A multivariate calibration procedure for UV/VIS spectrometric monitoring of BHK‐21 cell metabolism and growth
The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Abstract
Monitoring mammalian cell culture with UV–vis spectroscopy has not been widely explored. The aim of this work was to calibrate Partial Least Squares (PLS) models from off‐line UV–vis spectral data in order to predict some nutrients and metabolites, as well as viable cell concentrations for mammalian cell bioprocess using phenol red in culture medium. The BHK‐21 cell line was used as a mammalian cell model. Spectra of samples taken from batches performed at different dissolved oxygen concentrations (10, 30, 50, and 70% air saturation), in two bioreactor configurations and with two strategies to control pH were used to calibrate and validate PLS models. Glutamine, glutamate, glucose, and lactate concentrations were suitably predicted by means of this strategy. Especially for glutamine and glucose concentrations, the prediction error averages were lower than 0.50 ± 0.10 mM and 2.21 ± 0.16 mM, respectively. These values are comparable with those previously reported using near infrared and Raman spectroscopy in conjunction with PLS. However, viable cell concentration models need to be improved. The present work allows for UV–vis at‐line sensor development, decrease cost related to nutrients and metabolite quantifications and establishment of fed‐batch feeding schemes. © 2013 American Institute of Chemical Engineers Biotechnol. Prog., 30:241–248, 2014
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“In fermentation broths, distinguishing between different absorbing species is challenging due to overlapping spectra, and without additional data such as retention time or complementary spectral information, identifying and quantifying individual compounds is difficult.”
From Spectroscopic Advances in Real Time Monitoring of Pharmaceutical Bioprocesses: A Review of Vibrational and Fluorescence Techniques (2025) · cites this paper as [52]
In the citing paper
“Components like phenol red in culture media can further interfere with UV/Vis readings, necessitating complex data analysis techniques for correction [52].”
From Spectroscopic Advances in Real Time Monitoring of Pharmaceutical Bioprocesses: A Review of Vibrational and Fluorescence Techniques (2025) · cites this paper as [52]
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Abu‐Absi, N. R., Kenty, B. M., Cuellar, M. E., Borys, M. C., Sakhamuri, S., Strachan, D. J., Hausladen, M. C., & Li, Z. J. (2011) · Biotechnology and Bioengineering · doi:10.1002/bit.23023 · Cited by 322 · cited 3×
“to the values reported for a PLS model based on near infrared spectral data in mammalian or insect culture media as well as those for mammalian cell cultures using Raman spectroscopy.(9,11,29) Table 3.”
MethodBioreactor monitoring with spectroscopy and chemometrics: a review
Lourenço, N. D., Lopes, J. A., Almeida, C. F., Sarraguça, M. C., & Pinheiro, H. M. (2012) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-012-6073-9 · Cited by 275 · cited 4×
“Additionally, an at-line UV–vis sensor could be also developed based on the current availability of UV-grade optical fibers, sensitive and cheaper array detectors, together with PLS technique.(10) The utilization of PLS technique associated to UV–vis spectra from samples of mammalian cell cultures using phenol red as…”
BackgroundMethodInfluentialOn-line infrared spectroscopy for bioprocess monitoring
