Monitoring mAb cultivations with in‐situ raman spectroscopy: The influence of spectral selectivity on calibration models and industrial use as reliable PAT tool
The DOI matches its Crossref record; 8 of the 8 references it cites were found in a registry or an index.
Abstract
Raman spectroscopy is a suitable monitoring technique for CHO cultivations. However, a thorough discussion of peaks, bands, and region assignments to key metabolites and culture attributes, and the interpretability of produced calibrations is scarce. That understanding is vital for the long‐term predictive ability of monitoring models, and to facilitate lifecycle management that comply with regulatory guidelines. Several fed‐batch lab‐scale mAb mammalian cultivations were carried out, with in situ Raman spectroscopy used for process state estimation and attribute monitoring. The goal was to evaluate its use as a process analytical technology (PAT) tool to detect residual glucose and lactate levels, understand their dynamics and interconversion, and eventually estimate key performance culture and product quality attributes. Glucose and lactate models were optimized up to 0.31 g L −1 with 3 Latent Variables (LVs) and 0.19 g L −1 (2 LVs) accuracy, respectively. Glutamine and product titer models, were not specific and accurate enough, even though indirect calibrations were obtained with a RMSEP of 0.12 g L −1 (4 LVs) and 0.29 g L −1 (5 LVs), respectively. A critical discussion and details about the extensive work done in calibration development and optimization are provided. Namely, considering a risk‐based selection of variability sources impacting sample spectra, executing designed experiments with spiked cultivations, and using advanced chemometric procedures for variable selection and model cross validation. A strategy is presented to evaluation Raman spectroscopy as a reliable PAT technology fit‐for industrial use. © 2018 American Institute of Chemical Engineers Biotechnol. Prog. , 34:659–670, 2018
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Abu‐Absi, N. R., Kenty, B. M., Cuellar, M. E., Borys, M. C., Sakhamuri, S., Strachan, D. J., Hausladen, M. C., & Li, Z. J. (2011) · Biotechnology and Bioengineering · doi:10.1002/bit.23023 · Cited by 322 · cited 1×
“In this study, in situ Raman spectroscopy allowed the simultaneous prediction of culture parameters including glutamine, glutamate, glucose, lactate, ammonium, viable cell density (VCD), and total cell density (TCD).(15) Since then, many other authors have been developing predictive models for culture parameters and h…”
BackgroundRogers, R. S., Nightlinger, N. S., Livingston, B., Campbell, P., Bailey, R., & Balland, A. (2015) · mAbs · doi:10.1080/19420862.2015.1069454 · Cited by 231
Whelan, J., Craven, S., & Glennon, B. (2012) · Biotechnology Progress · doi:10.1002/btpr.1590 · Cited by 159 · cited 1×
“proved that calibration models for these parameters can be transferable from 3-L to the 15-L scale.(16) Another study(17) showed the feasibility of using Raman for predicting product yield from the early seed stages of the manufacturing process to the final large-scale bioreactor, and a key aspect of this work was the…”
MethodBerry, B., Moretto, J., Matthews, T., Smelko, J., & Wiltberger, K. (2015) · Biotechnology Progress · doi:10.1002/btpr.2035 · Cited by 142 · cited 1×
“However, again there was no clear assignment of each metabolite to specific spectral variables and the authors concluded that improvement of model predictive capabilities must come from better Raman spectral region assignments and component spiking studies.(18) In fact, recent studies showed that spiked samples can he…”
BackgroundGeneric Raman‐based calibration models enabling real‐time monitoring of cell culture bioreactors
Mehdizadeh, H., Lauri, D., Karry, K. M., Moshgbar, M., Procopio‐Melino, R., & Drapeau, D. (2015) · Biotechnology Progress · doi:10.1002/btpr.2079 · Cited by 108
Shaw, A. D., Kaderbhai, N., Jones, A., Woodward, A. M., Goodacre, R., Rowland, J. J., & Kell, D. B. (1999) · Applied Spectroscopy · doi:10.1366/0003702991945777 · Cited by 84
Advances in process monitoring tools for cell culture bioprocesses
Zhao, L., Fu, H., Zhou, W., & Hu, W. (2015) · Engineering in Life Sciences · doi:10.1002/elsc.201500006 · Cited by 81
On‐line monitoring of Phaffia rhodozyma fed‐batch process with in situ dispersive raman spectroscopy
Cannizzaro, C., Rhiel, M., Marison, I., & von Stockar, U. (2003) · Biotechnology and Bioengineering · doi:10.1002/bit.10698 · Cited by 70
Cited by
Wasalathanthri, D. P., Rehmann, M. S., Song, Y., Gu, Y., Mi, L., Shao, C., Chemmalil, L., Lee, J., Ghose, S., Borys, M. C., et al. (2020) · Biotechnology and Bioengineering · doi:10.1002/bit.27461 · Cited by 177
The role of Raman spectroscopy in biopharmaceuticals from development to manufacturing
Esmonde-White, K. A., Cuellar, M., & Lewis, I. R. (2022) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-021-03727-4 · Cited by 152
“[53], was to find a direct correlation of metabolite concentration with Raman bands through sample spiking of glucose, lactate, or glutamate.”
BackgroundModern Sensor Tools and Techniques for Monitoring, Controlling, and Improving Cell Culture Processes
Reyes, S. J., Durocher, Y., Pham, P. L., & Henry, O. (2022) · Processes · doi:10.3390/pr10020189 · Cited by 130
Tulsyan, A., Schorner, G., Khodabandehlou, H., Wang, T., Coufal, M., & Undey, C. (2019) · Biotechnology and Bioengineering · doi:10.1002/bit.27100 · Cited by 82
Tulsyan, A., Wang, T., Schorner, G., Khodabandehlou, H., Coufal, M., & Undey, C. (2020) · Biotechnology and Bioengineering · doi:10.1002/bit.27205 · Cited by 57
Helgers, H., Schmidt, A., Lohmann, L. J., Vetter, F. L., Juckers, A., Jensch, C., Mouellef, M., Zobel-Roos, S., & Strube, J. (2021) · Processes · doi:10.3390/pr9010172 · Cited by 52
Feidl, F., Garbellini, S., Luna, M. F., Vogg, S., Souquet, J., Broly, H., Morbidelli, M., & Butté, A. (2019) · Processes · doi:10.3390/pr7100683 · Cited by 46
Pais, D. A. M., Portela, R. M. C., Carrondo, M. J. T., Isidro, I. A., & Alves, P. M. (2019) · Biotechnology and Bioengineering · doi:10.1002/bit.27117 · Cited by 36
Santos, R. M., Kaiser, P., Menezes, J. C., & Peinado, A. (2019) · Talanta · doi:10.1016/j.talanta.2019.02.088 · Cited by 33
Self-citationPais, D. A. M., Galrão, P. R. S., Kryzhanska, A., Barbau, J., Isidro, I. A., & Alves, P. M. (2020) · Processes · doi:10.3390/pr8040487 · Cited by 25
Metadata
- Authors
- Santos, R. M., Kessler, J., Salou, P., Menezes, J. C., & Peinado, A.
- Venue
- Biotechnology Progress
- Publisher
- Wiley
- Published
- 2018-04-17
- Volume
- 34
- Issue
- 3
- Pages
- 659-670
- ISSN
- 1520-6033 (ISSN-L)
- 8756-7938
- OpenAlex
- W2795212258
- Cited by
- 82
- References
- 8
- FWCI
- 3.75
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.