The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Light-switching excimer probes for rapid protein monitoring in complex biological fluids
Open accessAbstract
Quantitative protein bioanalysis in complex biological fluids presents considerable challenges in biological studies and disease diagnosis. The major obstacles are the background signals from both the probe and the biological fluids where the proteins reside. We have molecularly engineered light-switching excimer aptamer probes for rapid and sensitive detection of a biomarker protein, platelet-derived growth factor (PDGF). Labeled with one pyrene at each end, the aptamer switches its fluorescence emission from ≈400 nm (pyrene monomer) to 485 nm (pyrene excimer) upon PDGF binding. This fluorescence wavelength change from monomer to excimer emission is a result of aptamer conformation rearrangement induced by target binding. The excimer probe is able to effectively detect picomolar PDGF in homogeneous solutions. Because the excimer has a much longer fluorescence lifetime (≈40 ns) than that of the background (≈5 ns), time-resolved measurements were used to eliminate the biological background. We thus were able to detect PDGF in a cell sample quantitatively without any sample pretreatment. This molecular engineering strategy can be used to develop other aptamer probes for protein monitoring. Combined with lifetime-based measurements and molecular engineering, light-switching excimer aptamer probes hold great potential in protein analysis for biomedical studies.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Mfold web server for nucleic acid folding and hybridization prediction
Zuker, M. (2003) · Nucleic Acids Research · doi:10.1093/nar/gkg595 · Cited by 13,404
Cited by
Aptamers evolved from live cells as effective molecular probes for cancer study
Shangguan, D., Li, Y., Tang, Z., Cao, Z. C., Chen, H. W., Mallikaratchy, P., Sefah, K., Yang, C. J., & Tan, W. (2006) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0602615103 · Cited by 1,516
Self-citationUsing personal glucose meters and functional DNA sensors to quantify a variety of analytical targets
Xiang, Y., & Lu, Y. (2011) · Nature Chemistry · doi:10.1038/nchem.1092 · Cited by 677
Aptamer−Nanoparticle Strip Biosensor for Sensitive Detection of Cancer Cells
Liu, G., Mao, X., Phillips, J. A., Xu, H., Tan, W., & Zeng, L. (2009) · Analytical Chemistry · doi:10.1021/ac901889s · Cited by 340
Self-citationSacui, I., Hsieh, W.-C., Manna, A., Sahu, B., & Ly, D. H. (2015) · Journal of the American Chemical Society · doi:10.1021/jacs.5b04566 · Cited by 69
Metadata
- Authors
- Yang, C. J., Jockusch, S., Vicens, M., Turro, N. J., & Tan, W.
- Venue
- Proceedings of the National Academy of Sciences
- Published
- 2005-11-21
- Volume
- 102
- Issue
- 48
- Pages
- 17278-17283
- ISSN
- 0027-8424 (ISSN-L)
- 1091-6490
- OpenAlex
- W2165116615
- Cited by
- 337
- References
- 1
- FWCI
- 6.22
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Light-switching excimer probes for rapid protein monitoring in complex biological fluids. https://app.cochat.ai/papers/10.1073/pnas.0508821102
- The paper
- Yang, C. J., Jockusch, S., Vicens, M., Turro, N. J., & Tan, W. (2005). Light-switching excimer probes for rapid protein monitoring in complex biological fluids. Proceedings of the National Academy of Sciences. https://doi.org/10.1073/pnas.0508821102
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.