On‐line biomass monitoring of CHO perfusion culture with scanning dielectric spectroscopy
Open accessThe DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Abstract
In this work, dielectric spectroscopy was used to monitor two CHO perfusion culture experiments (B14 and B16). The capacitance of the cell suspension was recorded every 20 minutes over an excitation frequency range of 0.2 MHz to 10.0 MHz. A phase plot of the capacitance at a low excitation frequency vs. the value at a higher frequency proved to be an accurate indicator of the major transition points of the culture, i.e., maximum cell viability, end of lactate consumption, point of zero viability. For both experiments, the capacitance signal correlated very well (R2 >0.98) with viable cell number up to concentrations of 1 × 10 7 cells/mL. Visual observation of the capacitance spectra indicated that changes in the capacitance relative to frequency were related to the cellular morphology. A multivariate model was developed using off‐line data that could predict the median cell diameter within a single experiment (B14) with an error of 0.34 μm (2%). Upon extension to a subsequent experiment (B16), the predicted error was 1.18 μm (9%). © 2003 Wiley Periodicals, Inc. Biotechnol Bioeng 84: 597–610, 2003.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Smoothing and Differentiation of Data by Simplified Least Squares Procedures.
Savitzky, A., & Golay, M. J. E. (1964) · Analytical Chemistry · doi:10.1021/ac60214a047 · Cited by 21,904
Optical sensor systems for bioprocess monitoring
Marose, S. (1999) · Trends in biotechnology · doi:10.1016/s0167-7799(98)01247-5 · Cited by 102
Peñaloza, W., Davey, C. L., Hedger, J. N., & Kell, D. B. (1992) · Journal of the Science of Food and Agriculture · doi:10.1002/jsfa.2740590214 · Cited by 29 · cited 1×
“…Biselli, 1998; Siano, 1997; Zeiser et al., 1999), plant cell culture (Markx et al., 1991) and microbial fermentation (Davey et al., 1996; Gheorghiu and Asami, 1998; Krairak et al., 1999;Markx and Kell, 1995; Nicholson et al., 1996; November and van Impe, 2000; Penaloza et al., 1992; Siano, 1997).”
Background
Cited by
Modern Sensor Tools and Techniques for Monitoring, Controlling, and Improving Cell Culture Processes
Reyes, S. J., Durocher, Y., Pham, P. L., & Henry, O. (2022) · Processes · doi:10.3390/pr10020189 · Cited by 130
Advances in process monitoring tools for cell culture bioprocesses
Zhao, L., Fu, H., Zhou, W., & Hu, W. (2015) · Engineering in Life Sciences · doi:10.1002/elsc.201500006 · Cited by 81
Konakovsky, V., Clemens, C., Müller, M., Bechmann, J., Berger, M., Schlatter, S., & Herwig, C. (2016) · Bioengineering · doi:10.3390/bioengineering3010005 · Cited by 44
“This target rate was set up by estimating cell count via a capacitance probe, which can be used either for process monitoring [71–74] or control purposes [47,75].”
MethodUniversal capacitance model for real-time biomass in cell culture
Konakovsky, V., Yagtu, A., Clemens, C., Müller, M., Berger, M., Schlatter, S., & Herwig, C. (2015) · Sensors · doi:10.3390/s150922128 · Cited by 41
“Some researchers have observed that size alone cannot explain the difference in slope [8,12] of biological objects, or only after extensive offline de-correlation [35], which is not in the spirit of automatic process control.”
BackgroundMethodInfluentialRafferty, C., O’Mahony, J., Rea, R., Burgoyne, B., Balss, K. M., Lyngberg, O., O’Mahony-Hartnett, C., Hill, D., & Schaefer, E. (2020) · Bioprocess and Biosystems Engineering · doi:10.1007/s00449-020-02336-2 · Cited by 21
Metadata
- Authors
- Cannizzaro, C., Gügerli, R., Marison, I., & von Stockar, U.
- Venue
- Biotechnology and Bioengineering
- Publisher
- Wiley
- Published
- 2003-09-24
- Volume
- 84
- Issue
- 5
- Pages
- 597-610
- ISSN
- 0006-3592 (ISSN-L)
- 1097-0290
- OpenAlex
- W2132152849
- Cited by
- 130
- References
- 3
- FWCI
- 0.97
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.