Seismocardiogram and Ballistocardiogram Sensing
Abstract
The paper describes the latest development in seismocardiography and ballistocardiography, including sensors with or without mechanical contact with the body, for cardiac functions monitoring in common daily activity. The authors discuss the information related with the seismocardiogramn (SCG) and ballistocardiogram (BCG) and the work on SCG and BCG modeling. The latest advances reported on the devices aiming at BCG and SCG cardiovascular system evaluation are covered, highlighting their key features and novel concepts. The authors also underscore the applications of ElectroMechanical film (EMFi) sensors, MEMS accelerometers and radar sensing technology for vital signs monitoring. Discussion on the current developments and future improvements are included in the paper.
Integrity signals
Registry
Cites
Statistics
Claims the paper makes
Cites
Droitcour, A. D., Borić-Lubecke, O., Lubecke, V. M., Lin, J., & Kovacs, G. T. A. (2004) · IEEE Transactions on Microwave Theory and Techniques · doi:10.1109/tmtt.2004.823552 · Cited by 662 · see citing works
Staderini, E. M. (2002) · IEEE Aerospace and Electronic Systems Magazine · doi:10.1109/62.978359 · Cited by 498 · see citing works
Starr, I., Rawson, A. J., Schroeder, H. A., & Joseph, N. (1939) · American Journal of Physiology-Legacy Content · doi:10.1152/ajplegacy.1939.127.1.1 · Cited by 398 · see citing works
Microwave sensing of physiological movement and volume change: A review
Lin, J. C. (1992) · Bioelectromagnetics · doi:10.1002/bem.2250130610 · Cited by 301 · see citing works
ElectroMechanical Film (EMFi) — a new multipurpose electret material
Paajanen, M., Lekkala, J. O., & Kirjavainen, K. (2000) · Sensors and Actuators A Physical · doi:10.1016/s0924-4247(99)00269-1 · Cited by 289 · see citing works
A new method for long-term monitoring of the ballistocardiogram, heart rate, and respiration
Alihanka, J., Vaahtoranta, K., & Saarikivi, I. (1981) · American Journal of Physiology-Regulatory, Integrative and Comparative Physiology · doi:10.1152/ajpregu.1981.240.5.r384 · Cited by 272 · see citing works
A microwave radio for Doppler radar sensing of vital signs
Droitcour, A. D., Lubecke, V. M., Lin, J., et al. (2002) · doi:10.1109/mwsym.2001.966866 · Cited by 260 · see citing works
Xiao, Y., Lin, J., Borić-Lubecke, O., & Lubecke, M. (2006) · IEEE Transactions on Microwave Theory and Techniques · doi:10.1109/tmtt.2006.873625 · Cited by 259 · see citing works
Certain Molar Movements of the Human Body produced by the Circulation of the Blood.
Jw, G. (1877) · PubMed · Cited by 193 · see citing works
Automotive radar - status and perspectives
Wenger, J. (2005) · doi:10.1109/csics.2005.1531741 · Cited by 185 · see citing works
The influence of the respiration on the circulation in man
Lauson, H. D., Bloomfield, R. A., & Cournand, A. F. (1946) · The American Journal of Medicine · doi:10.1016/0002-9343(46)90051-4 · Cited by 152 · see citing works
Seismocardiography for Monitoring Changes in Left Ventricular Function during Ischemia
Salerno, D. M., & Zanetti, J. (1991) · Chest · doi:10.1378/chest.100.4.991 · Cited by 149 · see citing works
The graphic registration of the normal heart sounds
Rappaport, M. B., & Sprague, H. B. (1942) · American Heart Journal · doi:10.1016/s0002-8703(42)90541-6 · Cited by 123 · see citing works
Salerno, D. M., & Zanetti, J. M. (1990) · Cited by 123 · see citing works
Postolache, O. A., Girão, P. S., Mendes, J. G., Pinheiro, E. C., & Postolache, G. B. (2010) · IEEE Transactions on Instrumentation and Measurement · doi:10.1109/tim.2010.2057590 · Cited by 110 · see citing works
Self-citationDroitcour, A. D., Borić-Lubecke, O., Lubecke, V. M., & Lin, J. (2003) · Digest of technical papers/Digest of technical papers - IEEE International Solid-State Circuits Conference · doi:10.1109/isscc.2002.993075 · Cited by 105 · see citing works
A new method for measuring the ballistocardiogram using EMFi sensors in a normal chair
