Radial flow hepatocyte bioreactor using stacked microfabricated grooved substrates
The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
Bioartificial liver (BAL) devices with fully functioning hepatocytes have the potential to provide temporary hepatic support for patients with liver failure. The goal of this study was to optimize the flow environment for the cultured hepatocytes in a stacked substrate, radial flow bioreactor. Photolithographic techniques were used to microfabricate concentric grooves onto the underlying glass substrates. The microgrooves served to protect the seeded hepatocytes from the high shear stresses caused by the volumetric flow rates necessary for adequate convective oxygen delivery. Finite element analysis was used to analyze the shear stresses and oxygen concentrations in the bioreactor. By employing high volumetric flow rates, sufficient oxygen supply to the hepatocytes was possible without an integrated oxygen permeable membrane. To implement this concept, 18 microgrooved glass substrates, seeded with rat hepatocytes cocultured with 3T3‐J2 fibroblasts, were stacked in the bioreactor, creating a channel height of 100 µm between each substrate. In this bioreactor configuration, liver‐specific functions (i.e., albumin and urea synthesis rates) of the hepatocytes remained stable over 5 days of perfusion, and were significantly increased compared to those in the radial flow bioreactor with stacked substrates without microgrooves. This study suggests that this radial flow bioreactor with stacked microgrooved substrates is scalable and may have potential as a BAL device in the treatment of liver failure. Biotechnol. Bioeng. 2008;99: 455–467. © 2007 Wiley Periodicals, Inc.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Flow-mediated endothelial mechanotransduction
Davies, P. F. (1995) · Physiological Reviews · doi:10.1152/physrev.1995.75.3.519 · Cited by 2,802
Cited by
Godoy, P., Hewitt, N. J., Albrecht, U., Andersen, M. E., Ansari, N., Bhattacharya, S., Bode, J. G., Bolleyn, J., Borner, C., Böttger, J., et al. (2013) · Archives of Toxicology · doi:10.1007/s00204-013-1078-5 · Cited by 1,280
Badylak, S. F., Taylor, D., & Uygun, K. (2011) · Annual Review of Biomedical Engineering · doi:10.1146/annurev-bioeng-071910-124743 · Cited by 1,041
Design of artificial extracellular matrices for tissue engineering
Kim, B.-S., Park, I.-K., Hoshiba, T., Jiang, H.-L., Choi, Y.-J., Akaike, T., & Cho, C.-S. (2011) · Progress in Polymer Science · doi:10.1016/j.progpolymsci.2010.10.001 · Cited by 296
Marx, U. (2016) · ALTEX · doi:10.14573/altex.1603161 · Cited by 295
“ALTEX 33(3), 2016 280 hepatocytes (Carraro et al., 2008; Goral et al., 2010; Ho et al., 2006; Leclerc et al., 2004; Lee et al., 2007b; Park et al., 2008; Powers et al., 2002; Toh et al., 2007, 2009), neurons (Rhee et al.”
Engineering Liver Microtissues for Disease Modeling and Regenerative Medicine
Huang, D. (., Gibeley, S. B., Xu, C., Xiao, Y., Celik, O., Ginsberg, H. N., & Leong, K. W. (2020) · Advanced Functional Materials · doi:10.1002/adfm.201909553 · Cited by 65
Metadata
- Authors
- Park, J., Li, Y., Berthiaume, F., Toner, M., Yarmush, M. L., & Tilles, A. W.
- Venue
- Biotechnology and Bioengineering
- Publisher
- Wiley
- Published
- 2007-07-11
- Volume
- 99
- Issue
- 2
- Pages
- 455-467
- ISSN
- 0006-3592 (ISSN-L)
- 1097-0290
- OpenAlex
- W2086220382
- Cited by
- 90
- References
- 1
- FWCI
- 6.12
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Radial flow hepatocyte bioreactor using stacked microfabricated grooved substrates. https://app.cochat.ai/papers/10.1002/bit.21572
- The paper
- Park, J., Li, Y., Berthiaume, F., Toner, M., Yarmush, M. L., & Tilles, A. W. (2008). Radial flow hepatocyte bioreactor using stacked microfabricated grooved substrates. Biotechnology and Bioengineering. https://doi.org/10.1002/bit.21572
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.