imaging
Fram, E. K., Herfkens, R. J., Johnson, G. A., Glover, G. H., Karis, J. P., Shimakawa, A., Perkins, T. G., & Pelc, N. J. (1987) · Magnetic Resonance Imaging · doi:10.1016/0730-725x(87)90021-x · Cited by 388
Optimizing the precision in T1 relaxation estimation using limited flip angles
Wang, H. Z., Riederer, S. J., & Lee, J. N. (1987) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910050502 · Cited by 271
Magnetic resonance imaging: Calculation of rates of energy absorption by a human‐torso model
Grandolfo, M., Vecchia, P., & Gandhi, O. P. (1990) · Bioelectromagnetics · doi:10.1002/bem.2250110203 · Cited by 36
Metadata
- Authors
- Brooker, H. R.
- Venue
- Journal of Magnetic Resonance (1969)
- Publisher
- Elsevier BV
- Published
- 1983-06
- Volume
- 53
- Issue
- 1
- Pages
- 167
- ISSN
- 0022-2364 (ISSN-L)
- OpenAlex
- W2317314448
- Cited by
- 455
- References
- 0
- FWCI
- 15.23
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: NMR imaging in biomedicine. https://app.cochat.ai/papers/10.1016/0022-2364(83)90089-6
- The paper
- Brooker, H. R. (1983). NMR imaging in biomedicine. Journal of Magnetic Resonance (1969). https://doi.org/10.1016/0022-2364(83)90089-6
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.