The DOI matches its Crossref record; 20 of the 20 references it cites were found in a registry or an index.
Continuous perfusion microfluidic cell culture array for high‐throughput cell‐based assays
Open accessAbstract
We present for the first time a microfluidic cell culture array for long‐term cellular monitoring. The 10 × 10 array could potentially assay 100 different cell‐based experiments in parallel. The device was designed to integrate the processes used in typical cell culture experiments on a single self‐contained microfluidic system. Major functions include repeated cell growth/passage cycles, reagent introduction, and real‐time optical analysis. The single unit of the array consists of a circular microfluidic chamber, multiple narrow perfusion channels surrounding the main chamber, and four ports for fluidic access. Human carcinoma (HeLa) cells were cultured inside the device with continuous perfusion of medium at 37°C. The observed doubling time was 1.4 ± 0.1 days with a peak cell density of ∼2.5*10 5 cells/cm 2. Cell assay was demonstrated by monitoring the fluorescence localization of calcein AM from 1 min to 10 days after reagent introduction. Confluent cell cultures were passaged within the microfluidic chambers using trypsin and successfully regrown, suggesting a stable culture environment suitable for continuous operation. The cell culture array could offer a platform for a wide range of assays with applications in drug screening, bioinformatics, and quantitative cell biology. © 2004 Wiley Periodicals, Inc.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Microfluidic Large-Scale Integration
Thorsen, T., Maerkl, S. J., & Quake, S. R. (2002) · Science · doi:10.1126/science.1076996 · Cited by 2,222
The role of bioreactors in tissue engineering
Martin, I., Wendt, D., & Heberer, M. (2004) · Trends in Biotechnology · doi:10.1016/j.tibtech.2003.12.001 · Cited by 1,215
Li Jeon, N., Baskaran, H., Dertinger, S. K. W., Whitesides, G. M., Van De Water, L., & Toner, M. (2002) · Nature Biotechnology · doi:10.1038/nbt712 · Cited by 917
Integration of Cell Culture and Microfabrication Technology
Park, T. H., & Shuler, M. L. (2003) · Biotechnology Progress · doi:10.1021/bp020143k · Cited by 473
A microfabricated array bioreactor for perfused 3D liver culture
Powers, M. J., Domansky, K., Kaazempur‐Mofrad, M. R., Kalezi, A., Capitano, A., Upadhyaya, A., Kurzawski, P., Wack, K. E., Stolz, D. B., Kamm, R., et al. (2002) · Biotechnology and Bioengineering · doi:10.1002/bit.10143 · Cited by 462
High-throughput and ultra-high-throughput screening: solution- and cell-based approaches
Sundberg, S. (2000) · Current Opinion in Biotechnology · doi:10.1016/s0958-1669(99)00051-8 · Cited by 455
Diffusion of Gases in Silicone Polymers: Molecular Dynamics Simulations
Charati, S. G., & Stern, S. A. (1998) · Macromolecules · doi:10.1021/ma980387e · Cited by 423
Microenvironment design considerations for cellular scale studies
Walker, G. M., Zeringue, H. C., & Beebe, D. J. (2004) · Lab on a Chip · doi:10.1039/b311214d · Cited by 388
Cell Culture in 3-Dimensional Microfluidic Structure of PDMS (polydimethylsiloxane)
Leclerc, E., Sakai, Y., & Fujii, T. (2003) · Biomedical Microdevices · doi:10.1023/a:1024583026925 · Cited by 324
Microfabrication and microfluidics for tissue engineering: state of the art and future opportunities
Andersson, H., & Berg, A. V. D. (2004) · Lab on a Chip · doi:10.1039/b314469k · Cited by 307
Development of a Microscale Cell Culture Analog To Probe Naphthalene Toxicity
Viravaidya, K., Sin, A., & Shuler, M. L. (2008) · Biotechnology Progress · doi:10.1021/bp0341996 · Cited by 305
Biosensors based on electropolymerized films: new trends
Cosnier, S. (2003) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-003-2131-7 · Cited by 259
Low-cost microbioreactor for high-throughput bioprocessing
Kostov, Y. V., Harms, P. D., Randers‐Eichhorn, L., & Rao, G. (2000) · Biotechnology and Bioengineering · Cited by 194
Cell-based assays and instrumentation for screening ion-channel targets
González, J. (1999) · Drug Discovery Today · doi:10.1016/s1359-6446(99)01383-5 · Cited by 178
HTS approaches to voltage-gated ion channel drug discovery
Denyer, J. C., Worley, J. F., Cox, B. J., et al. (1998) · Drug Discovery Today · doi:10.1016/s1359-6446(98)01199-4 · Cited by 101
Insect Cell Culture in Microfluidic Channels
Walker, G. M., Ozers, M. S., & Beebe, D. J. (2002) · Biomedical Microdevices · doi:10.1023/a:1016088128057 · Cited by 84
Microchip-based high-throughput screening analysis of combinatorial libraries
Khandurina, J., & Guttman, A. (2002) · Current Opinion in Chemical Biology · doi:10.1016/s1367-5931(02)00323-x · Cited by 78
Conway, B. R., Minor, L. K., Xu, J. Z., et al. (1999) · SLAS DISCOVERY · doi:10.1177/108705719900400207 · Cited by 75
Miraglia, S. J., Swartzman, E. E., Mellentin, J. D., Evangelista, L., Smith, C. J. S., Gunawan, I., Lohman, K. L., Goldberg, E. M., Manian, B. S., & Yuan, P.-M. (1999) · SLAS DISCOVERY · doi:10.1177/108705719900400407 · Cited by 66
Maffia, A. M., Kariv, I., & Oldenburg, K. R. (1999) · SLAS DISCOVERY · doi:10.1177/108705719900400307 · Cited by 59
Cited by
The origins and the future of microfluidics
Whitesides, G. M. (2006) · Nature · doi:10.1038/nature05058 · Cited by 9,687
El-Ali, J., Sorger, P. K., & Jensen, K. F. (2006) · Nature · doi:10.1038/nature05063 · Cited by 2,102
Microfluidics technology for manipulation and analysis of biological cells
Yi, C., Li, C.-W., Ji, S., & Yang, M. (2006) · Analytica Chimica Acta · doi:10.1016/j.aca.2005.12.037 · Cited by 478
Microfluidic cell culture systems for drug research
Wu, M.-H., Huang, S.-B., & Lee, G.-B. (2010) · Lab on a Chip · doi:10.1039/b921695b · Cited by 432
Marx, U. (2016) · ALTEX · doi:10.14573/altex.1603161 · Cited by 295
Metadata
- Authors
- Hung, P. J., Lee, P. J., Sabounchi, P., Lin, R., & Lee, L. P.
- Venue
- Biotechnology and Bioengineering
- Publisher
- Wiley
- Published
- 2004-12-03
- Volume
- 89
- Issue
- 1
- Pages
- 1-8
- ISSN
- 0006-3592 (ISSN-L)
- 1097-0290
- OpenAlex
- W2004441496
- Cited by
- 522
- References
- 20
- FWCI
- 12.11
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.