Koivistoinen, T., Junnila, S., Värri, A. O., et al. (2005) · doi:10.1109/iembs.2004.1403596 · Cited by 104 · see citing works
Some technics for recording the ballistocardiogram directly from the body
Dock, W., & Taubman, F. (1949) · The American Journal of Medicine · doi:10.1016/0002-9343(49)90413-1 · Cited by 98 · see citing works
Proposals for Ballistocardiographic Nomenclature and Conventions: Revised and Extended
SCARBOROUGH, W. R., Talbot, S. A., Braunstein, J. R., et al. (1956) · Circulation · doi:10.1161/01.cir.14.3.435 · Cited by 94 · see citing works
Inan, O. T., Etemadi, M., Paloma, A., Giovangrandi, L., & Kovacs, G. T. A. (2009) · Physiological Measurement · doi:10.1088/0967-3334/30/3/003 · Cited by 94 · see citing works
Kortelainen, J. M., & Virkkala, J. (2007) · Conference proceedings · doi:10.1109/iembs.2007.4353894 · Cited by 90 · see citing works
Textile Technology for the Vital Signs Monitoring in Telemedicine and Extreme Environments
Rienzo, M. D., Meriggi, P., Rizzo, F., Castiglioni, P., Lombardi, C., Ferratini, M., & Parati, G. (2010) · IEEE Transactions on Information Technology in Biomedicine · doi:10.1109/titb.2010.2048921 · Cited by 88 · see citing works
Twenty-Year Studies with the Ballistocardiograph
Starr, I., & Wood, F. C. (1961) · Circulation · doi:10.1161/01.cir.23.5.714 · Cited by 85 · see citing works
GUBNER, R. S., Rodstein, M., & Ungerleider, H. E. (1953) · Circulation · doi:10.1161/01.cir.7.2.268 · Cited by 80 · see citing works
Starr, I., Horwitz, O., Mayock, R. L., et al. (1950) · Circulation · doi:10.1161/01.cir.1.5.1073 · Cited by 80 · see citing works
Nickerson, J. L., Warren, J. V., & Brannon, E. S. (1947) · Journal of Clinical Investigation · doi:10.1172/jci101780 · Cited by 78 · see citing works
SCARBOROUGH, W. R., Mason, R. E., Davis, F. W., SINGEWALD, M. L., Baker, B. M., & Lore, S. A. (1952) · American Heart Journal · doi:10.1016/0002-8703(52)90095-1 · Cited by 77 · see citing works
THE MASS-MOVEMENTS OF THE CIRCULATION AS SHOWN BY A RECOIL CURVE
Henderson, Y. (1905) · American Journal of Physiology-Legacy Content · doi:10.1152/ajplegacy.1905.14.3.287 · Cited by 74 · see citing works
THE RELATIONSHIP BETWEEN THE CARDIAC EJECTION CURVE AND THE BALLISTOCARDIOGRAPHIC FORCES
Hamilton, W. F., Dow, P., & Remington, J. W. (1945) · American Journal of Physiology-Legacy Content · doi:10.1152/ajplegacy.1945.144.4.557 · Cited by 73 · see citing works
Medical applications of shortwave FM radar: Remote monitoring of cardiac and respiratory motion
Mostov, K. E., Liptsen, E., & Boutchko, R. (2010) · Medical Physics · doi:10.1118/1.3267038 · Cited by 72 · see citing works
THE CONSTRUCTION OF NORMAL STANDARDS FOR CARDIAC OUTPUT IN MAN
Tanner, J. M. (1949) · Journal of Clinical Investigation · doi:10.1172/jci102107 · Cited by 67 · see citing works
A non-contact vital sign monitoring system for ambulances using dual-frequency microwave radars
Suzuki, S. V., Matsui, T., Kawahara, H., et al. (2008) · Medical & Biological Engineering & Computing · doi:10.1007/s11517-008-0408-x · Cited by 62 · see citing works
Seismocardiography: waveform identification and noise analysis
Zanetti, J. M., Poliac, M. O., & Crow, R. S. (2002) · Computers in cardiology · doi:10.1109/cic.1991.169042 · Cited by 62 · see citing works
An EMFi-film sensor based ballistocardiographic chair: performance and cycle extraction method
Junnila, S., Akhbardeh, A., Värri, A. O., et al. (2006) · doi:10.1109/sips.2005.1579896 · Cited by 61 · see citing works
A Non-Contact Vital Signs Monitor
Matthews, G., Sudduth, B., & Burrow, M. (2000) · Critical Reviews in Biomedical Engineering · doi:10.1615/critrevbiomedeng.v28.i12.290 · Cited by 60 · see citing works
Cournand, A. F., Ranges, H. A., & Riley, R. L. (1942) · Journal of Clinical Investigation · doi:10.1172/jci101302 · Cited by 57 · see citing works
Noninvasive diagnosis of coronary artery disease: the cardiokymographic stress test.
