The DOI matches its Crossref record; 43 of the 43 references it cites were found in a registry or an index.
Enzyme‐Free Amperometric Sensing of Glucose by Using Gold Nanoparticles
Abstract
A nonenzymatic electrochemical method is described for the detection of glucose by using gold (Au) nanoparticles self‐assembled on a three‐dimensional (3D) silicate network obtained by using sol–gel processes. The nanosized Au particles have been self‐assembled on the thiol tail groups of the silicate network and enlarged by hydroxylamine. The Au nanoparticles efficiently catalyze the oxidation of glucose at less‐positive potential (0.16 V) in phosphate buffer solution (pH 9.2) in the absence of any enzymes or redox mediators. The Au nanoparticle‐modified transducer (MPTS‐nAuE) was successfully used for the amperometric sensing of glucose and it showed excellent sensitivity with a detection limit of 50 n M. The common interfering agent ascorbate (AA) does not interfere with the detection of glucose. The MPTS‐nAuE transducer showed individual voltammetric responses for glucose and AA. This transducer responded linearly to glucose in the range of 0–8 m M and the sensitivity of the transducer was found to be 0.179 nA cm−2 n M−1. Excellent reproducibility, and long‐term storage and operational stability was observed for this transducer.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Cullity, B. D., & Weymouth, J. W. (1957) · American Journal of Physics · doi:10.1119/1.1934486 · Cited by 17,935
Atkins, E. (1978) · Physics Bulletin · doi:10.1088/0031-9112/29/12/034 · Cited by 7,110
Hench, L. L., & West, J. K. (1990) · Chemical Reviews · doi:10.1021/cr00099a003 · Cited by 4,450
Valden, M., Lai, X., & Goodman, D. W. (1998) · Science · doi:10.1126/science.281.5383.1647 · Cited by 4,136
Advances in the catalysis of Au nanoparticles
Haruta, M., & Daté, M. (2001) · Applied Catalysis A: General · doi:10.1016/s0926-860x(01)00847-x · Cited by 1,414
"Plugging into Enzymes": Nanowiring of Redox Enzymes by a Gold Nanoparticle
Xiao, Y., Patolsky, F., Katz, E., Hainfeld, J. F., & Willner, I. (2003) · Science · doi:10.1126/science.1080664 · Cited by 1,270
Seeding of Colloidal Au Nanoparticle Solutions. 2. Improved Control of Particle Size and Shape
Brown, K. R., Walter, D. G., & Natan, M. J. (2000) · Chemistry of Materials · doi:10.1021/cm980065p · Cited by 944
Electrical wiring of redox enzymes
Heller, A. (1990) · Accounts of Chemical Research · doi:10.1021/ar00173a002 · Cited by 788
Sol-gel encapsulation methods for biosensors
Dave, B. C., Dunn, B., Valentine, J. S., & Zink, J. I. (1994) · Analytical Chemistry · doi:10.1021/ac00094a001 · Cited by 683
Jia, J., Wang, B., Wu, A., Cheng, G., Li, Z., & Dong, S. (2002) · Analytical Chemistry · doi:10.1021/ac011116w · Cited by 653
Fluorescence-based glucose sensors
Pickup, J. C., Hussain, F., Evans, N. D., Rolinski, O. J., & Birch, D. J. S. (2005) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2004.10.002 · Cited by 616
Organic Chemistry within Ceramic Matrixes: Doped Sol-Gel Materials
Avnir, D. (1995) · Accounts of Chemical Research · doi:10.1021/ar00056a002 · Cited by 616
Nonenzymatic Glucose Detection Using Mesoporous Platinum
Park, S., Chung, T. D., & Kim, H. C. (2003) · Analytical Chemistry · doi:10.1021/ac0263465 · Cited by 594
