A pumpless multi‐organ‐on‐a‐chip (MOC) combined with a pharmacokinetic–pharmacodynamic (PK–PD) model
The DOI matches its Crossref record; 12 of the 12 references it cites were found in a registry or an index.
Abstract
A multi‐organ‐on‐a‐chip (MOC), also known as a human‐on‐a‐chip, aims to simulate whole body response to drugs by connecting microscale cell cultures of multiple tissue types via fluidic channels and reproducing the interaction between them. While several studies have demonstrated the usefulness of MOC at a proof‐of‐concept level, improvements are needed to enable wider acceptance of such systems; ease of use for general biological researchers, and a mathematical framework to design and interpret the MOC systems. Here, we introduce a pumpless, user‐friendly MOC which can be easily assembled and operated, and demonstrate the use of a PK–PD model for interpreting drug's action inside the MOC. The metabolism‐dependent anticancer activity of a flavonoid, luteolin, was evaluated in a two‐compartment MOC containing the liver (HepG2) and the tumor (HeLa) cells, and the observed anticancer activity was significantly weaker than that anticipated from a well plate study. Simulation of a PK–PD model revealed that simultaneous metabolism and tumor‐killing actions likely resulted in a decreased anti‐cancer effect. Our work demonstrates that the combined platform of mathematical PK–PD model and an experimental MOC can be a useful tool for gaining an insight into the mechanism of action of drugs with interactions between multiple organs. Biotechnol. Bioeng. 2017;114: 432–443. © 2016 Wiley Periodicals, Inc.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
A General Model for the Origin of Allometric Scaling Laws in Biology
West, G. B., Brown, J. H., & Enquist, B. J. (1997) · Science · doi:10.1126/science.276.5309.122 · Cited by 5,016
Rapid casting of patterned vascular networks for perfusable engineered three-dimensional tissues
Miller, J. S., Stevens, K. R., Yang, M. T., Baker, B. M., Nguyen, D.-H. T., Cohen, D. M., Toro, E., Chen, A. A., Galie, P. A., Yu, X., et al. (2012) · Nature Materials · doi:10.1038/nmat3357 · Cited by 1,917
Microscale culture of human liver cells for drug development
Khetani, S. R., & Bhatia, S. N. (2008) · Nature Biotechnology · doi:10.1038/nbt1361 · Cited by 1,219
Distribution and biological activities of the flavonoid luteolin
Lopez-Lazaro, M. (2009) · Mini-Reviews in Medicinal Chemistry · doi:10.2174/138955709787001712 · Cited by 1,106
Maschmeyer, I., Lorenz, A. K., Schimek, K., Hasenberg, T., Ramme, A. P., Hübner, J., Lindner, M., Drewell, C., Bauer, S., Thomas, A., et al. (2015) · Lab on a Chip · doi:10.1039/c5lc00392j · Cited by 861
Re-Examination of the “3/4-Law” of Metabolism
DODDS, P. S., ROTHMAN, D. H., & WEITZ, J. S. (2001) · Journal of Theoretical Biology · doi:10.1006/jtbi.2000.2238 · Cited by 589
Wagner, I., Materne, E.-M., Brincker, S., Süßbier, U., Frädrich, C., Busek, M., Sonntag, F., Sakharov, D. A., Trushkin, E. V., Tonevitsky, A. G., et al. (2013) · Lab on a Chip · doi:10.1039/c3lc50234a · Cited by 476 · cited 2×
“, 2010b), lung-liver-fat tissues (Viravaidya and Shuler, 2004), and liver-skin (Wagner et al., 2013) .”
Multi-Organ toxicity demonstration in a functional human in vitro system composed of four organs
Oleaga, C., Bernabini, C., Smith, A. S. T., Srinivasan, B., Jackson, M., McLamb, W., Platt, V., Bridges, R., Cai, Y., Santhanam, N., et al. (2016) · Scientific Reports · doi:10.1038/srep20030 · Cited by 442 · cited 1×
“These systems successfully showed that multiple cells can be cultured and interact with one another on a single chip while connected with fluidic channels (Oleaga et al., 2016).”
