In situ near infrared spectroscopy for analyte‐specific monitoring of glucose and ammonium in streptomyces coelicolor fermentations
The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Abstract
There are many challenges associated with in situ collection of near infrared (NIR) spectra in a fermentation broth, particularly for highly aerated and agitated fermentations with filamentous organisms. In this study, antibiotic fermentation by the filamentous bacterium Streptomyces coelicolor was used as a model process. Partial least squares (PLS) regression models were calibrated for glucose and ammonium based on NIR spectra collected in situ. To ensure that the models were calibrated based on analyte‐specific information, semisynthetic samples were used for model calibration in addition to data from standard batches. Thereby, part of the inherent correlation between the analytes could be eliminated. The set of semisynthetic samples were generated from fermentation broth from five separate fermentations to which different amounts of glucose, ammonium, and biomass were added. This method has previously been used off line but never before in situ. The use of semisynthetic samples along with validation on an independent batch provided a critical and realistic evaluation of analyte‐specific models based on in situ NIR spectroscopy. The prediction of glucose was highly satisfactory resulting in a RMSEP of 1.1 g/L. The prediction of ammonium based on NIR spectra collected in situ was not satisfactory. A comparison with models calibrated based on NIR spectra collected off line suggested that this is caused by signal attenuation in the optical fibers in the region above 2,000 nm; a region which contains important absorption bands for ammonium. For improved predictions of ammonium in situ, it is suggested to focus efforts on enhancing the signal in that particular region. © 2009 American Institute of Chemical Engineers Biotechnol. Prog., 2010
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Progress in monitoring, modeling and control of bioprocesses during the last 20 years
Schügerl, K. (2001) · Journal of Biotechnology · doi:10.1016/s0168-1656(00)00361-8 · Cited by 278
Near Infrared Spectroscopy for Bioprocess Monitoring and Control: Current Status and Future Trends
Scarff, M., Arnold, S. A., Harvey, L. M., & McNeil, B. (2006) · Critical Reviews in Biotechnology · doi:10.1080/07388550500513677 · Cited by 124
Cited by
Claßen, J., Aupert, F., Reardon, K. F., Solle, D., & Scheper, T. (2017) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-016-0068-x · Cited by 176
On-line infrared spectroscopy for bioprocess monitoring
Landgrebe, D., Haake, C., Höpfner, T., Beutel, S., Hitzmann, B., Scheper, T., Rhiel, M., & Reardon, K. F. (2010) · Applied Microbiology and Biotechnology · doi:10.1007/s00253-010-2743-8 · Cited by 134
“Table 1 (continued) Microorganism/cell line Analyte Method Source S. cerevisiae Cell density NIR Ge et al. (1994) S. cerevisiae Biomass NIR Kiviharju et al. (2007) S. cerevisiae Glucose MIR Mazarevica et al. (2004) Ethanol S. cerevisiae 1-Phenyl-1,2-propandion MIR Trevisan and Poppi (2008) ®-1-Hydroxy-1-phenyl-2-propa…”
BackgroundMethodInfluentialOn-line soft sensing in upstream bioprocessing
Randek, J., & Mandenius, C.-F. (2018) · Critical Reviews in Biotechnology · doi:10.1080/07388551.2017.1312271 · Cited by 86
Metadata
- Authors
- Petersen, N., Ödman, P., Padrell, A. E. C., Stocks, S., Lantz, A. E., & Gernaey, K. V.
- Venue
- Biotechnology Progress
- Publisher
- Wiley
- Published
- 2009-11-06
- Volume
- 26
- Issue
- 1
- Pages
- 263-271
- ISSN
- 1520-6033 (ISSN-L)
- 8756-7938
- OpenAlex
- W2091677719
- Cited by
- 48
- References
- 2
- FWCI
- 3.40
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.