Sugar–Poly(para‐phenylene ethynylene) Conjugates as Sensory Materials: Efficient Quenching by Hg2+ and Pb2+ Ions
The DOI matches its Crossref record; 27 of the 27 references it cites were found in a registry or an index.
Abstract
Three polar poly(para‐phenylene ethynylene)s (PPE) were synthesized by utilizing the Heck–Sonogashira protocol. Two of the PPEs carry β‐glucopyranose substituents. Depending upon the linker used between the glycol units and the backbone, the fluorescence of these PPEs can be quenched by Hg 2+ and Pb 2+ to a varying degree. Monomeric model compounds that are substituted with only one glucose unit are not efficiently quenched. The presence of many glucose substituents in one PPE assembly led to a large increase in the binding constant to Hg 2+ and quenching of the fluorescence was amplified.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Principles of Fluorescence Spectroscopy
Lakowicz, J. R. (1999) · Springer eBooks · doi:10.1007/978-1-4757-3061-6 · Cited by 26,947
(1978) · Cited by 4,918
Mammen, M., Choi, S.-K., & Whitesides, G. M. (1998) · Angewandte Chemie International Edition · doi:10.1002/(sici)1521-3773(19981102)37:20<2754::aid-anie2754>3.0.co;2-3 · Cited by 4,110
Conjugated Polymer-Based Chemical Sensors
McQuade, D. T., Pullen, A. E., & Swager, T. M. (2000) · Chemical Reviews · doi:10.1021/cr9801014 · Cited by 3,718
Poly(aryleneethynylene)s: Syntheses, Properties, Structures, and Applications
Bunz, U. H. F. (2000) · Chemical Reviews · doi:10.1021/cr990257j · Cited by 1,661
Self-citationA Colorimetric Lead Biosensor Using DNAzyme-Directed Assembly of Gold Nanoparticles
Liu, J., & Lu, Y. (2003) · Journal of the American Chemical Society · doi:10.1021/ja034775u · Cited by 1,347
Fluorescent Porous Polymer Films as TNT Chemosensors: Electronic and Structural Effects
Yang, J.-S., & Swager, T. M. (1998) · Journal of the American Chemical Society · doi:10.1021/ja982293q · Cited by 1,188
Clarkson, T. W. (1997) · Critical Reviews in Clinical Laboratory Sciences · doi:10.3109/10408369708998098 · Cited by 886
Chen, L., McBranch, D. W., Wang, H.-L., Helgeson, R., Wudl, F., & Whitten, D. G. (1999) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.96.22.12287 · Cited by 857
A Highly Sensitive and Selective Catalytic DNA Biosensor for Lead Ions
Li, J., & Lu, Y. (2000) · Journal of the American Chemical Society · doi:10.1021/ja0021316 · Cited by 704
Zhou, Q., & Swager, T. M. (1995) · Journal of the American Chemical Society · doi:10.1021/ja00155a023 · Cited by 690
Principles of fluorescence spectroscopy
Ricchelli, F. (1989) · Journal of Photochemistry and Photobiology B: Biology · doi:10.1016/1011-1344(89)80070-3 · Cited by 621
DNA detection using water-soluble conjugated polymers and peptide nucleic acid probes
Gaylord, B. S., Heeger, A. J., & Bazan, G. C. (2002) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.162375999 · Cited by 605
Mammen, M., Choi, S.-K., & Whitesides, G. M. (1998) · Angewandte Chemie · doi:10.1002/(sici)1521-3757(19981016)110:20<2908::aid-ange2908>3.0.co;2-2 · Cited by 574
A Fluorescent Self‐Amplifying Wavelength‐Responsive Sensory Polymer for Fluoride Ions
Kim, T., & Swager, T. M. (2003) · Angewandte Chemie International Edition · doi:10.1002/anie.200352075 · Cited by 350
Chae, M. Y., & Czarnik, A. W. (1992) · Journal of the American Chemical Society · doi:10.1021/ja00050a085 · Cited by 327
