Monitoring of complex industrial bioprocesses for metabolite concentrations using modern spectroscopies and machine learning: Application to gibberellic acid production
The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.
Abstract
Two rapid vibrational spectroscopic approaches (diffuse reflectance–absorbance Fourier transform infrared [FT‐IR] and dispersive Raman spectroscopy), and one mass spectrometric method based on in vacuo Curie‐point pyrolysis (PyMS), were investigated in this study. A diverse range of unprocessed, industrial fed‐batch fermentation broths containing the fungus Gibberella fujikuroi producing the natural product gibberellic acid, were analyzed directly without a priori chromatographic separation. Partial least squares regression (PLSR) and artificial neural networks (ANNs) were applied to all of the information‐rich spectra obtained by each of the methods to obtain quantitative information on the gibberellic acid titer. These estimates were of good precision, and the typical root‐mean‐square error for predictions of concentrations in an independent test set was <10% over a very wide titer range from 0 to 4925 ppm. However, although PLSR and ANNs are very powerful techniques they are often described as “black box” methods because the information they use to construct the calibration model is largely inaccessible. Therefore, a variety of novel evolutionary computation‐based methods, including genetic algorithms and genetic programming, were used to produce models that allowed the determination of those input variables that contributed most to the models formed, and to observe that these models were predominantly based on the concentration of gibberellic acid itself. This is the first time that these three modern analytical spectroscopies, in combination with advanced chemometric data analysis, have been compared for their ability to analyze a real commercial bioprocess. The results demonstrate unequivocally that all methods provide very rapid and accurate estimates of the progress of industrial fermentations, and indicate that, of the three methods studied, Raman spectroscopy is the ideal bioprocess monitoring method because it can be adapted for on‐line analysis. © 2002 Wiley Periodicals, Inc. Biotechnol Bioeng 78: 527–538, 2002.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
An Introduction to Genetic Algorithms
Mitchell, M. (1996) · doi:10.7551/mitpress/3927.001.0001 · Cited by 11,340
Fourier Transform Infrared Spectrometry
Griffiths, P. R., & de Haseth, J. A. (2007) · doi:10.1002/047010631x · Cited by 3,052
Shaw, A. D., Kaderbhai, N., Jones, A., Woodward, A. M., Goodacre, R., Rowland, J. J., & Kell, D. B. (1999) · Applied Spectroscopy · doi:10.1366/0003702991945777 · Cited by 84 · cited 2×
“Moreover, because HPLC takes 30 min plus additional extraction and sample preparation time, the speed of the measurements from PyMS (2 min), FT-IR (10 s), and Raman spectroscopy (1 min) makes them particularly attractive to industry (Shaw et al., 1999b; Validyanathan et al., 1999).”
BackgroundMethodSelf-citationChemometrics, why, what and where to next?
Wold, S. (1991) · Journal of Pharmaceutical and Biomedical Analysis · doi:10.1016/0731-7085(91)80183-a · Cited by 56
Cited by
Plant metabolomics: large-scale phytochemistry in the functional genomics era
Sumner, L. W., Mendes, P., & Dixon, R. A. (2003) · Phytochemistry · doi:10.1016/s0031-9422(02)00708-2 · Cited by 1,093
Measuring the metabolome: current analytical technologies
Dunn, W. B., Bailey, N. J. C., & Johnson, H. E. (2005) · The Analyst · doi:10.1039/b418288j · Cited by 924
Ellis, D. I., & Goodacre, R. (2006) · The Analyst · doi:10.1039/b602376m · Cited by 614
Self-citationAbu‐Absi, N. R., Kenty, B. M., Cuellar, M. E., Borys, M. C., Sakhamuri, S., Strachan, D. J., Hausladen, M. C., & Li, Z. J. (2011) · Biotechnology and Bioengineering · doi:10.1002/bit.23023 · Cited by 322
“Both near infrared (NIR) and mid-infrared (MIR) spectroscopy have been extensively applied for monitoring a variety of bioprocesses (Card et al., 2008; McGovern et al., 2002; Sivakesava et al., 2001a,b).”
BackgroundWhelan, J., Craven, S., & Glennon, B. (2012) · Biotechnology Progress · doi:10.1002/btpr.1590 · Cited by 159
Optical sensor systems for bioprocess monitoring
Ulber, R., Frerichs, J.-G., & Beutel, S. (2003) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-003-1930-1 · Cited by 151
Berry, B., Moretto, J., Matthews, T., Smelko, J., & Wiltberger, K. (2015) · Biotechnology Progress · doi:10.1002/btpr.2035 · Cited by 142
Bhatia, H., Mehdizadeh, H., Drapeau, D., & Yoon, S. (2018) · Engineering in Life Sciences · doi:10.1002/elsc.201700084 · Cited by 87
“spectral data generated by Raman spectroscopy, chemometrics methods of data analysis are ideal, as they can be applied to extract useful information out of vast amounts of data [6, 19, 20].”
Background
Metadata
- Authors
- McGovern, A. C., Broadhurst, D., Taylor, J., Kaderbhai, N., Winson, M. K., Small, D. A., Rowland, J. J., Kell, D. B., & Goodacre, R.
- Venue
- Biotechnology and Bioengineering
- Publisher
- Wiley
- Published
- 2002-04-17
- Volume
- 78
- Issue
- 5
- Pages
- 527-538
- ISSN
- 0006-3592 (ISSN-L)
- 1097-0290
- OpenAlex
- W2172252689
- Cited by
- 83
- References
- 4
- FWCI
- 10.53
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.