Abstract

Small‐scale upstream bioprocess development often occurs in flasks and multi‐well plates. These culturing platforms are often not equipped to accurately monitor and control critical process parameters; thus they may not yield conditions representative of manufacturing. In response, we and others have developed optical sensors that enable small‐scale process monitoring. Here we have compared two parameters critical to control in industrial cell culture, pH and dissolved oxygen (DO), measured with our optical sensors versus industrially accepted electrochemical probes. For both optical sensors, agreement with the corresponding electrochemical probe was excellent. The Pearson Correlations between the optical sensors and electrochemical probes were 98.7% and 99.7%, for DO and pH, respectively. Also, we have compared optical pH sensor performance in regular (320 mOsm/kg) and high‐osmolality (450 mOsm/kg) cell culture media to simulate the increase in osmolality in pH‐controlled cultures. Over a pH range of 6.38–7.98 the average difference in pH readings in the two media was 0.04 pH units. In summary, we have demonstrated that these optical sensors agree well with standard electrochemical probes. The accuracy of the optical probes demonstrates their ability to detect potential parameter drift that could have significant impact on growth, production kinetics, and protein product quality. We have also shown that an increase in osmolality that could result from controlling pH or operating the reactor in fed‐batch mode has an insignificant impact on the functionality of the pH patches. Biotechnol. Bioeng. 2007;97: 833–841. © 2007 Wiley Periodicals, Inc.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1002/bit.21320

Cites

2 of 2 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 2 references

Cited by

See all 106

Metadata

Authors
Hanson, M. A., Ge, X., Kostov, Y., Brorson, K. A., Moreira, A. R., & Rao, G.
Venue
Biotechnology and Bioengineering
Publisher
Wiley
Published
2007-05-24
Volume
97
Issue
4
Pages
833-841
ISSN
  • 0006-3592 (ISSN-L)
  • 1097-0290
OpenAlex
W2027556857
Cited by
106
References
2
FWCI
6.19
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Comparisons of optical pH and dissolved oxygen sensors with traditional electrochemical probes during mammalian cell culture. https://app.cochat.ai/papers/10.1002/bit.21320
The paper
Hanson, M. A., Ge, X., Kostov, Y., Brorson, K. A., Moreira, A. R., & Rao, G. (2007). Comparisons of optical pH and dissolved oxygen sensors with traditional electrochemical probes during mammalian cell culture. Biotechnology and Bioengineering. https://doi.org/10.1002/bit.21320

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.