CoChat

Genome‐scale analysis of Saccharomyces cerevisiae metabolism and ethanol production in fed‐batch culture

Open access
Hjersted, Jared L., Henson, Michael A., Mahadevan, Radhakrishnan · 2007 · Biotechnology and Bioengineering
Cited by 122

The DOI matches its Crossref record; 5 of the 5 references it cites were found in a registry or an index.

Abstract

A dynamic flux balance model based on a genome‐scale metabolic network reconstruction is developed for in silico analysis of Saccharomyces cerevisiae metabolism and ethanol production in fed‐batch culture. Metabolic engineering strategies previously identified for their enhanced steady‐state biomass and/or ethanol yields are evaluated for fed‐batch performance in glucose and glucose/xylose media. Dynamic analysis is shown to provide a single quantitative measure of fed‐batch ethanol productivity that explicitly handles the possible tradeoff between the biomass and ethanol yields. Productivity optimization conducted to rank achievable fed‐batch performance demonstrates that the genetic manipulation strategy and the fed‐batch operating policy should be considered simultaneously. A library of candidate gene insertions is assembled and directly screened for their achievable ethanol productivity in fed‐batch culture. A number of novel gene insertions with ethanol productivities identical to the best metabolic engineering strategies reported in previous studies are identified, thereby providing additional targets for experimental evaluation. The top performing gene insertions were substrate dependent, with the highest ranked insertions for glucose media yielding suboptimal performance in glucose/xylose media. The analysis results suggest that enhancements in biomass yield are most beneficial for the enhancement of fed‐batch ethanol productivity by recombinant xylose utilizing yeast strains. We conclude that steady‐state flux balance analysis is not sufficient to predict fed‐batch performance and that the media, genetic manipulations, and fed‐batch operating policy should be considered simultaneously to achieve optimal metabolite productivity. Biotechnol. Bioeng. 2007; 97: 1190–1204. © 2007 Wiley Periodicals, Inc.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1002/bit.21332

Cites

5 of 5 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 5 references

Cited by

Metadata

Authors
Hjersted, J. L., Henson, M. A., & Mahadevan, R.
Venue
Biotechnology and Bioengineering
Publisher
Wiley
Published
2007-01-22
Volume
97
Issue
5
Pages
1190-1204
ISSN
  • 0006-3592 (ISSN-L)
  • 1097-0290
OpenAlex
W2102961219
Cited by
122
References
5
FWCI
3.23
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.