The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Enzyme‐Free Amperometric Sensing of Glucose by Using Gold Nanoparticles
Abstract
A nonenzymatic electrochemical method is described for the detection of glucose by using gold (Au) nanoparticles self‐assembled on a three‐dimensional (3D) silicate network obtained by using sol–gel processes. The nanosized Au particles have been self‐assembled on the thiol tail groups of the silicate network and enlarged by hydroxylamine. The Au nanoparticles efficiently catalyze the oxidation of glucose at less‐positive potential (0.16 V) in phosphate buffer solution (pH 9.2) in the absence of any enzymes or redox mediators. The Au nanoparticle‐modified transducer (MPTS‐nAuE) was successfully used for the amperometric sensing of glucose and it showed excellent sensitivity with a detection limit of 50 n M. The common interfering agent ascorbate (AA) does not interfere with the detection of glucose. The MPTS‐nAuE transducer showed individual voltammetric responses for glucose and AA. This transducer responded linearly to glucose in the range of 0–8 m M and the sensitivity of the transducer was found to be 0.179 nA cm−2 n M−1. Excellent reproducibility, and long‐term storage and operational stability was observed for this transducer.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Fluorescence-based glucose sensors
Pickup, J. C., Hussain, F., Evans, N. D., Rolinski, O. J., & Birch, D. J. S. (2005) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2004.10.002 · Cited by 616
Enzyme-Based Biosensors for in Vivo Measurements
Wilson, G. S., & Hu, Y. (2000) · Chemical Reviews · doi:10.1021/cr990003y · Cited by 434
Cited by
Gold Nanoparticles in Chemical and Biological Sensing
Saha, K., Agasti, S. S., Kim, C., Li, X., & Rotello, V. M. (2012) · Chemical Reviews · doi:10.1021/cr2001178 · Cited by 4,620
Jiang, L.-C., & Zhang, W.-D. (2010) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2009.10.038 · Cited by 667
An improved sensitivity non-enzymatic glucose sensor based on a CuO nanowire modified Cu electrode
Zhuang, Z., Su, X., Yuan, H., Sun, Q., Xiao, D., & Choi, M. M. F. (2008) · The Analyst · doi:10.1039/b712970j · Cited by 481
Electrochemical Sensors for Clinic Analysis
Wang, Y., Xu, H., Zhang, J., & Li, G. (2008) · Sensors · doi:10.3390/s8042043 · Cited by 398
Advances in enzyme-free electrochemical sensors for hydrogen peroxide, glucose, and uric acid
Chen, X., Wu, G., Cai, Z., Oyama, M., & Chen, X. (2014) · Microchimica Acta · doi:10.1007/s00604-013-1098-0 · Cited by 366
Metadata
- Authors
- Jena, B. K., & Raj, C. R.
- Venue
- Chemistry – A European Journal
- Publisher
- Wiley
- Published
- 2006-03-10
- Volume
- 12
- Issue
- 10
- Pages
- 2702-2708
- ISSN
- 0947-6539 (ISSN-L)
- 1521-3765
- OpenAlex
- W2150827236
- Cited by
- 259
- References
- 2
- FWCI
- 15.86
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Enzyme‐Free Amperometric Sensing of Glucose by Using Gold Nanoparticles. https://app.cochat.ai/papers/10.1002/chem.200501051
- The paper
- Jena, B. K., & Raj, C. R. (2006). Enzyme‐Free Amperometric Sensing of Glucose by Using Gold Nanoparticles. Chemistry – A European Journal. https://doi.org/10.1002/chem.200501051
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.