Silverberg, R. A., Diamond, G. A., Vas, R., Tzivoni, D., Swan, H. J. C., & Forrester, J. S. (1980) · Circulation · doi:10.1161/01.cir.61.3.579 · Cited by 57 · see citing works
Suzuki, S. V., Matsui, T., Imuta, H., Uenoyama, M., Yura, H., Ishihara, M., & Kawakami, M. (2008) · Medical & Biological Engineering & Computing · doi:10.1007/s11517-007-0298-3 · Cited by 56 · see citing works
Physical basis of the low-frequency ballistocardiograph
Bürger, H., Noordergraaf, A., & Verhagen, A. M. W. (1953) · American Heart Journal · doi:10.1016/0002-8703(53)90241-5 · Cited by 55 · see citing works
A 5GHz Double-Sideband Radar Sensor Chip in 0.18$\mu$m CMOS for Non-Contact Vital Sign Detection
Li, C., Xiao, Y., & Lin, J. (2008) · IEEE Microwave and Wireless Components Letters · doi:10.1109/lmwc.2008.925112 · Cited by 54 · see citing works
Microwave FMCW Doppler radar implementation for in-house pervasive health care system
Postolache, O. A., Girão, P. S., Madeira, R. N., et al. (2010) · IEEE International Symposium on Medical Measurements and Applications (MeMeA) · doi:10.1109/memea.2010.5480207 · Cited by 52 · see citing works
Self-citationVital Signs Monitoring System Based on EMFi Sensors and Wavelet Analysis
Postolache, O. A., Girão, P. S., Postolache, G. B., et al. (2007) · Conference proceedings - IEEE Instrumentation/Measurement Technology Conference · doi:10.1109/imtc.2007.378999 · Cited by 49 · see citing works
Self-citationValidation of heart rate extraction through an iPhone accelerometer
Kwon, S., Lee, J., Chung, G. S., et al. (2011) · doi:10.1109/iembs.2011.6091301 · Cited by 47 · see citing works
Warren, J. V., Stead, E. A., & Brannon, E. S. (1946) · American Journal of Physiology-Legacy Content · doi:10.1152/ajplegacy.1946.145.4.458 · Cited by 45 · see citing works
Nickerson, J. L. (1949) · Journal of Clinical Investigation · doi:10.1172/jci102079 · Cited by 42 · see citing works
Unobstrusive heart rate and respiratory rate monitor embedded on a wheelchair
Postolache, O. A., Girão, P. S., Mendes, J. G., et al. (2009) · IEEE International Symposium on Medical Measurements and Applications (MeMeA) · doi:10.1109/memea.2009.5167960 · Cited by 41 · see citing works
Self-citationInan, O. T., Etemadi, M., Widrow, B. C., et al. (2009) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2009.2018831 · Cited by 38 · see citing works
摩希子, 佐., Hong, J.-H., 富章, 山., et al. (2007) · Conference proceedings · doi:10.1109/iembs.2007.4352355 · Cited by 37 · see citing works
Three dimensional ballistocardiography: Methodology and results from microgravity and dry immersion
Migeotte, P., Tank, J., Pattyn, N., Funtova, I. I., Baevsky, R. M., Neyt, X., & Prisk, G. K. (2011) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/iembs.2011.6091060 · Cited by 37 · see citing works