BackgroundEsch, M. B., Mahler, G. J., Stokol, T., & Shuler, M. L. (2014) · Lab Chip · doi:10.1039/c4lc00371c · Cited by 281 · cited 2×
“, 2004), several research groups have reported MOC devices, containing the gut-liver (Esch et al., 2014; van Midwoud et al., 2010), liver-fat-blood vessel (Iori et al.”
Backgroundvan Midwoud, P. M., Merema, M. T., Verpoorte, E., & Groothuis, G. M. M. (2010) · Lab on a Chip · doi:10.1039/c0lc00043d · Cited by 203
On being the right size: scaling effects in designing a human-on-a-chip
Moraes, C., Labuz, J. M., Leung, B. M., Inoue, M., Chun, T.-H., & Takayama, S. (2013) · Integrative Biology · doi:10.1039/c3ib40040a · Cited by 134
Microengineered Liver Tissues for Drug Testing
Khetani, S. R., Berger, D. R., Ballinger, K. R., Davidson, M. D., Lin, C., & Ware, B. R. (2015) · SLAS Technology · doi:10.1177/2211068214566939 · Cited by 116 · cited 2×
“Based on recent advances, various organ-on-a-chip microsystems have been developed, including the liver (Khetani et al., 2015), heart (Lee et al., 2015), gastrointestinal tract (Sant et al., 2012), the brain (Pamies et al., 2014), and the kidney (Kim and Roy, 2013).”
Background
Cited by
Modelling cancer in microfluidic human organs-on-chips
Sontheimer-Phelps, A., Hassell, B. A., & Ingber, D. E. (2019) · Nature Reviews Cancer · doi:10.1038/s41568-018-0104-6 · Cited by 906
Organ-on-a-chip: recent breakthroughs and future prospects
Wu, Q., Liu, J., Wang, X., Feng, L., Wu, J., Zhu, X., Wen, W., & Gong, X. (2020) · BioMedical Engineering OnLine · doi:10.1186/s12938-020-0752-0 · Cited by 701
Delivery of oligonucleotide‐based therapeutics: challenges and opportunities
Hammond, S. M., Aartsma‐Rus, A., Alves, S., Borgos, S. E., Buijsen, R. A. M., Collin, R. W. J., Covello, G., Denti, M. A., Desviat, L. R., Echevarría, L., et al. (2021) · EMBO Molecular Medicine · doi:10.15252/emmm.202013243 · Cited by 388
Organ-on-a-chip platforms: a convergence of advanced materials, cells, and microscale technologies
Ahadian, S., Civitarese, R., Bannerman, D., Mohammadi, M. H., Lu, R., Wang, E., Davenport‐Huyer, L., Lai, B., Zhang, B., Zhao, Y., et al. (2018) · Advanced Healthcare Materials · doi:10.1002/adhm.201700506 · Cited by 315
Recent Advances in Body-on-a-Chip Systems
Sung, J. H., Wang, Y. I., Narasimhan Sriram, N., Jackson, M., Long, C., Hickman, J. J., & Shuler, M. L. (2019) · Analytical Chemistry · doi:10.1021/acs.analchem.8b05293 · Cited by 268
Self-citation
Metadata
- Authors
- Lee, H., Kim, D. S., Ha, S. K., Choi, I., Lee, J. M., & Sung, J. H.
- Venue
- Biotechnology and Bioengineering
- Publisher
- Wiley
- Published
- 2016-09-14
- Volume
- 114
- Issue
- 2
- Pages
- 432-443
- ISSN
- 0006-3592 (ISSN-L)
- 1097-0290
- OpenAlex
- W2507329958
- Cited by
- 124
- References
- 12
- FWCI
- 6.38
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.