Landgrebe, D., Haake, C., Höpfner, T., Beutel, S., Hitzmann, B., Scheper, T., Rhiel, M., & Reardon, K. F. (2010) · Applied Microbiology and Biotechnology · doi:10.1007/s00253-010-2743-8 · Cited by 134
Research works printed but not linked: 27
- 10.1016/j.biotechadv.2009.05.003 · DOI · Paper page
- 10.1186/1475-2859-8-42 · DOI
- 10.1016/j.jprocont.2008.11.007 · DOI
- 10.1002/jctb.691 · DOI · Paper page
- 10.1002/bit.21523 · DOI
- Logan D, 2011, A Biomass monitor for disposable bioreactors, Bioprocess Int, 9, 48
- 10.1016/j.procbio.2010.05.005 · DOI
- 10.1002/(SICI)1097-0290(19970705)55:1<11::AID-BIT2>3.0.CO;2-# · DOI · Paper page
- 10.1002/btpr.561 · DOI
- 10.1002/jctb.2576 · DOI
- 10.1002/bit.21088 · DOI
- Auniņš JG, 2010, Encyclopedia of Industrial Biotechnology: Bioprocess, Bioseparation, and Cell Technology, 1
- 10.1016/S0014-5793(01)02707-7 · DOI
- 10.1002/9780470089941.et0403s5 · doi:10.1002/9780470089941.et0403s5
- 10.1002/9780470649367 · DOI · Paper page
- 10.1016/j.jbiotec.2004.03.028 · DOI · Paper page
- 10.2166/wst.2003.0086 · doi:10.2166/wst.2003.0086
- 10.1002/btpr.280 · DOI · Paper page
- 10.1002/9780470689592.ch4 · DOI
- 10.1007/s10616‐013‐9612‐0 · DOI
- 10.1016/j.medengphy.2005.07.016 · DOI
- 10.1007/s002530051435 · DOI
- 10.1016/S0141-0229(00)00151-4 · DOI · Paper page
- 10.1002/btpr.1664 · DOI · Paper page
- 10.1016/j.addr.2011.07.006 · DOI · Paper page
- 10.1002/bit.10093 · DOI · Paper page
- Hoffman TL, 2006, Cell Biology. A Laboratory Handbook, 21
Cited by
Modern Sensor Tools and Techniques for Monitoring, Controlling, and Improving Cell Culture Processes
Reyes, S. J., Durocher, Y., Pham, P. L., & Henry, O. (2022) · Processes · doi:10.3390/pr10020189 · Cited by 130
Sensors and Techniques for On-Line Determination of Cell Viability in Bioprocess Monitoring
Rösner, L., Walter, F., Ude, C., John, G., & Beutel, S. (2022) · Bioengineering · doi:10.3390/bioengineering9120762 · Cited by 42
“Since spectroscopic methods are usually not focused on single components but provide large sets of data, relevant data need to be extracted and mathematical procedures for data mining are mandatory [27].”
BackgroundMishra, A., Aghaee, M., Tamer, I. M., & Budman, H. (2025) · Spectroscopy Journal · doi:10.3390/spectroscj3020012 · Cited by 19
“Components like phenol red in culture media can further interfere with UV/Vis readings, necessitating complex data analysis techniques for correction [52].”
Metadata
- Authors
- Leme, J., Fernández Núñez, E. G., de Almeida Parizotto, L., Chagas, W. A., dos Santos, E. S., Caricati, A. T. P., de Rezende, A. G., da Costa, B. L. V., Monteiro, D. C. V., Boldorini, V. L. L., Jorge, S. A. C., Astray, R. M., Pereira, C. A., Caricati, C. P., & Tonso, A.
- Affiliations
- Laboratório Especial de Pesquisa e Desenvolvimento em Imunológicos Veterinários, Instituto Butantan. Av. Vital Brasil, 1500 Butantã 05503‐900 São Paulo SP–Brazil
- Dept. de Engenharia Química, Laboratório de Células Animais, Escola Politécnica Universidade de São Paulo. Av. Prof. Luciano Gualberto trav. 3, 380, Butantã 05508‐900 São Paulo SP–Brazil
- Laboratório de Imunologia Viral Instituto Butantan. Av. Vital Brasil 1500 Butantã 05503‐900 São Paulo SP–Brazil
- Venue
- Biotechnology Progress
- Publisher
- Wiley
- Published
- 2013-12-30
- Volume
- 30
- Issue
- 1
- Pages
- 241-248
- ISSN
- 8756-7938
- 1520-6033
- Cited by
- 14
- References
- 3
- Language
- en
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.