CoChat

On-line soft sensing in upstream bioprocessing

Open access
Randek, Judit, Mandenius, Carl-Fredrik · 2018 · Critical Reviews in Biotechnology

The DOI matches its Crossref record; 150 of the 150 references it cites were found in a registry or an index.

Abstract

This review provides an overview and a critical discussion of novel possibilities of applying soft sensors for on-line monitoring and control of industrial bioprocesses. Focus is on bio-product formation in the upstream process but also the integration with other parts of the process is addressed. The term soft sensor is used for the combination of analytical hardware data (from sensors, analytical devices, instruments and actuators) with mathematical models that create new real-time information about the process. In particular, the review assesses these possibilities from an industrial perspective, including sensor performance, information value and production economy. The capabilities of existing analytical on-line techniques are scrutinized in view of their usefulness in soft sensor setups and in relation to typical needs in bioprocessing in general. The review concludes with specific recommendations for further development of soft sensors for the monitoring and control of upstream bioprocessing.

Overview

Integrity signals

Registry

Crossref · 10.1080/07388551.2017.1312271

Cites

150 of 150 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Verification

Claims the paper makes

We couldn’t retrieve this paper’s full text, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Citations

Cites

Show all 150 references

Research works printed but not linked: 6

  1. Federal Drug and Food Administration (FDA), 2004, Guidance for Industry: PAT—a framework for innovative pharmaceutical development, manufacturing, and quality assurance
  2. Sonnleitner B, 1999, Adv Biochem Eng Biotechnol, 66, 1
  3. Sonnleitner B, 2013, Adv Biochem Eng Biotechnol, 132, 1
  4. Chen JY, 2003, Biophys J, 84, 156A
  5. Fernandes RL, 2012, Adv Biochem Eng Biotechnol, 132, 137
  6. Glassey J, 2012, Adv Biochem Eng Biotechnol, 132, 167

Cited by

See all 91

Metadata

Authors
Randek, J., & Mandenius, C.-F.
Affiliations
Linköping University (SE)
Corresponding author
Mandenius, Carl-Fredrik
Venue
Critical Reviews in Biotechnology
Published
2017-04-20
Volume
38
Issue
1
Pages
106-121
ISSN
  • 0738-8551 (ISSN-L)
  • 1549-7801
OpenAlex
W2607276443
Cited by
86
References
149
Citations by year
2026: 9 · 2025: 12 · 2024: 11 · 2023: 9 · 2022: 9 · 2021: 12 · 2020: 12 · 2019: 6 · 2018: 3 · 2017: 3
FWCI
1.08
Type
journal article
Language
en
Open access
Licence
other-oa
Locations
  • Critical Reviews in Biotechnology (publishedVersion)
  • PubMed (publishedVersion)
  • Zenodo (CERN European Organization for Nuclear Research) (submittedVersion, other-oa)
Funders
  • EU-Horizon 2020 Marie Sklodowska-Curie Innovative Training Network BIORAPID (643056)
  • Linköping University
  • Cordis (MSC 643056)
Topics
  • Physical Sciences › Engineering › Control and Systems Engineering › Fault Detection and Control Systems
  • Physical Sciences › Engineering › Control and Systems Engineering › Control Systems and Identification
  • Physical Sciences › Chemistry › Analytical Chemistry › Spectroscopy and Chemometric Analyses
Keywords
soft sensors, real-time process monitoring, bioprocess control, upstream bioprocessing, process analytical technology, sensor performance, process integration, production economics
MeSH terms
Biotechnology, Models, Theoretical, Biosensing Techniques, Bioreactors

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: On-line soft sensing in upstream bioprocessing. https://app.cochat.ai/papers/10.1080/07388551.2017.1312271
The paper
Randek, J., & Mandenius, C.-F. (2018). On-line soft sensing in upstream bioprocessing. Critical Reviews in Biotechnology. https://doi.org/10.1080/07388551.2017.1312271

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.