Hydroxylamine Seeding of Colloidal Au Nanoparticles in Solution and on Surfaces
Brown, K. R., & Natan, M. J. (1998) · Langmuir · doi:10.1021/la970982u · Cited by 538
Core–Shell Assembled Nanoparticles as Catalysts
Zhong, C. J., & Maye, M. M. (2001) · Advanced Materials · doi:10.1002/1521-4095(200110)13:19<1507::aid-adma1507>3.0.co;2-# · Cited by 511
Photonic Crystal Carbohydrate Sensors: Low Ionic Strength Sugar Sensing
Asher, S. A., Alexeev, V. L., Goponenko, A. V., Sharma, A. C., Lednev, I. K., Wilcox, C. S., & Finegold, D. N. (2003) · Journal of the American Chemical Society · doi:10.1021/ja021037h · Cited by 488
Enzyme-Based Biosensors for in Vivo Measurements
Wilson, G. S., & Hu, Y. (2000) · Chemical Reviews · doi:10.1021/cr990003y · Cited by 434
Highly Ordered Platinum‐Nanotubule Arrays for Amperometric Glucose Sensing
Yuan, J. H., Wang, K., & Xia, X. H. (2005) · Advanced Functional Materials · doi:10.1002/adfm.200400321 · Cited by 432
Kinetics and mechanism of glucose electrooxidation on different electrode-catalysts
Vassilyev, Y. B., Khazova, O. A., & Nikolaeva, N. N. (1985) · Journal of Electroanalytical Chemistry and Interfacial Electrochemistry · doi:10.1016/0022-0728(85)85084-1 · Cited by 422
Gold nanoparticle arrays for the voltammetric sensing of dopamine
Raj, C. R., Okajima, T., & Ohsaka, T. (2003) · Journal of Electroanalytical Chemistry · doi:10.1016/s0022-0728(02)01481-x · Cited by 420
Self-citationArtificial Receptors as Chemosensors for Carbohydrates
James, T. D., & Shinkai, S. (2002) · Topics in Current Chemistry · doi:10.1007/3-540-45010-6_6 · Cited by 406
Russell, R. J., Pishko, M. V., Gefrides, C. C., McShane, M. J., & Coté, G. L. (1999) · Analytical Chemistry · doi:10.1021/ac990060r · Cited by 353
Shoji, E., & Freund, M. S. (2001) · Journal of the American Chemical Society · doi:10.1021/ja005906j · Cited by 343
Combinatorial Discovery of Alloy Electrocatalysts for Amperometric Glucose Sensors
Sun, Y., Buck, H., & Mallouk, T. E. (2001) · Analytical Chemistry · doi:10.1021/ac0015117 · Cited by 306
Brinker, C. J., & Scherer, G. W. (1990) · Sol-Gel Science · doi:10.1016/b978-0-08-057103-4.50013-1 · Cited by 287
Electrochemical oxidation of glucose on single crystal gold surfaces
Adžić, R. R., Hsiao, M. W., & Yeager, E. B. (1989) · Journal of Electroanalytical Chemistry · doi:10.1016/0022-0728(89)87164-5 · Cited by 255
Concentration dependence of the mechanism of glucose oxidation at gold electrodes in alkaline media
A. Larew, L., & Johnson, D. C. (1989) · Journal of Electroanalytical Chemistry and Interfacial Electrochemistry · doi:10.1016/0022-0728(89)80020-8 · Cited by 255
Nonenzymatic Glucose Detection by Using a Three‐Dimensionally Ordered, Macroporous Platinum Template
Song, Y., Zhang, D., Gao, W., & Xia, X. (2005) · Chemistry – A European Journal · doi:10.1002/chem.200400981 · Cited by 250
Electrical Wiring of Redox Enzymes
Heller, A. (1990) · Photochemical Conversion and Storage of Solar Energy · doi:10.1007/978-94-011-3396-8_5 · Cited by 247
Hsiao, M. W., Adžić, R. R., & Yeager, E. B. (1996) · Journal of The Electrochemical Society · doi:10.1149/1.1836536 · Cited by 240
Can continuous glucose monitoring be used for the treatment of diabetes?
