A low shear stress modular bioreactor for connected cell culture under high flow rates
The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Abstract
A generic “system on a plate” modular multicompartmental bioreactor array which enables microwell protocols to be transferred directly to the bioreactor modules, without redesign of cell culture experiments or protocols is described. The modular bioreactors are simple to assemble and use and can be easily compared with standard controls since cell numbers and medium volumes are quite similar. Starting from fluid dynamic and mass transport considerations, a modular bioreactor chamber was first modeled and then fabricated using “milli‐molding,” a technique adapted from soft lithography. After confirming that the shear stress was extremely low in the system in the range of useful flow rates, the bioreactor chambers were tested using hepatocytes. The results show that the bioreactor chambers can increase or maintain cell viability and function when the flow rates are below 500 µL/min, corresponding to wall shear stresses of 10−5 Pa or less at the cell culture surface. Biotechnol. Bioeng. 2010; 106: 127–137. © 2010 Wiley Periodicals, Inc.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
A General Model for the Origin of Allometric Scaling Laws in Biology
West, G. B., Brown, J. H., & Enquist, B. J. (1997) · Science · doi:10.1126/science.276.5309.122 · Cited by 5,016
Functional behavior of primary rat liver cells in a three-dimensional perfused microarray bioreactor
Powers, M. J., Janigian, D. M., Wack, K. E., Baker, C. S., Stolz, D. B., & Griffith, L. G. (2002) · Tissue Engineering · doi:10.1089/107632702760184745 · Cited by 234 · cited 3×
“Several reports describe the effects of flow and shear stress on hepatocyte cultures (Mufti and Shuler, 1995; Nakatsuka et al., 2006; Powers et al., 2002b; Tanaka et al., 2006).”
BackgroundResult
Cited by
On being the right size: scaling effects in designing a human-on-a-chip
Moraes, C., Labuz, J. M., Leung, B. M., Inoue, M., Chun, T.-H., & Takayama, S. (2013) · Integrative Biology · doi:10.1039/c3ib40040a · Cited by 134
Mechanostructure and composition of highly reproducible decellularized liver matrices
Mattei, G., Di Patria, V., Tirella, A., Alaimo, A., Elia, G., Corti, A., Paolicchi, A., & Ahluwalia, A. (2014) · Acta Biomaterialia · doi:10.1016/j.actbio.2013.10.023 · Cited by 78
“A number of scientists have suggested that the target has been elusive because hepatocytes in vitro are deprived of the multi-parametric, multi-stimuli in vivo milieu [1].”
Self-citationSung, J. H., Wang, Y., & Shuler, M. L. (2019) · APL Bioengineering · doi:10.1063/1.5097675 · Cited by 66
3D Cultivation Techniques for Primary Human Hepatocytes
Bachmann, A., Moll, M., Gottwald, E., Nies, C., Zantl, R., Wagner, H., Burkhardt, B., Sánchez, J., Ladurner, R., Thasler, W., et al. (2015) · Microarrays · doi:10.3390/microarrays4010064 · Cited by 59
In vitro Liver Zonation of Primary Rat Hepatocytes
Tomlinson, L., Hyndman, L., Firman, J. W., Bentley, R., Kyffin, J. A., Webb, S. D., McGinty, S., & Sharma, P. (2019) · Frontiers in Bioengineering and Biotechnology · doi:10.3389/fbioe.2019.00017 · Cited by 38
Metadata
- Authors
- Mazzei, D., Guzzardi, M. A., Giusti, S., & Ahluwalia, A.
- Venue
- Biotechnology and Bioengineering
- Publisher
- Wiley
- Published
- 2010-03-08
- Volume
- 106
- Issue
- 1
- Pages
- 127-137
- ISSN
- 0006-3592 (ISSN-L)
- 1097-0290
- OpenAlex
- W2110850188
- Cited by
- 97
- References
- 2
- FWCI
- 2.73
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: A low shear stress modular bioreactor for connected cell culture under high flow rates. https://app.cochat.ai/papers/10.1002/bit.22671
- The paper
- Mazzei, D., Guzzardi, M. A., Giusti, S., & Ahluwalia, A. (2010). A low shear stress modular bioreactor for connected cell culture under high flow rates. Biotechnology and Bioengineering. https://doi.org/10.1002/bit.22671
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.