Phonocardiographic studies of early rheumatic mitral disease
Taquini, A. C., Massell, B. F., & Walsh, B. J. (1940) · American Heart Journal · doi:10.1016/s0002-8703(40)91115-2 · Cited by 35 · see citing works
Wide Frequency Range Force Ballistocardiogram
Reeves, T. J., Hefner, L. L., Jones, W. B., et al. (1957) · Circulation · doi:10.1161/01.cir.16.1.43 · Cited by 35 · see citing works
Thompson, W. B., Rappaport, M. B., & Sprague, H. B. (1953) · Circulation · doi:10.1161/01.cir.7.3.321 · Cited by 33 · see citing works
Cardio-respiratory and daily activity monitor based on FMCW Doppler radar embedded in a wheelchair
Postolache, O. A., Girão, P. S., Postolache, G. B., et al. (2011) · doi:10.1109/iembs.2011.6090542 · Cited by 33 · see citing works
Self-citationThe Heart-Sounds in Normal and Pathological Conditions
Orias, O., & Braun-Menendez, E. (1940) · Southern Medical Journal · doi:10.1097/00007611-194006000-00033 · Cited by 33 · see citing works
Acceleration Ballistocardiography
ELLIOTT, R. V., PACKARD, R. G., & Kyrazis, D. T. (1954) · Circulation · doi:10.1161/01.cir.9.2.281 · Cited by 32 · see citing works
Static‐charge‐sensitive bed ballistocardiography in cardiovascular monitoring
Lindqvist, A. E., Pihlajamäki, K. K., Jalonen, J. R., LAAKSONEN, V. O., & Alihanka, J. (1996) · Clinical Physiology · doi:10.1111/j.1475-097x.1996.tb00553.x · Cited by 32 · see citing works
BSeg++: A modified Blind Segmentation Method for Ballistocardiogram Cycle Extraction
Akhbardeh, A., Kamińska, B., & Tavakolian, K. (2007) · Conference proceedings · doi:10.1109/iembs.2007.4352686 · Cited by 32 · see citing works
Accuracy of cardiokymography during exercise testing: Results of a multicenter study
Weiner, D. A. (1985) · Journal of the American College of Cardiology · doi:10.1016/s0735-1097(85)80105-4 · Cited by 30 · see citing works
An Empiric Approach to the Interpretation of the Low Frequency Critically Damped Ballistocardiogram
JONES, R. J., & Goulder, N. E. (1950) · Circulation · doi:10.1161/01.cir.2.5.756 · Cited by 30 · see citing works
Ballistocardiograms in Coarctation of the Aorta
Brown, H. R., Hoffman, M. J., & DeLalla, V. (1949) · New England Journal of Medicine · doi:10.1056/nejm194905052401803 · Cited by 27 · see citing works
Comparative analysis of seismocardiogram waves with the ultra-low frequency ballistocardiogram
Ngai, B., Tavakolian, K., Akhbardeh, A., Blaber, A. P., Kamińska, B., & Noordergraaf, A. (2009) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/iembs.2009.5333649 · Cited by 25 · see citing works
The apexcardiogram in ischemic heart disease.
Wayne, H. H. (1972) · PubMed · Cited by 23 · see citing works
Ballistocardiography: a clinical review.