Reach, G., & Wilson, G. S. (1992) · Analytical Chemistry · doi:10.1021/ac00030a001 · Cited by 235
Polyaniline/Gold Nanoparticle Multilayer Films: Assembly, Properties, and Biological Applications
Tian, S., Liu, J., Zhu, T., & Knoll, W. (2004) · Chemistry of Materials · doi:10.1021/cm049211j · Cited by 213
You, T., Niwa, O., Chen, Z., Hayashi, K., Tomita, M., & Hirono, S. (2003) · Analytical Chemistry · doi:10.1021/ac034204k · Cited by 199
Gold–platinum alloy nanoparticle assembly as catalyst for methanol electrooxidation
Lou, Y., Maye, M. M., Han, L., Luo, J., & Zhong, C.-J. (2001) · Chemical Communications · doi:10.1039/b008669j · Cited by 180
Core−Shell Gold Nanoparticle Assembly as Novel Electrocatalyst of CO Oxidation
Maye, M. M., Lou, Y., & Zhong, C.-J. (2000) · Langmuir · doi:10.1021/la000503i · Cited by 176
Electrochemical Reduction of Oxygen on Gold Nanoparticle-Electrodeposited Glassy Carbon Electrodes
El-Deab, M. S., Okajima, T., & Ohsaka, T. (2003) · Journal of The Electrochemical Society · doi:10.1149/1.1574806 · Cited by 168
In Vitro Diagnostics in Diabetes: Meeting the Challenge
Turner, A. P., Chen, B., & Piletsky, S. A. (1999) · Clinical Chemistry · doi:10.1093/clinchem/45.9.1596 · Cited by 161
Badugu, R., Lakowicz, J. R., & Geddes, C. D. (2003) · Analytical Chemistry · doi:10.1021/ac0303721 · Cited by 152
Burke, L. D. (2004) · Gold bulletin · doi:10.1007/bf03215520 · Cited by 136
Granot, E., Patolsky, F., & Willner, I. (2004) · The Journal of Physical Chemistry B · doi:10.1021/jp038004o · Cited by 112
Biocatalytic Carbon Paste Sensors Based on a Mediator Pasting Liquid
Lawrence, N. S., Deo, R. P., & Wang, J. (2004) · Analytical Chemistry · doi:10.1021/ac049943v · Cited by 86
Self-Assembled Silica Gel Networks
Wang, J., Pamidi, P. V. A., & Zanette, D. R. (1998) · Journal of the American Chemical Society · doi:10.1021/ja9742747 · Cited by 66
(2000) · doi:10.1002/1439-7641(20000804)1:1<18::aid-cphc18>3.0.co;2-l
Cited by
Gold Nanoparticles in Chemical and Biological Sensing
Saha, K., Agasti, S. S., Kim, C., Li, X., & Rotello, V. M. (2012) · Chemical Reviews · doi:10.1021/cr2001178 · Cited by 4,620
Electrochemical Non-enzymatic Glucose Sensors: A Perspective and an Evaluation
Toghill, K. E., & Compton, R. G. (2010) · International Journal of Electrochemical Science · doi:10.1016/s1452-3981(23)15359-4 · Cited by 926
A Review on Functionalized Gold Nanoparticles for Biosensing Applications
Zeng, S., Yong, K.-T., Roy, I., Dinh, X.-Q., Yu, X., & Luan, F. (2011) · Plasmonics · doi:10.1007/s11468-011-9228-1 · Cited by 754
Synthesis and electrochemical applications of gold nanoparticles
Guo, S., & Wang, E. (2007) · Analytica Chimica Acta · doi:10.1016/j.aca.2007.07.054 · Cited by 693
Jiang, L.-C., & Zhang, W.-D. (2010) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2009.10.038 · Cited by 667
Metadata
- Authors
- Jena, B. K., & Raj, C. R.
- Venue
- Chemistry – A European Journal
- Publisher
- Wiley
- Published
- 2006-03-10
- Volume
- 12
- Issue
- 10
- Pages
- 2702-2708
- ISSN
- 0947-6539 (ISSN-L)
- 1521-3765
- OpenAlex
- W2150827236
- Cited by
- 259
- References
- 43
- FWCI
- 15.86
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.