Membrane mass spectrometer inlet for quantitation of nitric oxide
The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.
Abstract
Nitric oxide (NO) is an important physiological and biochemical messenger that may be involved in endogenous carcinogenesis and cell toxicity via formation of N-nitroso compounds or direct DNA damage by nitrosating agents arising from the reaction of NO with O2. To study the reaction of NO with O2 in model systems and the formation and disappearance of NO in more physiological systems such as cell cultures, we adapted and optimized a membrane mass spectrometer inlet specifically for such analyses. The inlet consisted of Silastic tubing inserted into a Swagelok 'tee', which was attached to the mass spectrometer via the tuning probe. Kinetics of NO disappearance can be followed under electron impact conditions until NO2 interferes via the formation of NO+ during fragmentation of NO2+. The aqueous NO concentration for minimum detection was determined to be 1.4 microM. The inlet response time to step changes in aqueous NO concentrations was 7.0 s, fast enough to permit real-time measurements of aqueous NO changes upon addition of O2. Finally, the depletion of aqueous NO was observed in the presence of O2. The relative steady state responses of inlets designed for gas or aqueous samples, and their relative response times, are explained by an analysis based on mass transfer theory.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Rajfer, J., Aronson, W. J., Bush, P. A., Dorey, F. J., & Ignarro, L. J. (1992) · New England Journal of Medicine · doi:10.1056/nejm199201093260203 · Cited by 1,006
Green, L. C., Ruiz de Luzuriaga, K., Wagner, D. A., Rand, W., Istfan, N., Young, V. R., & Tannenbaum, S. R. (1981) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.78.12.7764 · Cited by 665
Self-citationL-Arginine is a precursor for nitrate biosynthesis in humans
Leaf, C. D., Wishnok, J. S., & Tannenbaum, S. R. (1989) · Biochemical and Biophysical Research Communications · doi:10.1016/0006-291x(89)92325-5 · Cited by 129
Self-citationMechanisms for nitrite loss from the stomach
Licht, W. R., Schultz, D. S., Fox, J. G., Tannenbaum, S. R., & Deen, W. M. (1986) · Carcinogenesis · doi:10.1093/carcin/7.10.1681 · Cited by 12
Self-citation
Cited by
Nitric oxide, superoxide, and peroxynitrite: the good, the bad, and ugly
Beckman, J. S., & Koppenol, W. H. (1996) · American Journal of Physiology-Cell Physiology · doi:10.1152/ajpcell.1996.271.5.c1424 · Cited by 5,513
Nunoshiba, T., deRojas-Walker, T., Wishnok, J. S., Tannenbaum, S. R., & Demple, B. (1993) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.90.21.9993 · Cited by 310
Self-citationMembrane introduction Mass Spectrometry: Trends and applications
Johnson, R. C., Cooks, R. G., Allen, T. M., Cisper, M. E., & Hemberger, P. H. (2000) · Mass Spectrometry Reviews · doi:10.1002/(sici)1098-2787(2000)19:1<1::aid-mas1>3.0.co;2-y · Cited by 256
Iijima, K. (2003) · Carcinogenesis · doi:10.1093/carcin/bgg168 · Cited by 81
Winter, J. W., Paterson, S., Scobie, G., Wirz, A., Preston, T., & McColl, K. E. L. (2007) · Gastroenterology · doi:10.1053/j.gastro.2007.04.047 · Cited by 59
Metadata
- Authors
- Lewis, R. S., Deen, W. M., Tannenbaum, S. R., & Wishnok, J. S.
- Venue
- Biological Mass Spectrometry
- Publisher
- Wiley
- Published
- 1993-01
- Volume
- 22
- Issue
- 1
- Pages
- 45-52
- ISSN
- 1076-5174 (ISSN-L)
- 1052-9306
- 1096-9888
- OpenAlex
- W2011469272
- Cited by
- 29
- References
- 4
- FWCI
- 1.97
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Membrane mass spectrometer inlet for quantitation of nitric oxide. https://app.cochat.ai/papers/10.1002/bms.1200220106
- The paper
- Lewis, R. S., Deen, W. M., Tannenbaum, S. R., & Wishnok, J. S. (1993). Membrane mass spectrometer inlet for quantitation of nitric oxide. Biological Mass Spectrometry. https://doi.org/10.1002/bms.1200220106
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.