The DOI matches its Crossref record.
Preparation, stability, and in vitro performance of vesicles made with diblock copolymers
Abstract
Vesicles made completely from diblock copolymers—polymersomes—can be stably prepared by a wide range of techniques common to liposomes. Processes such as film rehydration, sonication, and extrusion can generate many‐micron giants as well as monodisperse, ∼100 nm vesicles of PEO‐PEE (polyethyleneoxide‐polyethylethylene) or PEO‐PBD (polyethyleneoxide‐polybutadiene). These thick‐walled vesicles of polymer can encapsulate macromolecules just as liposomes can but, unlike many pure liposome systems, these polymersomes exhibit no in‐surface thermal transitions and a subpopulation even survive autoclaving. Suspension in blood plasma has no immediate ill‐effect on vesicle stability, and neither adhesion nor stimulation of phagocytes are apparent when giant polymersomes are held in direct, protracted contact. Proliferating cells, in addition, are unaffected when cultured for an extended time with an excess of polymersomes. The effects are consistent with the steric stabilization that PEG‐lipid can impart to liposomes, but the present single‐component polymersomes are far more stable mechanically and are not limited by PEG‐driven micellization. The results potentiate a broad new class of technologically useful, polymer‐based vesicles. © 2001 John Wiley & Sons, Inc. Biotechnol Bioeng 73: 135–145, 2001.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Stimuli-Responsive Polymersomes for Programmed Drug Delivery
Meng, F., Zhong, Z., & Feijen, J. (2009) · Biomacromolecules · doi:10.1021/bm801127d · Cited by 1,122
Oxidation-responsive polymeric vesicles
Napoli, A., Valentini, M., Tirelli, N., Müller, M., & Hubbell, J. A. (2004) · Nature Materials · doi:10.1038/nmat1081 · Cited by 889
Discher, D. E., & Ahmed, F. (2006) · Annual Review of Biomedical Engineering · doi:10.1146/annurev.bioeng.8.061505.095838 · Cited by 844
Self-citationSelf-porating polymersomes of peg–pla and peg–pcl: Hydrolysis-triggered controlled release vesicles
Ahmed, F., & Discher, D. E. (2004) · Journal of Controlled Release · doi:10.1016/j.jconrel.2003.12.021 · Cited by 667
Self-citationUltrasonic drug delivery – a general review
Pitt, W. G., Husseini, G. A., & Staples, B. J. (2004) · Expert Opinion on Drug Delivery · doi:10.1517/17425247.1.1.37 · Cited by 621
Advances and challenges in smart and functional polymer vesicles
Du, J., & O'Reilly, R. K. (2009) · Soft Matter · doi:10.1039/b905635a · Cited by 572
Polymer vesicles in vivo: correlations with PEG molecular weight
Photos, P. J., Bacakova, L., Discher, B., Bates, F. S., & Discher, D. E. (2003) · Journal of Controlled Release · doi:10.1016/s0168-3659(03)00201-3 · Cited by 527
Self-citationBlock copolymer vesicles—using concepts from polymer chemistry to mimic biomembranes
Kita-Tokarczyk, K., Grumelard, J., Haefele, T., & Meier, W. (2005) · Polymer · doi:10.1016/j.polymer.2005.02.083 · Cited by 517
Stimuli-Responsive Polymers and Their Applications in Nanomedicine
Cabane, E., Zhang, X., Langowska, K., Palivan, C. G., & Meier, W. (2012) · Biointerphases · doi:10.1007/s13758-011-0009-3 · Cited by 468
Stimuli‐Responsive Polymersomes as Nanocarriers for Drug and Gene Delivery
Onaca, O., Enea, R., Hughes, D. W., & Meier, W. (2009) · Macromolecular Bioscience · doi:10.1002/mabi.200800248 · Cited by 465
Polymersomes: nature inspired nanometer sized compartments
LoPresti, C., Lomas, H., Massignani, M., Smart, T., & Battaglia, G. (2009) · Journal of Materials Chemistry · doi:10.1039/b818869f · Cited by 416
van Dongen, S. F. M., de Hoog, H.-P. M., Peters, R. J. R. W., Nallani, M., Nolte, R. J. M., & van Hest, J. C. M. (2009) · Chemical Reviews · doi:10.1021/cr900072y · Cited by 386
Development of an artificial cell, from self-organization to computation and self-reproduction
Noireaux, V., Maeda, Y. T., & Libchaber, A. (2011) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1017075108 · Cited by 340
Thermo-responsive Diblock Copolymer Worm Gels in Non-polar Solvents
Fielding, L. A., Lane, J. A., Derry, M. J., Mykhaylyk, O. O., & Armes, S. P. (2014) · Journal of the American Chemical Society · doi:10.1021/ja501756h · Cited by 309
Functionalized carbon nanotubes for anticancer drug delivery
Lay, C. L., Liu, J., & Liu, Y. (2011) · Expert Review of Medical Devices · doi:10.1586/erd.11.34 · Cited by 71
In situ formation of magnetopolymersomes via electroporation for MRI
Bain, J., Ruiz-Pérez, L., Kennerley, A. J., Muench, S. P., Thompson, R., Battaglia, G., & Staniland, S. S. (2015) · Scientific Reports · doi:10.1038/srep14311 · Cited by 24
Metadata
- Authors
- Lee, J. C., Bermudez, H., Discher, B. M., Sheehan, M. A., Won, Y., Bates, F. S., & Discher, D. E.
- Venue
- Biotechnology and Bioengineering
- Publisher
- Wiley
- Published
- 2001-02-26
- Volume
- 73
- Issue
- 2
- Pages
- 135-145
- ISSN
- 0006-3592 (ISSN-L)
- 1097-0290
- OpenAlex
- W2109239812
- Cited by
- 392
- References
- 0
- FWCI
- 7.48
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.