The DOI matches its Crossref record; 32 of the 32 references it cites were found in a registry or an index.
Risk for radiation‐induced cataract for staff in interventional cardiology: Is there reason for concern?
Abstract
Objectives: To examine the prevalence of radiation‐associated lens opacities among interventional cardiologists and nurses and correlate with occupational radiation exposure. Background: Interventional cardiology personnel are exposed to relatively high levels of X‐rays and based on recent findings of radiation‐associated lens opacities in other cohorts, they may be at risk for cataract without use of ocular radiation protection. Methods: Eyes of interventional cardiologists, nurses, and age‐ and sex‐matched unexposed controls were screened by dilated slit lamp examination and posterior lens changes graded using a modified Merriam‐Focht technique. Individual cumulative lens X‐ray exposure was calculated from responses to a questionnaire and personal interview. Results: The prevalence of radiation‐associated posterior lens opacities was 52% (29/56, 95% CI: 35–73) for interventional cardiologists, 45% (5/11, 95% CI: 15–100) for nurses, and 9% (2/22, 95% CI: 1–33) for controls. Relative risks of lens opacity was 5.7 (95% CI: 1.5–22) for interventional cardiologists and 5.0 (95% CI: 1.2–21) for nurses. Estimated cumulative ocular doses ranged from 0.01 to 43 Gy with mean and median values of 3.4 and 1.0 Gy, respectively. A strong dose–response relationship was found between occupational exposure and the prevalence of radiation‐associated posterior lens changes. Conclusions: These findings demonstrate a dose dependent increased risk of posterior lens opacities for interventional cardiologists and nurses when radiation protection tools are not used. While study of a larger cohort is needed to confirm these findings, the results suggest ocular radio‐protection should be utilized. © 2010 Wiley‐Liss, Inc.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Benefits and costs, an eternal balance
Dixon, A. K. (2007) · Annals of the ICRP · doi:10.1016/j.icrp.2007.09.001 · Cited by 1,355
Statistics Notes: The odds ratio
Bland, J. M. (2000) · BMJ · doi:10.1136/bmj.320.7247.1468 · Cited by 1,294
International Atomic Energy Agency (IAEA)
(2018) · Yearbook of International Cooperation on Environment and Development 1998–99 · doi:10.4324/9781315066547-57 · Cited by 1,173
Duane's Clinical Ophthalmology
Duane, T. D., & Tasman, W. S. (1993) · Medical Entomology and Zoology · Cited by 1,014
Valentin, J. (2000) · Annals of the ICRP · doi:10.1016/s0146-6453(01)00004-5 · Cited by 964
Radiation Protection in Medicine
(2007) · Annals of the ICRP · doi:10.1016/j.icrp.2008.07.001 · Cited by 641
Prevalence of Cataract and Pseudophakia/Aphakia Among Adults in theUnited States
(2004) · Archives of Ophthalmology · doi:10.1001/archopht.122.4.487 · Cited by 577
Chodick, G., Bekiroglu, N., Hauptmann, M., Alexander, B. H., Freedman, D. M., Doody, M. M., Cheung, L. C., Simon, S. L., Weinstock, R. M., Bouville, A., et al. (2008) · American Journal of Epidemiology · doi:10.1093/aje/kwn171 · Cited by 407
Space Radiation and Cataracts in Astronauts
Cucinotta, F. A., Manuel, F. K., Jones, J., Iszard, G., Murrey, J., Djojonegro, B., & Wear, M. (2001) · Radiation Research · doi:10.1667/0033-7587(2001)156[0460:sracia]2.0.co;2 · Cited by 391
Radiation Cataractogenesis: A Review of Recent Studies
Ainsbury, E. A., Bouffler, S. D., Dörr, W., Graw, J., Muirhead, C. R., Edwards, A. A., & Cooper, J. (2009) · Radiation Research · doi:10.1667/rr1688.1 · Cited by 374
Cited by
Stewart, F. A., Akleyev, A. V., Hauer-Jensen, M., Hendry, J. H., Kleiman, N. J., MacVittie, T. J., Aleman, B. M., Edgar, A. B., Mabuchi, K., Muirhead, C. R., et al. (2012) · Annals of the ICRP · doi:10.1016/j.icrp.2012.02.001 · Cited by 1,604
Self-citationICRP Publication 120: Radiological Protection in Cardiology
Cousins, C., Miller, D. L., Bernardi, G., Rehani, M. M., Schofield, P., Vañó, E., Einstein, A. J., Geiger, B., Heintz, P., Padovani, R., et al. (2013) · Annals of the ICRP · doi:10.1016/j.icrp.2012.09.001 · Cited by 428
Self-citationRehani, M. M., Ciraj-Bjelac, O., Vañó, E., Miller, D. L., Walsh, S., Giordano, B. D., & Persliden, J. (2010) · Annals of the ICRP · doi:10.1016/j.icrp.2012.03.001 · Cited by 344
Self-citationHeidbuchel, H., Wittkampf, F. H. M., Vano, E., Ernst, S., Schilling, R., Picano, E., Mont, L., ESC Scientific Document Group, Jais, P., de Bono, J., et al. (2014) · EP Europace · doi:10.1093/europace/eut409 · Cited by 311
Self-citationKry, S. F., Bednarz, B., Howell, R. M., Dauer, L., Followill, D., Klein, E., Paganetti, H., Wang, B., Wuu, C., & George Xu, X. (2017) · Medical Physics · doi:10.1002/mp.12462 · Cited by 307
Radiation safety program for the cardiac catheterization laboratory
E. Chambers, C., A. Fetterly, K., Holzer, R., Paul Lin, P., C. Blankenship, J., Balter, S., & K. Laskey, W. (2011) · Catheterization and Cardiovascular Interventions · doi:10.1002/ccd.22867 · Cited by 301
ICRP Publication 139: Occupational Radiological Protection in Interventional Procedures
López, P. O., Dauer, L. T., Loose, R., Martin, C. J., Miller, D. L., Vañó, E., Doruff, M., Padovani, R., Massera, G., & Yoder, C. (2018) · Annals of the ICRP · doi:10.1177/0146645317750356 · Cited by 276
Vano, E., Kleiman, N. J., Duran, A., Romano-Miller, M., & Rehani, M. M. (2013) · Journal of Vascular and Interventional Radiology · doi:10.1016/j.jvir.2012.10.016 · Cited by 268
Self-citationKamat, A. M., Flaig, T. W., Grossman, H. B., Konety, B., Lamm, D., O'Donnell, M. A., Uchio, E., Efstathiou, J. A., & Taylor, J. A. (2015) · Nature Reviews Urology · doi:10.1038/nrurol.2015.58 · Cited by 252
Metadata
- Authors
- Ciraj‐Bjelac, O., Rehani, M. M., Sim, K. H., Liew, H. B., Vano, E., & Kleiman, N. J.
- Venue
- Catheterization and Cardiovascular Interventions
- Publisher
- Wiley
- Published
- 2010-11-15
- Volume
- 76
- Issue
- 6
- Pages
- 826-834
- ISSN
- 1522-1946 (ISSN-L)
- 1522-726X
- OpenAlex
- W2114719365
- Cited by
- 330
- References
- 32
- FWCI
- 16.15
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.