Pollock, P. (1957) · PubMed · Cited by 23 · see citing works
Wheelchair type biomedical system with event-recorder function
Han, D.-K., Kim, J., Cha, E., et al. (2008) · doi:10.1109/iembs.2008.4649436 · Cited by 18 · see citing works
Analysis of H Wave of Ballistocardiogram
de Lalla, V., Epstein, M. A., & Brown, H. R. (1950) · Circulation · doi:10.1161/01.cir.2.5.765 · Cited by 13 · see citing works
Online heart rate estimation in unstable ballistocardiographic records
Pinheiro, E., Postolache, O. A., & Girão, P. S. (2010) · Proceedings of the Annual International Conference of the IEEE Engineering in Medicine and Biology Society · doi:10.1109/iembs.2010.5627539 · Cited by 13 · see citing works
Self-citationPinheiro, E. C., Postolache, O. A., & Girão, P. S. (2010) · Proceedings of the Annual International Conference of the IEEE Engineering in Medicine and Biology Society · doi:10.1109/iembs.2010.5626646 · Cited by 13 · see citing works
Self-citationSCARBOROUGH, W. R., & Baker, B. M. (1957) · Circulation · doi:10.1161/01.cir.16.6.971 · Cited by 12 · see citing works
Mathematical Model of Seismocardiogram
Holcik, J., & Moudr, J. (2007) · Springer eBooks · doi:10.1007/978-3-540-36841-0_864 · Cited by 10 · see citing works
Wick, C. A., Su, J.-J., Brand, O., McClellan, J. H., Bhatti, P. T., & Tridandapani, S. (2011) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/iembs.2011.6091740 · Cited by 10 · see citing works
A novel FM-UWB system for vital sign monitoring and its comparison with IR-UWB
Gupta, B., Cianca, E., Ruggieri, M., et al. (2009) · International Symposium on Applied Sciences in Biomedical and Communication Technologies · doi:10.1109/isabel.2009.5373708 · Cited by 10 · see citing works
A high precision 24 GHz FMCW-radar based on a fractional-N ramp-PLL
Musch, T. (2003) · doi:10.1109/cpem.2002.1034791 · Cited by 8 · see citing works
Chest Motion Sensing with Modified Silicon Base Station Chips
Droitcour, A. D., Borić-Lubecke, O., Lubecke, V. M., et al. (2004) · IEICE Transactions on Electronics · Cited by 6 · see citing works
Yu, X., Gong, D., Shuen, X., et al. (2004) · doi:10.1109/rissp.2003.1285567 · Cited by 6 · see citing works
Quantitative Ballistocardiography (Q-BCG) for Measurement of Cardiovascular Dynamics
Trefný, Z., Svačinka, J., Kittnar, O., et al. (2011) · Physiological Research · doi:10.33549/physiolres.931993 · Cited by 5 · see citing works
A Proposed Nomenclature and Convention for Recording the Ballistocardiogram
Braunstein, J. R. (1953) · Circulation · doi:10.1161/01.cir.7.6.927 · Cited by 4 · see citing works
Physiology in health and disease
Harrison, T. R. (1940) · American Heart Journal · doi:10.1016/s0002-8703(40)90222-8 · Cited by 4 · see citing works
Postolache, O. A., Girão, P. S., Postolache, G. B., et al. (2010) · Control and Intelligent Systems · doi:10.2316/j.2010.216.680-0098 · Cited by 4 · see citing works
Self-citation
Flagged first, then by citations
Cited by
Sorted by citations
Liu, Y., Norton, J. J. S., Qazi, R., Zou, Z., Ammann, K. R., Liu, H., Yan, L., Tran, P. L., Jang, K.-I., Lee, J. W., et al. (2016) · Science Advances · doi:10.1126/sciadv.1601185 · Cited by 397 · see citing works
Ha, T., Tran, J., Liu, S., Jang, H., Jeong, H., Mitbander, R., Huh, H., Qiu, Y., Duong, J., Wang, R. L., et al. (2019) · Advanced Science · doi:10.1002/advs.201900290 · Cited by 220 · see citing works
- Authors
- Postolache, O., Girão, P., & Postolache, G.
- Affiliations
- Universidade Politécnica de Setúbal (PT)
- Instituto de Telecomunicações (PT)
- Atlântica Instituto Universitário (PT)
- Venue
- Advanced Instrument Engineering
- Publisher
- IGI Global
- Published
- 2013
- Pages
- 223-246
- OpenAlex
- W4252626392
- Cited by
- 5
- References
- 78
- Citations by year
- 2019: 2 · 2017: 1 · 2016: 2
- FWCI
- 1.99
- Type
- book chapter
- Language
- en
- Open access
- closed
- Locations
- IGI Global eBooks (publishedVersion)
- Topics
- Physical Sciences › Engineering › Biomedical Engineering › Non-Invasive Vital Sign Monitoring
- Physical Sciences › Engineering › Biomedical Engineering › Advanced Sensor and Energy Harvesting Materials
- Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › ECG Monitoring and Analysis
- Keywords
- seismocardiography, ballistocardiography, seismocardiogram, cardiac monitoring, non-contact sensors, MEMS accelerometer, radar sensing, vital signs monitoring, sensor modeling
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›