CoChat

Microfluidic biochip for the perifusion of precision‐cut rat liver slices for metabolism and toxicology studies

van Midwoud, Paul M., Groothuis, Geny M.M., Merema, Marjolijn T., Verpoorte, Elisabeth · 2010 · Biotechnology and Bioengineering
Cited by 135

The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.

Abstract

Early detection of kinetic, metabolic, and toxicity (ADME‐Tox) profiles for new drug candidates is of crucial importance during drug development. This article describes a novel in vitro system for the incubation of precision‐cut liver slices (PCLS) under flow conditions, based on a poly(dimethylsiloxane) (PDMS) device containing 25‐µL microchambers for integration of the slices. The microdevice is coupled to a perifusion system, which enables a constant delivery of nutrients and oxygen and a continuous removal of waste products. Both a highly controlled incubation environment and high metabolite detection sensitivity could be achieved using microfluidics. Liver slices were viable for at least 24 h in the microdevice. The compound, 7‐ethoxycoumarin (7‐EC), was chosen to test metabolism, since its metabolism includes both phase I and phase II metabolism and when tested in the conventional well plate system, correlates well with the in vivo situation (De Kanter et al. 2004. Xenobiotica 34(3): 229–241.). The metabolic rate of 7‐EC was found to be 214 ± 5 pmol/min/mg protein in the microdevice, comparable to well plates, and was constant over time for at least 3 h. This perifusion system better mimics the in vivo situation, and has the potential to significantly contribute to drug metabolism and toxicology studies of novel chemical entities. Biotechnol. Bioeng. 2010;105: 184–194. © 2009 Wiley Periodicals, Inc.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1002/bit.22516

Cites

2 of 2 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 2 references

Cited by

See all 135

Metadata

Authors
van Midwoud, P. M., Groothuis, G. M. M., Merema, M. T., & Verpoorte, E.
Venue
Biotechnology and Bioengineering
Publisher
Wiley
Published
2009-10-08
Volume
105
Issue
1
Pages
184-194
ISSN
  • 0006-3592 (ISSN-L)
  • 1097-0290
OpenAlex
W2139542130
Cited by
135
References
2
FWCI
5.05
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Microfluidic biochip for the perifusion of precision‐cut rat liver slices for metabolism and toxicology studies. https://app.cochat.ai/papers/10.1002/bit.22516
The paper
van Midwoud, P. M., Groothuis, G. M. M., Merema, M. T., & Verpoorte, E. (2010). Microfluidic biochip for the perifusion of precision‐cut rat liver slices for metabolism and toxicology studies. Biotechnology and Bioengineering. https://doi.org/10.1002/bit.22516

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.