Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 373

The DOI matches its Crossref record; 50 of the 50 references it cites were found in a registry or an index.

Influence of substrate stiffness on the phenotype of heart cells

Bhana, Bashir, Iyer, Rohin K., Chen, Wen Li Kelly, Zhao, Ruogang, Sider, Krista L., Likhitpanichkul, Morakot, Simmons, Craig A., Radisic, Milica·2010·Biotechnology and Bioengineering

Abstract

Adult cardiomyocytes (CM) retain little capacity to regenerate, which motivates efforts to engineer heart tissues that can emulate the functional and mechanical properties of native myocardium. Although the effects of matrix stiffness on individual CM have been explored, less attention was devoted to studies at the monolayer and the tissue level. The purpose of this study was to characterize the influence of substrate mechanical stiffness on the heart cell phenotype and functional properties. Neonatal rat heart cells were seeded onto collagen‐coated polyacrylamide (PA) substrates with Young's moduli of 3, 22, 50, and 144 kPa. Collagen‐coated glass coverslips without PA represented surfaces with effectively “infinite” stiffness. The local elastic modulus of native neonatal rat heart tissue was measured to range from 4.0 to 11.4 kPa (mean value of 6.8 kPa) and for native adult rat heart tissue from 11.9 to 46.2 kPa (mean value of 25.6 kPa), motivating our choice of the above PA gel stiffness. Overall, by 120 h of cultivation, the lowest stiffness PA substrates (3 kPa) exhibited the lowest excitation threshold (ET; 3.5 ± 0.3 V/cm), increased troponin I staining (52% positively stained area) but reduced cell density, force of contraction (0.18 ± 0.1 mN/mm 2), and cell elongation (aspect ratio = 1.3–1.4). Higher stiffness (144 kPa) PA substrates exhibited reduced troponin I staining (30% positively stained area), increased fibroblast density (70% positively stained area), and poor electrical excitability. Intermediate stiffness PA substrates of stiffness comparable to the native adult rat myocardium (22–50 kPa) were found to be optimal for heart cell morphology and function, with superior elongation (aspect ratio > 4.3), reasonable ET (ranging from 3.95 ± 0.8 to 4.4 ± 0.7 V/cm), high contractile force development (ranging from 0.52 ± 0.2 to 1.60 ± 0.6 mN/mm 2), and well‐developed striations, all consistent with a differentiated phenotype. Biotechnol. Bioeng. 2010;105: 1148–1160. © 2009 Wiley Periodicals, Inc.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1002/bit.22647

Cites

50 of 50 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 50 references

Cited by

See all 373

Metadata

Authors
Bhana, B., Iyer, R. K., Chen, W. L. K., Zhao, R., Sider, K. L., Likhitpanichkul, M., Simmons, C. A., & Radisic, M.
Venue
Biotechnology and Bioengineering
Publisher
Wiley
Published
2010-02
Volume
105
Issue
6
Pages
1148-1160
ISSN
  • 0006-3592 (ISSN-L)
  • 1097-0290
OpenAlex
W2126875247
Cited by
373
References
50
FWCI
7.27
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Influence of substrate stiffness on the phenotype of heart cells. https://app.cochat.ai/papers/10.1002/bit.22647
The paper
Bhana, B., Iyer, R. K., Chen, W. L. K., Zhao, R., Sider, K. L., Likhitpanichkul, M., Simmons, C. A., & Radisic, M. (2010). Influence of substrate stiffness on the phenotype of heart cells. Biotechnology and Bioengineering. https://doi.org/10.1002/bit.22647

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.