Real‐time in situ monitoring of freely suspended and immobilized cell cultures based on mid‐infrared spectroscopic measurements

Open access
Rhiel, Martin, Ducommun, Paul, Bolzonella, Ivan, Marison, Ian, von Stockar, Urs · 2002 · Biotechnology and Bioengineering
Cited by 83

The DOI matches its Crossref record.

Abstract

Glucose and lactate profiles in Chinese hamster ovary cell cultures were accurately monitored in real time and in situ during three bioreactor batch cultures lasting 11,15, and 15 days performed within a 60‐day period. Monitoring was accomplished using in situ‐collected mid‐infrared spectra analyzed with a priori one‐time established partial least‐squares regression models. The robustness of the technique was demonstrated by application of these models without modification after 2.3 years. Neither recalibration nor instrument maintenance was required during the 2.3‐year period, except for the daily filling of liquid nitrogen for detector cooling during operation. The lactate calibration model yielded accurate absolute concentration estimations during each of the batch cultures with standard errors of estimate from 1 to 3 m M. The a priori‐established glucose calibration model yielded concentration estimations with an off‐set, which was constant throughout a culture. Adjustment of the off‐set before inoculation resulted in accurate concentration estimations with Standard errors of estimate of approximately 1 m M for each of the bioreactor cultures. Sensitivity in detecting differences of 0.5 m M and selectivity against variation of one metabolite while the other was kept constant was demonstrated during standard additions of either glucose or lactate. The sensor system proved to be reliable, simple, accurate, sterile, and capable of long‐term automatic operation and is considered to be mature enough to be routinely applied for in situ (on‐line) cell culture monitoring. © 2002 John Wiley & Sons, Inc. Biotechnol Bioeng 77: 174–185, 2002.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1002/bit.10134

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 83

Metadata

Authors
Rhiel, M., Ducommun, P., Bolzonella, I., Marison, I., & von Stockar, U.
Venue
Biotechnology and Bioengineering
Publisher
Wiley
Published
2001-12-05
Volume
77
Issue
2
Pages
174-185
ISSN
  • 0006-3592 (ISSN-L)
  • 1097-0290
OpenAlex
W2100578096
Cited by
83
References
0
FWCI
1.88
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Real‐time in situ monitoring of freely suspended and immobilized cell cultures based on mid‐infrared spectroscopic measurements. https://app.cochat.ai/papers/10.1002/bit.10134
The paper
Rhiel, M., Ducommun, P., Bolzonella, I., Marison, I., & von Stockar, U. (2002). Real‐time in situ monitoring of freely suspended and immobilized cell cultures based on mid‐infrared spectroscopic measurements. Biotechnology and Bioengineering. https://doi.org/10.1002/bit.10134

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.