A Selective, Ratiometric Fluorescent Sensor for Pb2+
Deo, S., & Godwin, H. A. (1999) · Journal of the American Chemical Society · doi:10.1021/ja992238x · Cited by 305
Lead, mercury, cadmium and arsenic in the environment
Benarie, M. (1988) · Science of The Total Environment · doi:10.1016/0048-9697(88)90384-1 · Cited by 269
Fluorescein Provides a Resonance Gate for FRET from Conjugated Polymers to DNA Intercalated Dyes
Wang, S., Gaylord, B. S., & Bazan, G. C. (2004) · Journal of the American Chemical Society · doi:10.1021/ja035550m · Cited by 260
Interpolyelectrolyte Complexes of Conjugated Copolymers and DNA: Platforms for Multicolor Biosensors
Liu, B., & Bazan, G. C. (2004) · Journal of the American Chemical Society · doi:10.1021/ja038667j · Cited by 250
Cellulose Solutions in Water Containing Metal Complexes
Saalwächter, K., Burchard, W., Klüfers, P., Kettenbach, G., Mayer, P., Klemm, D., & Dugarmaa, S. (2000) · Macromolecules · doi:10.1021/ma991893m · Cited by 160
New highly sensitive and selective catalytic DNA biosensors for metal ions
Lu, Y., Liu, J., Li, J., Bruesehoff, P. J., Pavot, C. M.-B., & Brown, A. K. (2003) · Biosensors and Bioelectronics · doi:10.1016/s0956-5663(03)00013-7 · Cited by 134
Mercury — Cadmium — Lead Handbook for Sustainable Heavy Metals Policy and Regulation
Scoullos, M. J., Vonkeman, G. H., Thornton, I., & Makuch, Z. (2001) · Environment & policy · doi:10.1007/978-94-010-0403-9 · Cited by 108
Detection of Single Nucleotide Mismatches via Fluorescent Polymer Superquenching
Kushon, S. A., Bradford, K., Marin, V. L., Suhrada, C. P., Armitage, B. A., McBranch, D. W., & Whitten, D. G. (2003) · Langmuir · doi:10.1021/la034323v · Cited by 79
Brockmann, T. W., & Tour, J. M. (1995) · Journal of the American Chemical Society · doi:10.1021/ja00121a001 · Cited by 74
A Fluorescent Self‐Amplifying Wavelength‐Responsive Sensory Polymer for Fluoride Ions
Kim, T., & Swager, T. M. (2003) · Angewandte Chemie · doi:10.1002/ange.200352075 · Cited by 62
A Transition Metal Complex of D-Glucose
Klüfers, P., & Kunte, T. (2001) · Angewandte Chemie International Edition · doi:10.1002/1521-3773(20011119)40:22<4210::aid-anie4210>3.0.co;2-z · Cited by 55
Cited by
Chemical Sensors Based on Amplifying Fluorescent Conjugated Polymers
Thomas, S. W., Joly, G. D., & Swager, T. M. (2007) · Chemical Reviews · doi:10.1021/cr0501339 · Cited by 4,198
Samuel, I. D. W., & Turnbull, G. A. (2007) · Chemical Reviews · doi:10.1021/cr050152i · Cited by 1,464
Acetylenic Polymers: Syntheses, Structures, and Functions
Liu, J., Lam, J. W. Y., & Tang, B. Z. (2009) · Chemical Reviews · doi:10.1021/cr900149d · Cited by 1,196
Phillips, R. L., Miranda, O. R., You, C., Rotello, V. M., & Bunz, U. H. F. (2008) · Angewandte Chemie International Edition · doi:10.1002/anie.200703369 · Cited by 402
Self-citationGold Nanoparticle–Fluorophore Complexes: Sensitive and Discerning “Noses” for Biosystems Sensing
Bunz, U. H. F., & Rotello, V. M. (2010) · Angewandte Chemie International Edition · doi:10.1002/anie.200906928 · Cited by 357
Self-citation
Metadata
- Authors
- Kim, I., Erdogan, B., Wilson, J. N., & Bunz, U. H. F.
- Venue
- Chemistry – A European Journal
- Publisher
- Wiley
- Published
- 2004-12
- Volume
- 10
- Issue
- 24
- Pages
- 6247-6254
- ISSN
- 0947-6539 (ISSN-L)
- 1521-3765
- OpenAlex
- W2131310924
- Cited by
- 197
- References
- 27
- FWCI
- 5.19
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.