Process monitoring of virus‐like particle reassembly by diafiltration with UV/Vis spectroscopy and light scattering
Open accessThe DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Abstract
Virus‐like particles (VLPs) have shown great potential as biopharmaceuticals in the market and in clinics. Nonenveloped, in vivo assembled VLPs are typically disassembled and reassembled in vitro to improve particle stability, homogeneity, and immunogenicity. At the industrial scale, cross‐flow filtration (CFF) is the method of choice for performing reassembly by diafiltration. Here, we developed an experimental CFF setup with an on‐line measurement loop for the implementation of process analytical technology (PAT). The measurement loop included an ultraviolet and visible (UV/Vis) spectrometer as well as a light scattering photometer. These sensors allowed for monitoring protein concentration, protein tertiary structure, and protein quaternary structure. The experimental setup was tested with three Hepatitis B core Antigen (HBcAg) variants. With each variant, three reassembly processes were performed at different transmembrane pressures (TMPs). While light scattering provided information on the assembly progress, UV/Vis allowed for monitoring the protein concentration and the rate of VLP assembly based on the microenvironment of Tyrosine‐132. VLP formation was verified by off‐line dynamic light scattering (DLS) and transmission electron microscopy (TEM). Furthermore, the experimental results provided evidence of aggregate‐related assembly inhibition and showed that off‐line size‐exclusion chromatography does not provide a complete picture of the particle content. Finally, a Partial‐Least Squares (PLS) model was calibrated to predict VLP concentrations in the process solution. values of 0.947–0.984 were reached for the three HBcAg variants. In summary, the proposed experimental setup provides a powerful platform for developing and monitoring VLP reassembly steps by CFF.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
PAGE, E. S. (1954) · Biometrika · doi:10.1093/biomet/41.1-2.100 · Cited by 5,739
SIMPLS: An alternative approach to partial least squares regression
de Jong, S. (1993) · Chemometrics and Intelligent Laboratory Systems · doi:10.1016/0169-7439(93)85002-x · Cited by 1,905
Alexander, C. G., Jürgens, M. C., Shepherd, D. A., Freund, S. M. V., Ashcroft, A. E., & Ferguson, N. (2013) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1308846110 · Cited by 85
Cited by
Wasalathanthri, D. P., Rehmann, M. S., Song, Y., Gu, Y., Mi, L., Shao, C., Chemmalil, L., Lee, J., Ghose, S., Borys, M. C., et al. (2020) · Biotechnology and Bioengineering · doi:10.1002/bit.27461 · Cited by 177
Rolinger, L., Rüdt, M., & Hubbuch, J. (2020) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-020-02407-z · Cited by 126
Self-citationRolinger, L., Rüdt, M., Diehm, J., Chow-Hubbertz, J., Heitmann, M., Schleper, S., & Hubbuch, J. (2020) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-019-02318-8 · Cited by 46
Self-citation
Metadata
- Authors
- Rüdt, M., Vormittag, P., Hillebrandt, N., & Hubbuch, J.
- Venue
- Biotechnology and Bioengineering
- Publisher
- Wiley
- Published
- 2019-02-20
- Volume
- 116
- Issue
- 6
- Pages
- 1366-1379
- ISSN
- 0006-3592 (ISSN-L)
- 1097-0290
- OpenAlex
- W2914780528
- Cited by
- 38
- References
- 3
- FWCI
- 1.50
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Process monitoring of virus‐like particle reassembly by diafiltration with UV/Vis spectroscopy and light scattering. https://app.cochat.ai/papers/10.1002/bit.26935
- The paper
- Rüdt, M., Vormittag, P., Hillebrandt, N., & Hubbuch, J. (2019). Process monitoring of virus‐like particle reassembly by diafiltration with UV/Vis spectroscopy and light scattering. Biotechnology and Bioengineering. https://doi.org/10.1002/bit.26935
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.