The DOI matches its Crossref record.
Synthetic DNA Aptamers to Detect Protein Molecular Variants in a High‐Throughput Fluorescence Quenching Assay
Abstract
Real‐time protein detection in homogeneous solutions is necessary in many biotechnology and biomedical studies. The recent development of molecular aptamers, combined with fluorescence techniques, may provide an easy and efficient approach to protein elucidation. This report describes the development of a fluorescence‐based assay with synthetic DNA aptamers that can detect and distinguish molecular variants of proteins in biological samples in a high‐throughput process. We used an aptamer with high affinity for the B chain of platelet‐derived growth factor (PDGF), labeled it with a fluorophore and a quencher at the two termini, and measured fluorescence quenching by PDGF. The specific quenching can be used to detect PDGF at picomolar concentrations even in the presence of serum and other cell‐derived proteins in cell culture media. This is the first successful application of a synthetic aptamer for the detection of tumor‐related proteins directly from the tumor cells. We also show that three highly related molecular variants of PDGF (AA, AB, and BB dimers) can be distinguished from one another in this single‐step assay, which can be readily adapted to a microtiter plate assay for high‐throughput analysis. The use of fluorescence quenching as a measure of binding between the DNA probe and the target protein eliminates potential false signals that may arise in traditional fluorescence enhancement assays as a result of degradation of the DNA aptamer by contaminating nucleases in biological specimens. This assay is applicable to proteins that are not naturally DNA binding. The excellent specificity, ultrahigh sensitivity, and simplicity of this one‐step assay addresses a growing need for high‐throughput methods that detect changes in the expression of gene products and their variants in cell cultures and biological specimens.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Aptamers evolved from live cells as effective molecular probes for cancer study
Shangguan, D., Li, Y., Tang, Z., Cao, Z. C., Chen, H. W., Mallikaratchy, P., Sefah, K., Yang, C. J., & Tan, W. (2006) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0602615103 · Cited by 1,516
Self-citationLabel‐Free Electronic Detection of Thrombin in Blood Serum by Using an Aptamer‐Based Sensor
Xiao, Y., Lubin, A. A., Heeger, A. J., & Plaxco, K. W. (2005) · Angewandte Chemie International Edition · doi:10.1002/anie.200500989 · Cited by 812
Applications of Aptamers as Sensors
Cho, E. J., Lee, J.-W., & Ellington, A. D. (2009) · Annual Review of Analytical Chemistry · doi:10.1146/annurev.anchem.1.031207.112851 · Cited by 788
Aptamer-Based Detection of Circulating Targets for Precision Medicine
Wu, L., Wang, Y., Xu, X., Liu, Y., Lin, B., Zhang, M., Zhang, J., Wan, S., Yang, C., & Tan, W. (2021) · Chemical Reviews · doi:10.1021/acs.chemrev.0c01140 · Cited by 705
Self-citationZhao, W., Ali, M. M., Brook, M. A., & Li, Y. (2008) · Angewandte Chemie International Edition · doi:10.1002/anie.200705982 · Cited by 587
Aptamers: molecular tools for analytical applications
Mairal, T., Cengiz Özalp, V., Lozano Sánchez, P., Mir, M., Katakis, I., & O’Sullivan, C. K. (2008) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-007-1346-4 · Cited by 587
Huang, C.-C., Huang, Y.-F., Cao, Z., Tan, W., & Chang, H.-T. (2005) · Analytical Chemistry · doi:10.1021/ac050957q · Cited by 542
Self-citationAptamer/AuNP Biosensor for Colorimetric Profiling of Exosomal Proteins
Jiang, Y., Shi, M., Liu, Y., Wan, S., Cui, C., Zhang, L., & Tan, W. (2017) · Angewandte Chemie International Edition · doi:10.1002/anie.201703807 · Cited by 487
Self-citationTan, W., Wang, K., & Drake, T. J. (2004) · Current Opinion in Chemical Biology · doi:10.1016/j.cbpa.2004.08.010 · Cited by 461
Self-citationIn Vitro Selection of Structure‐Switching Signaling Aptamers
Nutiu, R., & Li, Y. (2005) · Angewandte Chemie International Edition · doi:10.1002/anie.200461848 · Cited by 455
DNA-Mediated Homogeneous Binding Assays for Nucleic Acids and Proteins
Zhang, H., Li, F., Dever, B., Li, X.-F., & Le, X. C. (2013) · Chemical Reviews · doi:10.1021/cr300340p · Cited by 415
Aptamer−Nanoparticle Strip Biosensor for Sensitive Detection of Cancer Cells
Liu, G., Mao, X., Phillips, J. A., Xu, H., Tan, W., & Zeng, L. (2009) · Analytical Chemistry · doi:10.1021/ac901889s · Cited by 340
Self-citationLight-switching excimer probes for rapid protein monitoring in complex biological fluids
Yang, C. J., Jockusch, S., Vicens, M., Turro, N. J., & Tan, W. (2005) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0508821102 · Cited by 337
Self-citationBioanalytical Chemistry of Cytokines–a Review
Stenken, J. A., & Poschenrieder, A. J. (2015) · Analytica Chimica Acta · doi:10.1016/j.aca.2014.10.009 · Cited by 302
Nucleic acid-based fluorescent probes and their analytical potential
Juskowiak, B. (2011) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-010-4304-5 · Cited by 252
Metadata
- Authors
- Fang, X., Sen, A., Vicens, M., & Tan, W.
- Venue
- ChemBioChem
- Publisher
- Wiley
- Published
- 2003-09-04
- Volume
- 4
- Issue
- 9
- Pages
- 829-834
- ISSN
- 1439-4227 (ISSN-L)
- 1439-7633
- OpenAlex
- W2037200280
- Cited by
- 168
- References
- 0
- FWCI
- 3.75
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.