Mid‐infrared spectroscopy‐based analysis of mammalian cell culture Parameters
The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Abstract
Within the framework of process analytical technology, infrared spectroscopy (IR) has been used for characterization of biopharmaceutical production processes. Although noninvasive attenuated total reflection (ATR) spectroscopy can be regarded as gold standard within IR‐based process analytics, simpler and more cost‐effective mid‐infrared (MIR) instruments might improve acceptability of this technique for high‐level monitoring of small scale experiments as well as for academia where financial restraints impede the use of costly equipment. A simple and straightforward at‐line mid‐IR instrument was used to monitor cell viability parameters, activity of lactate dehydrogenase (LDH), amount of secreted antibody, and concentration of glutamate and lactate in a Chinese hamster ovary cell culture process, applying multivariate prediction models, including only 25–28 calibration samples per model. Glutamate amount could be predicted with high accuracy (R 2 0.91 for independent test‐set) while antibody concentration achieved good prediction for concentrations >0.4 mg L−1. Prediction of LDH activity was accurate except for the low activity regime. The model for lactate monitoring was only moderately good and requires improvements. Relative cell viability between 20 and 95% could be predicted with low error (8.82%) in comparison to reference methods. An initial model for determining the number of nonviable cells displayed only acceptable accuracy and requires further improvement. In contrast, monitoring of viable cell number showed better accuracy than previously published ATR‐based results. These results prove the principal suitability of less sophisticated MIR instruments to monitor multiple parameters in biopharmaceutical production with relatively low investments and rather fast calibration procedures. © 2015 American Institute of Chemical Engineers Biotechnol. Prog., 31:578–584, 2015
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Fourier Transform Infrared Spectrometry
Griffiths, P. R., & de Haseth, J. A. (2007) · doi:10.1002/047010631x · Cited by 3,052
The multivariate calibration problem in chemistry solved by the PLS method
Wold, S., Martens, H., & Wold, H. (1983) · Lecture notes in mathematics · doi:10.1007/bfb0062108 · Cited by 1,185
On-line infrared spectroscopy for bioprocess monitoring
Landgrebe, D., Haake, C., Höpfner, T., Beutel, S., Hitzmann, B., Scheper, T., Rhiel, M., & Reardon, K. F. (2010) · Applied Microbiology and Biotechnology · doi:10.1007/s00253-010-2743-8 · Cited by 134 · cited 1×
“Compared to NIR, MIR has a better resolution and enables quantification of components at significantly lower concentration.(17) Additionally, as MIR relies on fundamental vibrations rather than combinations of overtones in a spectrum, it allows better discrimination in between different substances and more straight-fo…”
Cited by
Wasalathanthri, D. P., Rehmann, M. S., Song, Y., Gu, Y., Mi, L., Shao, C., Chemmalil, L., Lee, J., Ghose, S., Borys, M. C., et al. (2020) · Biotechnology and Bioengineering · doi:10.1002/bit.27461 · Cited by 177
Modern Sensor Tools and Techniques for Monitoring, Controlling, and Improving Cell Culture Processes
Reyes, S. J., Durocher, Y., Pham, P. L., & Henry, O. (2022) · Processes · doi:10.3390/pr10020189 · Cited by 130
Generic Raman‐based calibration models enabling real‐time monitoring of cell culture bioreactors
Mehdizadeh, H., Lauri, D., Karry, K. M., Moshgbar, M., Procopio‐Melino, R., & Drapeau, D. (2015) · Biotechnology Progress · doi:10.1002/btpr.2079 · Cited by 108
On-line soft sensing in upstream bioprocessing
Randek, J., & Mandenius, C.-F. (2018) · Critical Reviews in Biotechnology · doi:10.1080/07388551.2017.1312271 · Cited by 86
Yilmaz, D., Mehdizadeh, H., Navarro, D., Shehzad, A., O'Connor, M., & McCormick, P. (2020) · Biotechnology Progress · doi:10.1002/btpr.2947 · Cited by 51
Sensors and Techniques for On-Line Determination of Cell Viability in Bioprocess Monitoring
Rösner, L., Walter, F., Ude, C., John, G., & Beutel, S. (2022) · Bioengineering · doi:10.3390/bioengineering9120762 · Cited by 42
“If less accurate measurement results are acceptable, MIR is also suitable for determining viability in bioprocesses [86].”
BackgroundRaman spectroscopy as a method to replace off‐line pH during mammalian cell culture processes
Rafferty, C., O'Mahony, J., Burgoyne, B., Rea, R., Balss, K. M., & Latshaw, D. C. (2020) · Biotechnology and Bioengineering · doi:10.1002/bit.27197 · Cited by 31
Rafferty, C., O’Mahony, J., Rea, R., Burgoyne, B., Balss, K. M., Lyngberg, O., O’Mahony-Hartnett, C., Hill, D., & Schaefer, E. (2020) · Bioprocess and Biosystems Engineering · doi:10.1007/s00449-020-02336-2 · Cited by 21
Metadata
- Authors
- Capito, F., Zimmer, A., & Skudas, R.
- Venue
- Biotechnology Progress
- Publisher
- Wiley
- Published
- 2015-01-19
- Volume
- 31
- Issue
- 2
- Pages
- 578-584
- ISSN
- 1520-6033 (ISSN-L)
- 8756-7938
- OpenAlex
- W2167213373
- Cited by
- 25
- References
- 3
- FWCI
- 2.03
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.